Notice of Violations (Current)
No Notice of Violations Found
IEMA Numbers Associated with the Facility
No IEMA Numbers Found
LUST
Fund Eligibility and Deductibility Determinations
No Applications Found
Tank Number 1
| Capacity: |
12000 |
|
Petroleum Use: |
|
| Product: |
Gasoline - Premium |
|
CERCLA Substance: |
|
| Status: |
Currently in use |
|
CAS Code: |
|
| Regulated Status: |
Federal |
|
Removed Date: |
|
|
OSFM
First Notify Date: |
12/31/2014 |
|
Abandoned Material: |
|
| Current Age: |
12 |
|
Abandoned Date: |
|
| Install Date: |
9/17/2014 |
|
Red Tag Issue Date: |
|
| Last Used Date: |
|
|
Fee Due: |
$0.00 |
| Product Date: |
9/18/2014 |
|
|
|
Equipment Information
| Equipment Type |
Equipment |
Last Passing Date |
Test Expire Date |
|
Corrosion Prot - Piping
|
Flexible Non-Corrosive |
Not applicable |
Not applicable |
|
Corrosion Prot - Tank
|
Fiberglass Non-Corrosive |
Not applicable |
Not applicable |
|
Leak Detect - Piping
|
Mechanical Pressurized Line Leak Detection |
4/6/2026 |
4/6/2027 |
|
Leak Detect - Tank
|
Automatic Tank Gauging Veeder Root TLS 350 Plus with CSLD |
4/6/2026 |
4/6/2027 |
|
Leak Detect - Tank
|
Non-Discriminating Interstitial Monitoring Sensors |
4/6/2026 |
4/6/2027 |
|
Overfill Prev Device
|
Overfill Alarm |
4/24/2025 |
4/24/2028 |
|
Overfill Prev Device
|
Overfill Drop Tube Valve |
8/11/2026 |
8/11/2029 |
|
Piping
|
Flexible Double Wall A.P.T. Poly Tech S175SC |
Not applicable |
Not applicable |
|
Piping
|
Single Wall STP/Tanktop Sump |
4/24/2025 |
4/24/2028 |
Leak Detect - Piping
|
Sump Sensor with positive shutdown |
4/24/2025 |
4/24/2028 |
|
Spill Contain Device
|
Double Wall Spill Bucket |
4/24/2025 |
4/24/2028 |
|
Tank
|
Fiberglass Double Wall XERXES |
Not applicable |
Not applicable |
|
Vent, Riser, Fill Piping
|
Steel risers |
Not applicable |
Not applicable |
Additional Tests
| Equipment Type |
Equipment |
Test Type |
Test Result |
Test Date |
|
Piping
|
Flexible Double Wall A.P.T. Poly Tech S175SC
|
Precision Test (Piping)
|
Pass
|
4/6/2026
|
Tank Number 2
| Capacity: |
20000 |
|
Petroleum Use: |
|
| Product: |
Gasoline - Regular |
|
CERCLA Substance: |
|
| Status: |
Currently in use |
|
CAS Code: |
|
| Regulated Status: |
Federal |
|
Removed Date: |
|
|
OSFM
First Notify Date: |
12/31/2014 |
|
Abandoned Material: |
|
| Current Age: |
12 |
|
Abandoned Date: |
|
| Install Date: |
9/17/2014 |
|
Red Tag Issue Date: |
|
| Last Used Date: |
|
|
Fee Due: |
$0.00 |
| Product Date: |
9/18/2014 |
|
|
|
Equipment Information
| Equipment Type |
Equipment |
Last Passing Date |
Test Expire Date |
|
Corrosion Prot - Piping
|
Flexible Non-Corrosive |
Not applicable |
Not applicable |
|
Corrosion Prot - Tank
|
Fiberglass Non-Corrosive |
Not applicable |
Not applicable |
|
Leak Detect - Piping
|
Mechanical Pressurized Line Leak Detection |
4/6/2026 |
4/6/2027 |
|
Leak Detect - Piping
|
Mechanical Pressurized Line Leak Detection |
4/6/2026 |
4/6/2027 |
|
Leak Detect - Tank
|
Automatic Tank Gauging Veeder Root TLS 350 Plus with CSLD |
4/6/2026 |
4/6/2027 |
|
Leak Detect - Tank
|
Non-Discriminating Interstitial Monitoring Sensors |
4/6/2026 |
4/6/2027 |
|
Overfill Prev Device
|
Overfill Alarm |
4/24/2025 |
4/24/2028 |
|
Overfill Prev Device
|
Overfill Drop Tube Valve |
8/11/2026 |
8/11/2029 |
|
Piping
|
Flexible Double Wall A.P.T. Poly Tech S175SC |
Not applicable |
Not applicable |
|
Piping
|
Single Wall STP/Tanktop Sump |
4/24/2025 |
4/24/2028 |
Leak Detect - Piping
|
Sump Sensor with positive shutdown |
4/24/2025 |
4/24/2028 |
|
Spill Contain Device
|
Double Wall Spill Bucket |
4/24/2025 |
4/24/2028 |
|
Tank
|
Fiberglass Double Wall XERXES |
Not applicable |
Not applicable |
|
Vent, Riser, Fill Piping
|
Steel risers |
Not applicable |
Not applicable |
Additional Tests
| Equipment Type |
Equipment |
Test Type |
Test Result |
Test Date |
|
Piping
|
Flexible Double Wall A.P.T. Poly Tech S175SC
|
Precision Test (Piping)
|
Pass
|
4/6/2026
|
Tank Number 3
| Capacity: |
20000 |
|
Petroleum Use: |
|
| Product: |
B-99 |
|
CERCLA Substance: |
|
| Status: |
Currently in use |
|
CAS Code: |
|
| Regulated Status: |
Federal |
|
Removed Date: |
|
|
OSFM
First Notify Date: |
12/31/2014 |
|
Abandoned Material: |
|
| Current Age: |
12 |
|
Abandoned Date: |
|
| Install Date: |
9/17/2014 |
|
Red Tag Issue Date: |
|
| Last Used Date: |
|
|
Fee Due: |
$0.00 |
| Product Date: |
9/18/2014 |
|
|
|
Equipment Information
| Equipment Type |
Equipment |
Last Passing Date |
Test Expire Date |
|
Corrosion Prot - Piping
|
Fiberglass Non-Corrosive |
Not applicable |
Not applicable |
|
Corrosion Prot - Tank
|
Fiberglass Non-Corrosive |
Not applicable |
Not applicable |
|
Leak Detect - Piping
|
European with No Test Req Suction |
Not applicable |
Not applicable |
|
Leak Detect - Tank
|
Non-Discriminating Interstitial Monitoring Sensors With Monitor |
4/6/2026 |
4/6/2027 |
|
Overfill Prev Device
|
Overfill Alarm |
4/24/2025 |
4/24/2028 |
|
Overfill Prev Device
|
Overfill Drop Tube Valve |
8/11/2026 |
8/11/2029 |
|
Piping
|
Fiberglass Double Wall Ameron Dualoy 3000/LCX |
Not applicable |
Not applicable |
|
Piping
|
Single Wall STP/Tanktop Sump |
Not applicable |
Not applicable |
Leak Detect - Piping
|
Piping Sump Sensors Not Regulated |
4/24/2025 |
Not applicable |
|
Piping
|
Single Wall STP/Tanktop Sump |
Not applicable |
Not applicable |
Leak Detect - Piping
|
Piping Sump Sensors Not Regulated |
4/24/2025 |
Not applicable |
|
Spill Contain Device
|
Double Wall Spill Bucket |
4/24/2025 |
4/24/2028 |
|
Tank
|
Fiberglass Double Wall XERXES |
Not applicable |
Not applicable |
|
Vent, Riser, Fill Piping
|
Steel risers |
Not applicable |
Not applicable |
Additional Tests
| Equipment Type |
Equipment |
Test Type |
Test Result |
Test Date |
|
Piping
|
Fiberglass Double Wall Ameron Dualoy 3000/LCX
|
Precision Test (Piping)
|
Pass
|
4/6/2026
|
|
Piping
|
Flexible Double Wall A.P.T. Poly Tech S175SC
|
Precision Test (Piping)
|
Pass
|
12/28/2023
|
|
Tank
|
Fiberglass Double Wall XERXES
|
Precision Test (Tank)
|
Pass
|
4/6/2026
|
Tank Number 4
| Capacity: |
20000 |
|
Petroleum Use: |
|
| Product: |
B-11 |
|
CERCLA Substance: |
|
| Status: |
Currently in use |
|
CAS Code: |
|
| Regulated Status: |
Federal |
|
Removed Date: |
|
|
OSFM
First Notify Date: |
12/31/2014 |
|
Abandoned Material: |
|
| Current Age: |
12 |
|
Abandoned Date: |
|
| Install Date: |
9/17/2014 |
|
Red Tag Issue Date: |
|
| Last Used Date: |
|
|
Fee Due: |
$0.00 |
| Product Date: |
9/18/2014 |
|
|
|
Equipment Information
| Equipment Type |
Equipment |
Last Passing Date |
Test Expire Date |
|
Corrosion Prot - Piping
|
Fiberglass Non-Corrosive |
Not applicable |
Not applicable |
|
Corrosion Prot - Tank
|
Fiberglass Non-Corrosive |
Not applicable |
Not applicable |
|
Leak Detect - Piping
|
Mechanical Pressurized Line Leak Detection |
9/8/2026 |
9/8/2027 |
|
Leak Detect - Piping
|
Mechanical Pressurized Line Leak Detection |
9/8/2026 |
9/8/2027 |
|
Leak Detect - Tank
|
Automatic Tank Gauging Veeder Root TLS 350 Plus with CSLD |
4/6/2026 |
4/6/2027 |
|
Leak Detect - Tank
|
Non-Discriminating Interstitial Monitoring Sensors |
4/6/2026 |
4/6/2027 |
|
Overfill Prev Device
|
Overfill Alarm |
4/24/2025 |
4/24/2028 |
|
Overfill Prev Device
|
Overfill Drop Tube Valve |
8/11/2026 |
8/11/2029 |
|
Piping
|
Fiberglass Double Wall Ameron Dualoy 3000/LCX |
Not applicable |
Not applicable |
|
Piping
|
Single Wall STP/Tanktop Sump |
4/24/2025 |
4/24/2028 |
Leak Detect - Piping
|
Sump Sensor with positive shutdown |
4/24/2025 |
4/24/2028 |
|
Spill Contain Device
|
Double Wall Spill Bucket |
4/24/2025 |
4/24/2028 |
|
Tank
|
Fiberglass Double Wall XERXES |
Not applicable |
Not applicable |
|
Vent, Riser, Fill Piping
|
Steel risers |
Not applicable |
Not applicable |
Additional Tests
| Equipment Type |
Equipment |
Test Type |
Test Result |
Test Date |
|
Piping
|
Fiberglass Double Wall Ameron Dualoy 3000/LCX
|
Precision Test (Piping)
|
Pass
|
4/6/2026
|
|
Piping
|
Flexible Double Wall A.P.T. Poly Tech S175SC
|
Precision Test (Piping)
|
Pass
|
12/28/2023
|
|
Tank
|
Fiberglass Double Wall XERXES
|
Precision Test (Tank)
|
Pass
|
4/6/2026
|
|
Leak Detect - Tank
|
SIR and Prec Tightness Testing Warren Rogers Assoc. Petro Network S3 Version D
|
Precision Test (Tank)
|
Pass
|
11/15/2020
|
Tank Number 5
| Capacity: |
20000 |
|
Petroleum Use: |
|
| Product: |
B-11 |
|
CERCLA Substance: |
|
| Status: |
Currently in use |
|
CAS Code: |
|
| Regulated Status: |
Federal |
|
Removed Date: |
|
|
OSFM
First Notify Date: |
12/31/2014 |
|
Abandoned Material: |
|
| Current Age: |
12 |
|
Abandoned Date: |
|
| Install Date: |
9/17/2014 |
|
Red Tag Issue Date: |
|
| Last Used Date: |
|
|
Fee Due: |
$0.00 |
| Product Date: |
9/18/2014 |
|
|
|
Equipment Information
| Equipment Type |
Equipment |
Last Passing Date |
Test Expire Date |
|
Corrosion Prot - Piping
|
Fiberglass Non-Corrosive |
Not applicable |
Not applicable |
|
Corrosion Prot - Tank
|
Fiberglass Non-Corrosive |
Not applicable |
Not applicable |
|
Leak Detect - Piping
|
Mechanical Pressurized Line Leak Detection |
9/8/2026 |
9/8/2027 |
|
Leak Detect - Piping
|
Mechanical Pressurized Line Leak Detection |
9/8/2026 |
9/8/2027 |
|
Leak Detect - Tank
|
Automatic Tank Gauging Veeder Root TLS 350 Plus with CSLD |
4/6/2026 |
4/6/2027 |
|
Leak Detect - Tank
|
Non-Discriminating Interstitial Monitoring Sensors |
4/6/2026 |
4/6/2027 |
|
Overfill Prev Device
|
Overfill Alarm |
4/24/2025 |
4/24/2028 |
|
Overfill Prev Device
|
Overfill Drop Tube Valve |
8/11/2026 |
8/11/2029 |
|
Piping
|
Blending Sump |
4/24/2025 |
4/24/2028 |
Leak Detect - Piping
|
Sump Sensor with positive shutdown |
4/24/2025 |
4/24/2028 |
|
Piping
|
Fiberglass Double Wall Ameron Dualoy 3000/LCX |
Not applicable |
Not applicable |
|
Piping
|
Single Wall STP/Tanktop Sump |
4/24/2025 |
4/24/2028 |
Leak Detect - Piping
|
Sump Sensor with positive shutdown |
4/24/2025 |
4/24/2028 |
|
Spill Contain Device
|
Double Wall Spill Bucket |
4/24/2025 |
4/24/2028 |
|
Tank
|
Fiberglass Double Wall XERXES |
Not applicable |
Not applicable |
|
Vent, Riser, Fill Piping
|
Steel risers |
Not applicable |
Not applicable |
Additional Tests
| Equipment Type |
Equipment |
Test Type |
Test Result |
Test Date |
|
Piping
|
Fiberglass Double Wall Ameron Dualoy 3000/LCX
|
Precision Test (Piping)
|
Pass
|
4/6/2026
|
|
Piping
|
Flexible Double Wall A.P.T. Poly Tech S175SC
|
Precision Test (Piping)
|
Pass
|
12/28/2023
|
|
Tank
|
Fiberglass Double Wall XERXES
|
Precision Test (Tank)
|
Pass
|
4/6/2026
|
|
Leak Detect - Tank
|
SIR and Prec Tightness Testing Warren Rogers Assoc. Petro Network S3 Version D
|
Precision Test (Tank)
|
Pass
|
11/15/2020
|
Tank Number 6
| Capacity: |
12000 |
|
Petroleum Use: |
|
| Product: |
Diesel Exhaust Fluid (Non-Regulated) |
|
CERCLA Substance: |
|
| Status: |
Unknown |
|
CAS Code: |
|
| Regulated Status: |
Non-Regulated |
|
Removed Date: |
|
|
OSFM
First Notify Date: |
|
|
Abandoned Material: |
|
| Current Age: |
12 |
|
Abandoned Date: |
|
| Install Date: |
9/17/2014 |
|
Red Tag Issue Date: |
|
| Last Used Date: |
|
|
Fee Due: |
|
| Product Date: |
|
|
|
|
Equipment Information
| Equipment Type |
Equipment |
Last Passing Date |
Test Expire Date |
|
Corrosion Prot - Piping
|
Flexible Non-Corrosive |
Not applicable |
Not applicable |
|
Corrosion Prot - Tank
|
Fiberglass Non-Corrosive |
Not applicable |
Not applicable |
|
Leak Detect - Piping
|
Mechanical Pressurized Line Leak Detection |
No passing test found |
No passing test found |
|
Leak Detect - Piping
|
Sump Sensor |
No passing test found |
No passing test found |
|
Leak Detect - Tank
|
Automatic Tank Gauging Veeder Root TLS 350 |
No passing test found |
No passing test found |
|
Leak Detect - Tank
|
Non-Discriminating Interstitial Monitoring Sensors |
No passing test found |
No passing test found |
|
Overfill Prev Device
|
Overfill Alarm |
No passing test found |
No passing test found |
|
Overfill Prev Device
|
Overfill Drop Tube Valve |
No passing test found |
No passing test found |
|
Piping
|
Flexible Double Wall A.P.T. Poly Tech S175SC |
Not applicable |
Not applicable |
|
Spill Contain Device
|
Double Wall Spill Bucket |
No passing test found |
No passing test found |
|
Tank
|
Fiberglass Double Wall XERXES |
Not applicable |
Not applicable |
|
Vent, Riser, Fill Piping
|
Steel risers |
Not applicable |
Not applicable |
Additional Tests
No Tests Listed
Failed test = the latest test has failed.
Not applicable = a test does not apply to this equipment type or configuration.
No passing test found = a passing test is expected but was not found from the source data.
MFD
Motorfuel Dispensing Forms
No Forms Found