Division of Petroleum & Chemical Safety

 

Facility: 7046156 Tank: 1

Click for Facility/Tank Ownership history

Capacity: 15000
Product: E15
Status: Currently in use
Regulated Status Federal
OSFM First Notify Date: 9/20/2016
Current Age: 10
Install Date: 6/21/2016
Last Used Date:
Product Date: 6/21/2016
Petroleum Use:
CERCLA Substance:
CAS Code:
Removed Date:
Abandoned Material:
Abandoned Date:
Red Tag Issue Date:
Fee Due: $0.00
UL Number

Equipment Information

Equipment Type Equipment Install Date Last Passing Test Date Test Expire Date Failed Test Date
Corrosion Prot - Piping Fiberglass Non-Corrosive Not applicable Not applicable
Corrosion Prot - Tank Fiberglass Non-Corrosive Not applicable Not applicable
Leak Detect - Piping Mechanical Pressurized Line Leak Detection South 9/19/2019 9/3/2025 9/3/2026
Leak Detect - Piping Mechanical Pressurized Line Leak Detection North 9/3/2025 9/3/2026
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 450 Plus with CSLD 9/3/2025 9/3/2026
Leak Detect - Tank Non-Discriminating Interstitial Monitoring Sensors 9/3/2025 9/3/2026
Overfill Prev Device Overfill Drop Tube Valve 9/28/2021 9/4/2024 9/4/2027
Piping Fiberglass Double Wall Ameron Dualoy 3000/LCX Not applicable Not applicable
Piping Single Wall STP/Tanktop Sump South 9/4/2024 9/4/2027
Leak Detect - Piping Sump Sensor with positive shutdown 9/3/2025 9/3/2026
Piping Single Wall STP/Tanktop Sump North 9/4/2024 9/4/2027
Leak Detect - Piping Sump Sensor with positive shutdown 9/3/2025 9/3/2026
Spill Contain Device Double Wall Spill Bucket 9/4/2024 9/4/2027
Tank Fiberglass Double Wall XERXES Not applicable Not applicable

Failed test = the latest test has failed.

Not applicable = a test does not apply to this equipment type or configuration.

No passing test found = a passing test is expected but was not found from the source data.


Latest Blended Fuel Compatibility Form

File Name Status Status Date
CompatibilityFormSummary09092024-123342.pdf Approved 12/10/2024

Compatibility Form Attachments

File Name Description
577014-449-09_C.pdf ATG Probe
Encore_flex_fuel.pdf Dispenser
_assets_products_documents_1C-3112P_1C-3132P.pdf Double Wall Spill Bucket
xerxes (1).pdf Fiberglass Double Wall
NOV Fiber Glass Systems Piping compatibility-letters-11-07-2023.pdf Fiberglass Double Wall
18-10-Wirebraid-E0-E85.pdf Hose
FEPSTPMLD.pdf Mechanical Pressurized Line Leak Detection North
FEPSTPMLD.pdf Mechanical Pressurized Line Leak Detection South
Veeder Root Model 794380-208.pdf Non-Discriminating Interstitial Monitoring Sensors
Encore_flex_fuel.pdf Nozzle
opw-fuel-compatibility-matrix-below-ground-products-2018.pdf OPW
71SO_Overfill_Prevention_Valve.pdf Overfill Drop Tube Valve
opw-10-series-emergency-shut-off-valves-2018.pdf Shear Valve
opw-opw-61tp-tank-bottom-protector-2018.pdf Submersible Turbine Pump
opw-opw-61tp-tank-bottom-protector-2018.pdf Suction Pump
Veeder Root sump compatibility.pdf Sump Sensor with positive shutdown in Single Wall STP/Tanktop Sump North
Veeder Root sump compatibility.pdf Sump Sensor with positive shutdown in Single Wall STP/Tanktop Sump South
ZCL-XERXES-Sump-Brochure-web-16.pdf Xerxes

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date History
Piping Fiberglass Double Wall Ameron Dualoy 3000/LCX Precision Test (Piping) Pass 9/3/2025 Show History