Division of Petroleum & Chemical Safety

 

Facility: 2010832 Tank: 9

Click for Facility/Tank Ownership history

Capacity: 10000
Product: E85
Status: Currently in use
Regulated Status Federal
OSFM First Notify Date: 12/31/1996
Current Age: 28
Install Date: 10/25/1996
Last Used Date:
Product Date: 10/25/1996
Petroleum Use:
CERCLA Substance:
CAS Code:
Removed Date:
Abandoned Material:
Abandoned Date:
Red Tag Issue Date:
Fee Due: $0.00
UL Number

Equipment Information

Equipment Type Equipment Install Date Last Passing Test Date Test Expire Date Failed Test Date
Corrosion Prot - Piping Fiberglass Non-Corrosive N/A N/A
Corrosion Prot - Tank Fiberglass Non-Corrosive N/A N/A
Leak Detect - Piping Electronic Pressurized Line Leak Detection 9/25/2024 9/25/2025
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 350R with CSLD 6/18/2024 9/25/2024 9/25/2025
Leak Detect - Tank Hydrostatic Reservoir Interstitial Monitoring Sensors 9/25/2024 9/25/2025
Overfill Prev Device Overfill Drop Tube Valve 6/18/2024 6/18/2024 6/18/2027
Piping Fiberglass Double Wall Ameron N/A N/A
Piping Single Wall STP/Tanktop Sump 8/7/2023 8/7/2026
Leak Detect - Piping Sump Sensor with positive shutdown 6/18/2024 9/25/2024 9/25/2025
Piping Single Wall Transition Sump 8/7/2023 8/7/2026
Leak Detect - Piping Sump Sensor with positive shutdown 6/18/2024 9/25/2024 9/25/2025
Spill Contain Device Single Wall Spill Bucket 8/7/2023 8/7/2026
Tank Fiberglass Brine Filled Double Wall N/A N/A

Latest Blended Fuel Compatibility Form

File Name Status Status Date
CompatibilityFormSummary06262024-112440.pdf Approved 6/26/2024

Compatibility Form Attachments

File Name Description
veeder root probes.pdf ATG Probe
veeder root probes.pdf ATG Probe
Morrison ball valve.pdf Ball Valves
wayne dispensers all.pdf Dispenser
wayne dispensers all.pdf Dispenser
veeder root plld.pdf Electronic Pressurized Line Leak Detection
veeder root plld.pdf Electronic Pressurized Line Leak Detection
containment solutions tanks & all products.pdf Fiberglass Brine Filled Double Wall
containment solutions tanks & all products.pdf Fiberglass Brine Filled Double Wall
ameron fiberglass pipe.pdf Fiberglass Double Wall
ameron fiberglass pipe.pdf Fiberglass Double Wall
opw-634-series-tight-fill-top-seal-caps-2018.pdf Fill Cap
opw-634-series-tight-fill-top-seal-caps-2018.pdf Fill Cap
hose master flex connectors.pdf Flex Connector Steel
Continental_Goodyear_flexsteel hoses.pdf Hose
Continental_Goodyear_flexsteel hoses.pdf Hose
veeder root sensors all.pdf Hydrostatic Reservoir Interstitial Monitoring Sensors
veeder root sensors all.pdf Hydrostatic Reservoir Interstitial Monitoring Sensors
opw-11bp-series-ethanol-nozzles_2018.pdf Nozzle
opw-11bp-series-ethanol-nozzles_2018.pdf Nozzle
FFS-0392 Defender Series OPV Datasheet.pdf Overfill Drop Tube Valve
opw e85 shear valve.pdf Shear Valve
opw e85 shear valve.pdf Shear Valve
franklin spill containers.pdf Single Wall Spill Bucket
franklin spill containers.pdf Single Wall Spill Bucket
containment solutions tanks & all products.pdf Single Wall STP/Tanktop Sump
containment solutions tanks & all products.pdf Single Wall STP/Tanktop Sump
containment solutions tanks & all products.pdf Single Wall Transition Sump
containment solutions tanks & all products.pdf Single Wall Transition Sump
Western-Fiberglass sumps & pipe.pdf Single Wall UDC Sump
Western-Fiberglass sumps & pipe.pdf Single Wall UDC Sump
Franklin.pdf Submersible Turbine Pump
Franklin.pdf Submersible Turbine Pump
veeder root sensors all.pdf Sump Sensor with positive shutdown
veeder root sensors all.pdf Sump Sensor with positive shutdown
gasoila dope.pdf Thread sealant
gasoila dope.pdf Thread sealant

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date History
Piping Fiberglass Double Wall Ameron Precision Test (Piping) Pass 9/25/2024 Show History