Division of Petroleum & Chemical Safety

 

Facility: 2040743 Tank: 1

Click for Facility/Tank Ownership history

Capacity: 15000
Product: Gasoline - Regular
Status: Currently in use
Regulated Status Federal
OSFM First Notify Date: 11/15/2002
Current Age: 23
Install Date: 8/15/2002
Last Used Date:
Product Date: 10/25/2002
Petroleum Use:
CERCLA Substance:
CAS Code:
Removed Date:
Abandoned Material:
Abandoned Date:
Red Tag Issue Date:
Fee Due: $0.00
UL Number

Equipment Information

Equipment Type Equipment Install Date Last Passing Test Date Test Expire Date Failed Test Date
Corrosion Prot - Piping Flexible Non-Corrosive Not applicable Not applicable
Corrosion Prot - Tank Fiberglass Non-Corrosive Not applicable Not applicable
Leak Detect - Piping Electronic Pressurized Line Leak Detection West 8/18/2025 8/18/2026
Leak Detect - Piping Electronic Pressurized Line Leak Detection East 8/18/2025 8/18/2026
Leak Detect - Tank Hydrostatic Reservoir Interstitial Monitoring Sensors with monitor 8/18/2025 8/18/2026
Overfill Prev Device Overfill Alarm 1/3/2022 8/18/2025 8/18/2028
Piping Fiberglass Double Wall Ameron Dualoy 3000/LCX 3/26/2025 Not applicable Not applicable
Piping Single Wall STP/Tanktop Sump 9/30/2020 8/10/2023 8/10/2026
Leak Detect - Piping Sump Sensor 8/18/2025 8/18/2026
Piping Single Wall Transition Sump East Center 8/10/2023 8/10/2026
Leak Detect - Piping Sump Sensor 8/18/2025 8/18/2026
Piping Single Wall Transition Sump West 8/10/2023 8/10/2026
Leak Detect - Piping Sump Sensor 8/18/2025 8/18/2026
Piping Single Wall Transition Sump East 9/30/2020 8/10/2023 8/10/2026
Leak Detect - Piping Sump Sensor 8/18/2025 8/18/2026
Piping Single Wall Transition Sump West Center 3/26/2025 3/26/2028
Leak Detect - Piping Sump Sensor 8/18/2025 8/18/2026
Spill Contain Device Single Wall Spill Bucket 8/10/2023 8/10/2026
Tank Fiberglass Double Wall Fluid Containment Brine Filled Not applicable Not applicable

Failed test = the latest test has failed.

Not applicable = a test does not apply to this equipment type or configuration.

No passing test found = a passing test is expected but was not found from the source data.


Latest Blended Fuel Compatibility Form

No Compatibility Forms Listed


Additional Tests

Equipment Type Equipment Test Type Test Result Test Date History
Piping Fiberglass Double Wall Ameron Dualoy 3000/LCX Precision Test (Piping) Pass 3/26/2025 Show History
Piping Flexible Double Wall Environ Geo Flex Precision Test (Piping) Pass 6/17/2022 Show History
Piping Flexible Double Wall Environ Geo Flex Precision Test (Piping) Fail 6/9/2022 Show History