Division of Petroleum & Chemical Safety

 
Pay Tank Fees Online Print Detail Page Export to Excel

Facility Details

Facility Number: 7047550
Status: Active
Facility Name: QT #7190
Address: 4501 Veterans Memorial Drive Mount Vernon, IL 62864
County: Jefferson
Property Parcel: 1002200010
Facility Type: Attended Self-Service Station
Owner Type: Private
Green Tag Decal: Y003419
Green Tag Issue Date: 10/5/2023
Green Tag Expiration Date: 12/31/2025

Owner Details

Owner Name: QuikTrip Corporation
Owner Address: 4705 South 129th East Ave. Tulsa, OK 74134
Owner Status: Current Owner
Purchase Date:
Type of Financial Responsibility: Commercial Insurance
Financial Responsibility Reporting Due Date: 4/11/2026

Motor Fuel Dispensing Permits

MFD Permit Type Issue Date Expiration Date
Self Service 10/5/2023 12/31/2025

Owner Summary

Click for Facility/Tank Ownership history
Owner Number Owner Name Owner Status Purchase Date
U0034559 QuikTrip Corporation, Current Owner

Permits (Unexpired)

Click for permit history

No Active Permits Found

Notice of Violatlions (Current)

NOV Number: E0020251621 (Pending)    Issue Date: 6/27/2025    Expiration Date: 8/26/2025    View NOV Form

Tanks Violations
Facility A/B operator retraining required as a result of issuance of the Notice of Violation
Facility Annual Emergency Stop Inspection not completed or inspection report not available. - Report is not completed, Facility has 7 E-Stops only 6 tested.
1, 2, 4, 5, 6, 7, 8 Line interstitial sensors have been raised and rendered inoperational. - Dispenser #17 raised sensor
6 Line leak detection equipment in alarm or failed test, must repair or replace. - L33 T6 DSL-Auto STP sump removed from programming.
2, 3, 4 Miscellaneous - 174.370 General Requirement to Maintain All Equipment
6 Miscellaneous - Spill prevention equipment device requires repair
Facility Missing copies of 30 day Walkthrough Inspection Report. - 2 years of records required.
Facility Missing copies of Annual Walkthrough Inspection Report.
1, 2, 3, 4, 5, 6, 7, 8 Monthly line interstitial sensor records not available. - Records must be available for the previous 2 years.
1, 2, 3, 4, 5, 6, 7, 8 Piping interstitial must be open in all sumps - Dispensers 2-18
6 Precision line test required. - Line leaking at T6 STP sump, repair leak, remove product and test the line.
1, 2, 3, 4, 5, 6, 7, 8 Required monthly tank interstitial sensor records not available. - Records must be available for the previous 2 years.

IEMA Numbers Associated with the Facility

No IEMA Numbers Found

LUST Fund Eligibility and Deductibility Determinations

No Applications Found

Pay Tank Fees Online

Tank Information

Tank Number Capacity Product Status Regulated Status Red Tag Issued Fee Due Abandon/Removal Date
1 20000 Gasoline - Regular Currently in use Federal $0.00
2 20000 Gasoline - Regular Currently in use Federal $0.00
3 20000 Gasoline - Non Ethanol Currently in use Federal $0.00
4 20000 Gasoline - Premium Currently in use Federal $0.00
5 18000 B-99 Currently in use Federal $0.00
6 30000 Diesel Fuel Currently in use Federal $0.00
7 30000 Diesel Fuel Currently in use Federal $0.00
8 30000 Diesel Fuel Currently in use Federal $0.00

Dispenser Information

Name\ID Status
1/2 Active
1/2 Diesel Active
2/3 Diesel Active
3/4 Active
3/4 Diesel Active
4/5 Diesel Active
5/6 Active
5/6 Diesel Active
6/7 Diesel Active
7/8 Active
9/10 Active
11/12 Active
13/14 Active
15/16 Active
17/18 Active
19/20 Active

MFD Motorfuel Dispensing Forms

Facility Number Name City Received Date Letter
7047550 QT #7190 Mount Vernon 09/21/2023 Letter Form