Division of Petroleum & Chemical Safety
Facility: 2010849 Tank: 5
Click for Facility/Tank Ownership history
Capacity:
560
Product:
Used Oil
Status:
Abandoned in place
Regulated Status
Federal
OSFM
First Notify Date:
7/23/1991
Current Age:
33
Install Date:
Last Used Date:
12/15/2009
Product Date:
6/13/1991
Petroleum Use:
CERCLA Substance:
CAS Code:
Removed Date:
Abandoned Material:
Inert material mixed with portland cement
Abandoned Date:
8/10/2017
Red Tag Issue Date:
Fee Due:
$0.00
UL Number
Equipment Information
Equipment Type
Equipment
Install Date
Last Passing Test Date
Test Expire Date
Failed Test Date
Corrosion Prot - Piping
Gravity Feed
7/8/2004
N/A
N/A
Corrosion Prot - Tank
STIP3 Cathodic Protection with Dielectric Coating
4/3/2009
N/A
Leak Detect - Piping
Gravity Feed
N/A
N/A
Leak Detect - Tank
110 - 600 gallons Manual Tank Gauging
N/A
N/A
Overfill Prev Device
Less than 25 gallon fills
N/A
N/A
Piping
Fiberglass Single Wall Piping
N/A
N/A
Spill Contain Device
Single Wall Spill Bucket
Tank
STIP3 Single Wall
N/A
N/A
Latest Blended Fuel Compatibility Form
No Compatibility Forms Listed
Additional Tests
No Additional Tests Listed