Information
JB Pritzker, Governor
James A. Rivera, State Fire Marshal
Division of Petroleum & Chemical Safety
State of Illinois
Employment Opportunities
Ready Illinois
Find us on Facebook
UST
Search
Contractor Search
Permit Search
Disclaimer & Rules/Statutes
Disclaimer
Rules
Statutes
Statistics & Reports
Statistics
Red Tag Tanks
Blended Fuel Tanks
Federal Energy Act Reports
Help
Division of Petroleum & Chemical Safety
Facility: 3001645 Tank: 2
Click for Facility/Tank Ownership history
Capacity:
500
Product:
Used Oil
Status:
Abandoned in place
Regulated Status
Federal
OSFM
First Notify Date:
2/26/1986
Current Age:
37
Install Date:
Last Used Date:
10/27/2015
Product Date:
Petroleum Use:
CERCLA Substance:
CAS Code:
Removed Date:
Abandoned Material:
Inert material mixed with portland cement
Abandoned Date:
6/16/2016
Red Tag Issue Date:
Fee Due:
$0.00
UL Number
Equipment Information
Equipment Type
Equipment
Install Date
Last Passing Test Date
Test Expire Date
Failed Test Date
Corrosion Prot - Piping
Sacrificial Anode Cathodic Protection
8/23/2013
N/A
Corrosion Prot - Tank
STIP3 Cathodic Protection with Dielectric Coating
8/23/2013
N/A
Leak Detect - Piping
Gravity Feed
N/A
N/A
Leak Detect - Tank
110 - 600 gallons Manual Tank Gauging
N/A
N/A
Overfill Prev Device
Less than 25 gallon fills
N/A
N/A
Piping
Steel Single Wall Piping
N/A
N/A
Spill Contain Device
Single Wall Spill Bucket
Tank
STIP3 Single Wall
N/A
N/A
Latest Blended Fuel Compatibility Form
No Compatibility Forms Listed
Additional Tests
No Additional Tests Listed
Previous Page