Division of Petroleum & Chemical Safety

 

Facility Details

Facility Number: 7044570
Status: Active
Facility Name: Transportation Realty, Inc.
Address: 601 Halfway Rd. 603 Christian Court Marion, IL 62959
County: Williamson
Property Parcel: 06-14-301-002
Facility Type: Trucking Company
Owner Type: Private
Green Tag Decal: Z001089
Green Tag Issue Date: 10/16/2024
Green Tag Expire Date: 12/31/2026
MFD Type: Fleet

Owner Details

Owner Name: Transportation Realty, Inc. (Parent Corp.)
Owner Address: One Race Horse Drive East St. Louis, IL 622051001
Owner Status: Current Owner
Purchase Date: 4/7/2010
Type of Financial Responsibility: Commercial Insurance
Financial Responsibility Reporting Due Date: 12/1/2026

Owner Summary

Click for Facility/Tank Ownership history
Owner Number Owner Name Owner Status Purchase Date
U0035329 Transportation Realty, Inc. (Parent Corp.) Current Owner 4/7/2010

Permits (Unexpired)

Click for permit history

No Active Permits Found

Notice of Violations (Current)

NOV Number: E0020262015 (Pending)    Issue Date: 8/7/2026    Expiration Date: 10/6/2026    View NOV Form

Tanks Violations
Facility More than one dispensing island at an Unattended or Fleet facility; Emergency Shutoff Switch not provided for each dispensing island - The three islands must have an emergency stop located at each dispenser.

NOV Number: E0020262016 (Pending)    Issue Date: 8/7/2026    Expiration Date: 10/6/2026    View NOV Form

Tanks Violations
1 Dispensers - hoses cracked, split or worn and require replacement
Facility Emergency contact information for A/B & C Operators not posted at unmanned facility
1 Line interstitial sensors have been raised and rendered inoperational. - Dispenser sensors raised. Must be located on the bottom at the lowest point of the containment.
1 Miscellaneous - Each emergency stop shall be identified by a sign on all-weather materials stating "EMERGENCY STOP" in 2 inch red capital letters.
1 Open electrical conduit or junction boxes. - East STP sump electical junction box requries repair.
1 Piping interstitial must be open in all sumps
1 Spill prevention equipment contains liquid/debris and must be cleared of materials and maintained clean and dry.

IEMA Numbers Associated with the Facility

No IEMA Numbers Found

LUST Fund Eligibility and Deductibility Determinations

No Applications Found

Pay Tank Fees Online

Tank Information



Tank Number 1

Capacity: 20000 Petroleum Use:
Product: Diesel Fuel CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 8/2/2010 Abandoned Material:
Current Age: 16 Abandoned Date:
Install Date: 7/29/2010 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date:

Equipment Information

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Flexible Non-Corrosive Not applicable Not applicable
Corrosion Prot - Tank Composite Non-Corrosive Not applicable Not applicable
Leak Detect - Piping Electronic Pressurized Line Leak Detection 7/17/2026 7/17/2027
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 350 Plus 7/17/2026 7/17/2027
Leak Detect - Tank Non-Discriminating Interstitial Monitoring Sensors 7/17/2026 7/17/2027
Overfill Prev Device Overfill Drop Tube Valve 7/22/2025 7/22/2028
Piping Flexible Double Wall A.P.T. Poly Tech P175SC Not applicable Not applicable
Piping Single Wall STP/Tanktop Sump 7/22/2025 7/22/2028
Leak Detect - Piping Sump Sensor with positive shutdown 7/22/2025 7/22/2028
Piping Single Wall STP/Tanktop Sump 7/22/2025 7/22/2028
Leak Detect - Piping Sump Sensor with positive shutdown 7/22/2025 7/22/2028
Spill Contain Device Single Wall Spill Bucket 7/22/2025 7/22/2028
Tank Composite Double Wall Modern Welding Glasteel II Not applicable Not applicable

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Flexible Double Wall A.P.T. Poly Tech P175SC Precision Test (Piping) Pass 7/17/2026

Failed test = the latest test has failed.

Not applicable = a test does not apply to this equipment type or configuration.

No passing test found = a passing test is expected but was not found from the source data.


Dispenser Information



Name\ID 1

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 7/22/2025 7/22/2028
Leak Detect - Piping Sump Sensor with positive shutdown 7/17/2026 7/17/2027



Name\ID 1 Sat/2

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 7/22/2025 7/22/2028
Leak Detect - Piping Sump Sensor with positive shutdown 7/17/2026 7/17/2027



Name\ID 2 Sat/3

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 7/22/2025 7/22/2028
Leak Detect - Piping Sump Sensor with positive shutdown 7/17/2026 7/17/2027



Name\ID 3 Sat

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 7/22/2025 7/22/2028
Leak Detect - Piping Sump Sensor with positive shutdown 7/17/2026 7/17/2027

Failed test = the latest test has failed.

Not applicable = a test does not apply to this equipment type or configuration.

No passing test found = a passing test is expected but was not found from the source data.


MFD Motorfuel Dispensing Forms