Division of Petroleum & Chemical Safety

 

Facility: 4046173 Tank: 6

Click for Facility/Tank Ownership history

Capacity: 20000
Product: B-99
Status: Currently in use
Regulated Status Federal
OSFM First Notify Date: 2/21/2017
Current Age: 7
Install Date: 9/23/2016
Last Used Date:
Product Date: 9/24/2017
Petroleum Use:
CERCLA Substance:
CAS Code:
Removed Date:
Abandoned Material:
Abandoned Date:
Red Tag Issue Date:
Fee Due: $0.00
UL Number

Equipment Information

Equipment Type Equipment Install Date Last Passing Test Date Test Expire Date Failed Test Date
Corrosion Prot - Piping Fiberglass Non-Corrosive N/A N/A
Corrosion Prot - Tank Fiberglass Non-Corrosive N/A N/A
Leak Detect - Piping Electronic Pressurized Line Leak Detection 8/15/2024 8/15/2025
Leak Detect - Tank Automatic Tank Gauging Incon TS 5000 with SCALD 2/12/2020 8/15/2024 8/15/2025
Leak Detect - Tank Non-Discriminating Interstitial Monitoring Sensors 8/15/2024 8/15/2025
Overfill Prev Device Overfill Alarm 8/15/2024 8/15/2027
Overfill Prev Device Overfill Drop Tube Valve 2/17/2023 8/15/2024 8/15/2027
Piping Fiberglass Double Wall Ameron Dualoy 3000/LCX N/A N/A
Piping Single Wall STP/Tanktop Sump 10/22/2019 10/17/2022 10/17/2025
Leak Detect - Piping Sump Sensor with positive shutdown 8/15/2024 8/15/2025
Piping Single Wall Transition Sump 10/22/2019 10/17/2022 10/17/2025
Leak Detect - Piping Sump Sensor with positive shutdown 8/15/2024 8/15/2025
Spill Contain Device Double Wall Spill Bucket 8/31/2022 8/31/2025
Tank Fiberglass Double Wall XERXES N/A N/A

Latest Blended Fuel Compatibility Form

File Name Status Status Date
CompatibilityFormSummary06062022-083937.pdf Approved 6/6/2022

Compatibility Form Attachments

File Name Description
Loves-768-LL3-LL2-ULS-DIS-B99+4-21-20 (1) B99.pdf ATG Probe
Loves-768-LL3-LL2-ULS-DIS-B99+4-21-20 (1) B99.pdf ATG Probe
below-ground-products-fuel-compatibility-matrix-2018.pdf Double Wall Spill Bucket
below-ground-products-fuel-compatibility-matrix-2018.pdf Double Wall Spill Bucket
LineLeakDetection B99 & E85.pdf Electronic Pressurized Line Leak Detection
LineLeakDetection B99 & E85.pdf Electronic Pressurized Line Leak Detection
Dualoy+3000+LCX+Data+Sheet B99 & E85.pdf Fiberglass Double Wall
Dualoy+3000+LCX+Data+Sheet B99 & E85.pdf Fiberglass Double Wall
MH9061 LABEL-Shawcor 3x7 B99 & E85.pdf Fiberglass Double Wall
MH9061 LABEL-Shawcor 3x7 B99 & E85.pdf Fiberglass Double Wall
Loves-LL3-LL2-ULS-DIS-B99+10-10-19 B99.pdf Non-Discriminating Interstitial Monitoring Sensors
Loves-LL3-LL2-ULS-DIS-B99+10-10-19 B99.pdf Non-Discriminating Interstitial Monitoring Sensors
Loves-768-LL3-LL2-ULS-DIS-B99+4-21-20 (1) B99.pdf Non-Discriminating Sump Sensor with positive shutdown in Single Wall STP/Tanktop Sump
Loves-768-LL3-LL2-ULS-DIS-B99+4-21-20 (1) B99.pdf Non-Discriminating Sump Sensor with positive shutdown in Single Wall STP/Tanktop Sump
Loves-768-LL3-LL2-ULS-DIS-B99+4-21-20 (1) B99.pdf Non-Discriminating Sump Sensor with positive shutdown in Single Wall Transition Sump
Loves-768-LL3-LL2-ULS-DIS-B99+4-21-20 (1) B99.pdf Non-Discriminating Sump Sensor with positive shutdown in Single Wall Transition Sump
Defender Overfill Prev. Valve B99 & E85.pdf Overfill Drop Tube Valve
FFS-0392 Defender Series OPV Datasheet B99.pdf Overfill Drop Tube Valve
Bravo_Sumps_AlternativeFuels_R3 B99 & E85.pdf Single Wall STP/Tanktop Sump
Bravo_Sumps_AlternativeFuels_R3 B99 & E85.pdf Single Wall STP/Tanktop Sump
Bravo_Sumps_AlternativeFuels_R3 B99 & E85.pdf Single Wall Transition Sump
Bravo_Sumps_AlternativeFuels_R3 B99 & E85.pdf Single Wall Transition Sump
FFS-0796 (60 Hz) 4HP Submersible Turbine Pumps Datasheet 4HP B99.pdf STP
FFS-0796 (60 Hz) 4HP Submersible Turbine Pumps Datasheet 4HP B99.pdf STP
Bravo_Sumps_AlternativeFuels_R3 B99 & E85.pdf UDC
Bravo_Sumps_AlternativeFuels_R3 B99 & E85.pdf UDC

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date History
Piping Fiberglass Double Wall Ameron Dualoy 3000/LCX Precision Test (Piping) Pass 8/15/2024 Show History