Division of Petroleum & Chemical Safety

 

Facility: 2007054 Tank: 7

Click for Facility/Tank Ownership history

Capacity: 4000
Product: E85
Status: Currently in use
Regulated Status Federal
OSFM First Notify Date: 5/9/2013
Current Age: 12
Install Date: 10/26/2012
Last Used Date:
Product Date:
Petroleum Use:
CERCLA Substance:
CAS Code:
Removed Date:
Abandoned Material:
Abandoned Date:
Red Tag Issue Date:
Fee Due: $0.00
UL Number

Equipment Information

Equipment Type Equipment Install Date Last Passing Test Date Test Expire Date Failed Test Date
Corrosion Prot - Piping Fiberglass Non-Corrosive N/A N/A
Corrosion Prot - Tank Composite Non-Corrosive N/A N/A
Leak Detect - Piping Mechanical Pressurized Line Leak Detection 10/31/2024 10/31/2025
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 450 10/31/2024 10/31/2025
Leak Detect - Tank Non-Discriminating Interstitial Monitoring Sensors 1/7/2025 1/7/2026
Overfill Prev Device Overfill Drop Tube Valve 9/25/2023 9/25/2023 9/25/2026
Piping Fiberglass Double Wall Ameron N/A N/A
Piping Single Wall STP/Tanktop Sump 9/22/2023 9/22/2026
Leak Detect - Piping Sump Sensor with positive shutdown 12/27/2024 12/27/2025
Spill Contain Device Double Wall Spill Bucket 6/6/2023 7/3/2023 7/3/2026
Tank Composite Double Wall Modern Welding Glasteel 1 N/A N/A

Latest Blended Fuel Compatibility Form

File Name Status Status Date
CompatibilityFormSummary05242023-110746.pdf Approved 5/24/2023

Compatibility Form Attachments

File Name Description
e85 veeder probe.pdf ATG Probe
e85 veeder probe.pdf ATG Probe
E85 equipment approvals US Department of Energy.pdf Composite Double Wall composite tank
E85 equipment approvals US Department of Energy.pdf Composite Double Wall composite tank
Opw spill containers.pdf Double Wall Spill Bucket
e85 frp pipe.pdf Fiberglass Double Wall
e85 frp pipe.pdf Fiberglass Double Wall
e85 dope.pdf Gasoila E Seal
e85 dope.pdf Gasoila E Seal
e85 gilbarco.pdf Gilbarco
e85 gilbarco.pdf Gilbarco
E85 equipment approvals US Department of Energy.pdf Mechanical Pressurized Line Leak Detection
E85 equipment approvals US Department of Energy.pdf Mechanical Pressurized Line Leak Detection
e85 veeder sensor.pdf Non-Discriminating Interstitial Monitoring Sensors
e85 veeder sensor.pdf Non-Discriminating Interstitial Monitoring Sensors
e85 veeder sensor.pdf Non-Discriminating Sump Sensor with positive shutdown in Single Wall STP/Tanktop Sump
e85 veeder sensor.pdf Non-Discriminating Sump Sensor with positive shutdown in Single Wall STP/Tanktop Sump
Graco_ChemCompGuideEN-B.pdf Other Riser
e85 opw.pdf Overfill Drop Tube Valve
e85 opw.pdf Overfill Drop Tube Valve
e85 opw.pdf Single Wall Spill Bucket
e85 opw.pdf Single Wall STP/Tanktop Sump
e85 opw.pdf Single Wall STP/Tanktop Sump
e85 opw.pdf Single Wall UDC Sump
e85 opw.pdf Single Wall UDC Sump

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date History
Piping Fiberglass Double Wall Ameron Precision Test (Piping) Pass 7/3/2023 Show History