Division of Petroleum & Chemical Safety

 

Facility Details

Facility Number: 7044864
Status: Active
Facility Name: Ninkasi Beverage Group, LLC d/b/a Marketplace - Shell
Address: 2301 Reed Station Parkway Carbondale, IL 62901
County: Jackson
Property Parcel: 15-13-126-006
Facility Type: Attended Self-Service Station
Owner Type: Private
Green Tag Decal: Y004245
Green Tag Issue Date: 9/5/2023
Green Tag Expiration Date: 12/31/2025

Owner Details

Owner Name: Ninkasi Investment, LLC
Owner Address: 514 S. Illinois Ave. Carbondale, IL 62901
Owner Status: Current Owner
Purchase Date: 8/29/2018
Type of Financial Responsibility: Commercial Insurance
Financial Responsibility Reporting Due Date: 12/12/2023

Motor Fuel Dispensing Permits

MFD Permit Type Issue Date Expiration Date
Self Service 5/24/2023 12/31/2025

Owner Summary

Click for Facility/Tank Ownership history
Owner Number Owner Name Owner Status Purchase Date
U0039280 Ninkasi Investment, LLC Current Owner 8/29/2018
U0036053 HBA Development Former Owner

Permits (Unexpired)

Click for permit history

No Active Permits Found

Notice of Violatlions (Current)

NOV Number: E0020252091 (Pending)    Issue Date: 8/14/2025    Expiration Date: 10/13/2025    View NOV Form

Tanks Violations
Facility Facility Operation and Maintenance Plan not completed or available. - Template available at www.sfm.illinois.gov
Facility Financial responsibility must be reported yearly - Financial Responsibility must be declared annually. The form can be found at https://webapps.sfm.illinois.gov/USTPortal/Forms/FinancialResponsibility.
1, 2, 3, 4 Line interstitial sensors have been raised and rendered inoperational. - All STP sump sensors raised. Dispensers 3/4, 5/6, 7/8, 11/12, 15/16
Facility Missing copies of 30 day Walkthrough Inspection Report. - 30 day inspection is required to be completed by an A/B Operator.
Facility Missing copies of current testing certificates for operator training - No Class C operator onsite during inspection, certificates are missing or expired in the compliance binder provided.
Facility Missing copy of emergency instructions or emergency procedures plan - Template in binder is blank.
Facility Missing list of designated Class A/B & C Operators - Update list.
1, 2, 3, 4 Monthly line interstitial sensor records not available. - 2 years of records are required to be maintained.
1, 2, 3, 4 Piping sump tested triennially using low level positive shut off option. Sump does not meet low level test requirements. See remarks. Perform standard hydrostatic test on sump. - STP sumps require standard hydrostatic test due to the violations. Dispensers 1/2 3/4, 5/6, 7/8, 11/12, 15/16,(sumps are cracked).
1, 2, 3, 4 Required monthly tank interstitial sensor records not available. - 2 years of records are required to be maintained.
2 Tank monitor does not appear to function properly and requires maintenance. - Premium gasoline high water alarm, no water found with paste, repair tank monitor.
1, 2, 4 Water in containment with required interstitial sensors - Remove water and repair containments to prevent water ingress. - STP sumps are full of liquid. Dispenser sumps are cracked and piping backfill has migrated into sumps, repair containments and perform a standard hydrostatic test following the repairs.

NOV Number: E0020252092 (Pending)    Issue Date: 8/14/2025    Expiration Date: 10/13/2025    View NOV Form

Tanks Violations
Facility Code complying instruction/warning signs are not properly mounted at each dispenser island - Minimum Signage. Signs shall be provided that are clearly visible to all self-service customers. The signs shall be made of all-weather material and the lettering shall be not less than ? inch high. The top of the signs shall be mounted no higher than 10 feet above grade, or at a height approved by OSFM, and shall include the following wording, at a minimum: 1) "Warning"; 2) "Stop Engine"; 3) "No Smoking"; 4) "Persons fueling vehicles shall remain with their vehicle, at the nozzle, while fueling is in progress"; 5) "It is unlawful and dangerous for anyone to dispense gasoline into unapproved containers".
Facility Fire Extinguishers - Past due for annual testing
Facility LP gas storage lacks proper collision protection or a 40" measurement from cabinet to a 5" raised sidewalk

IEMA Numbers Associated with the Facility

No IEMA Numbers Found

LUST Fund Eligibility and Deductibility Determinations

No Applications Found

Pay Tank Fees Online

Tank Information



Tank Number 1

Capacity: 20000 Petroleum Use:
Product: Gasoline - Regular CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 7/12/2011 Abandoned Material:
Current Age: 14 Abandoned Date:
Install Date: 7/8/2011 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date:

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Fiberglass Non-Corrosive N/A N/A
Corrosion Prot - Tank Fiberglass Non-Corrosive N/A N/A
Leak Detect - Piping Electronic Pressurized Line Leak Detection 2/4/2025 2/4/2026
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 450 with CSLD 2/4/2025 2/4/2026
Leak Detect - Tank Non-Discriminating Interstitial Monitoring Sensors 2/4/2025 2/4/2026
Overfill Prev Device Overfill Drop Tube Valve 2/4/2025 2/4/2028
Piping Fiberglass Double Wall Ameron N/A N/A
Piping Single Wall STP/Tanktop Sump 2/4/2025 2/4/2028
Leak Detect - Piping Sump Sensor with positive shutdown 2/4/2025 2/4/2026
Spill Contain Device Single Wall Spill Bucket 2/4/2025 2/4/2028
Tank Fiberglass Double Wall XERXES N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Fiberglass Double Wall Ameron Precision Test (Piping) Pass 2/4/2025



Tank Number 2

Capacity: 6000 Petroleum Use:
Product: Gasoline - Premium CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 7/12/2011 Abandoned Material:
Current Age: 14 Abandoned Date:
Install Date: 7/8/2011 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date:

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Fiberglass Non-Corrosive N/A N/A
Corrosion Prot - Tank Fiberglass Non-Corrosive N/A N/A
Leak Detect - Piping Electronic Pressurized Line Leak Detection 2/4/2025 2/4/2026
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 450 with CSLD 2/4/2025 2/4/2026
Leak Detect - Tank Non-Discriminating Interstitial Monitoring Sensors 2/4/2025 2/4/2026
Overfill Prev Device Overfill Drop Tube Valve 2/4/2025 2/4/2028
Piping Fiberglass Double Wall Ameron N/A N/A
Piping Single Wall STP/Tanktop Sump 2/4/2025 2/4/2028
Leak Detect - Piping Sump Sensor with positive shutdown 2/4/2025 2/4/2026
Spill Contain Device Single Wall Spill Bucket 2/4/2025 2/4/2028
Tank Fiberglass Double Wall XERXES N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Fiberglass Double Wall Ameron Precision Test (Piping) Pass 2/4/2025



Tank Number 3

Capacity: 8000 Petroleum Use:
Product: Diesel Fuel CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 7/12/2011 Abandoned Material:
Current Age: 14 Abandoned Date:
Install Date: 7/8/2011 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date:

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Fiberglass Non-Corrosive N/A N/A
Corrosion Prot - Tank Fiberglass Non-Corrosive N/A N/A
Leak Detect - Piping Electronic Pressurized Line Leak Detection 2/4/2025 2/4/2026
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 450 with CSLD 2/4/2025 2/4/2026
Leak Detect - Tank Non-Discriminating Interstitial Monitoring Sensors 2/4/2025 2/4/2026
Overfill Prev Device Overfill Drop Tube Valve 2/4/2025 2/4/2028
Piping Fiberglass Double Wall Ameron N/A N/A
Piping Single Wall STP/Tanktop Sump 2/4/2025 2/4/2028
Leak Detect - Piping Sump Sensor with positive shutdown 2/4/2025 2/4/2026
Spill Contain Device Single Wall Spill Bucket 2/4/2025 2/4/2028
Tank Fiberglass Double Wall XERXES N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Fiberglass Double Wall Ameron Precision Test (Piping) Pass 2/4/2025



Tank Number 4

Capacity: 6000 Petroleum Use:
Product: Gasoline - Non Ethanol CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 7/12/2011 Abandoned Material:
Current Age: 14 Abandoned Date:
Install Date: 7/8/2011 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date:

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Fiberglass Non-Corrosive N/A N/A
Corrosion Prot - Tank Fiberglass Non-Corrosive N/A N/A
Leak Detect - Piping Electronic Pressurized Line Leak Detection 2/4/2025 2/4/2026
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 450 with CSLD 2/4/2025 2/4/2026
Leak Detect - Tank Non-Discriminating Interstitial Monitoring Sensors 2/4/2025 2/4/2026
Overfill Prev Device Overfill Drop Tube Valve 2/4/2025 2/4/2028
Piping Fiberglass Double Wall Ameron N/A N/A
Piping Single Wall STP/Tanktop Sump 2/4/2025 2/4/2028
Leak Detect - Piping Sump Sensor with positive shutdown 2/4/2025 2/4/2026
Spill Contain Device Single Wall Spill Bucket 2/4/2025 2/4/2028
Tank Fiberglass Double Wall XERXES N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Fiberglass Double Wall Ameron Precision Test (Piping) Pass 2/4/2025

Dispenser Information



Name\ID 1/2

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 2/4/2025 2/4/2028
Leak Detect - Piping Sump Sensor with positive shutdown 2/4/2025 2/4/2026



Name\ID 11/12

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 2/4/2025 2/4/2028
Leak Detect - Piping Sump Sensor with positive shutdown 2/4/2025 2/4/2026



Name\ID 13/14

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 2/4/2025 2/4/2028
Leak Detect - Piping Sump Sensor with positive shutdown 2/4/2025 2/4/2026



Name\ID 15/16

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 2/4/2025 2/4/2028
Leak Detect - Piping Sump Sensor with positive shutdown 2/4/2025 2/4/2026



Name\ID 3/4

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 2/4/2025 2/4/2028
Leak Detect - Piping Sump Sensor with positive shutdown 2/4/2025 2/4/2026



Name\ID 5/6

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 2/4/2025 2/4/2028
Leak Detect - Piping Sump Sensor with positive shutdown 2/4/2025 2/4/2026



Name\ID 7/8

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 2/4/2025 2/4/2028
Leak Detect - Piping Sump Sensor with positive shutdown 2/4/2025 2/4/2026



Name\ID 9/10

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 2/4/2025 2/4/2028
Leak Detect - Piping Sump Sensor with positive shutdown 2/4/2025 2/4/2026

MFD Motorfuel Dispensing Forms

No Forms Found