Division of Petroleum & Chemical Safety

 

Facility Details

Facility Number: 7044368
Status: Active
Facility Name: Beelman Ready-Mix
Address: 5780 State Route 154 Pinckneyville, IL 62274
County: Perry
Property Parcel:
Facility Type: Trucking Company
Owner Type: Private
Green Tag Decal: Y003428
Green Tag Issue Date: 7/20/2023
Green Tag Expiration Date: 12/31/2025

Owner Details

Owner Name: Transportation Realty, Inc. (Parent Corp.)
Owner Address: One Race Horse Drive East St. Louis, IL 622051001
Owner Status: Current Owner
Purchase Date:
Type of Financial Responsibility: Commercial Insurance
Financial Responsibility Reporting Due Date: 12/11/2025

Motor Fuel Dispensing Permits

MFD Permit Type Issue Date Expiration Date
Fleet 7/20/2023 12/31/2025

Owner Summary

Click for Facility/Tank Ownership history
Owner Number Owner Name Owner Status Purchase Date
U0035329 Transportation Realty, Inc. (Parent Corp.) Current Owner

Permits (Unexpired)

Click for permit history

No Active Permits Found

Notice of Violatlions (Current)

NOV Number: E0020251718 (Pending)    Issue Date: 7/8/2025    Expiration Date: 9/6/2025    View NOV Form

Tanks Violations
1 Annual electronic line leak detector test not completed.
Facility Annual Emergency Stop Inspection not completed or inspection report not available.
1 Annual leak detection certification not completed (Required annually).
1 Line interstitial sensor functional test not accomplished (Required annually).
Facility Missing copies of Annual Walkthrough Inspection Report.
1 Overfill prevention equipment inspection(s) not completed (Required every 3 years).
1 Piping interstitial must be open in all sumps
1 Shear valve inspection report not completed (Required during Annual Walkthrough Inspection).
1 Tank interstitial sensor functional test not accomplished (Required annually.).
1 Triennial spill prevention equipment testing not completed.
1 Triennial testing for qualifying piping containment sump not completed (Required every 3 years).

IEMA Numbers Associated with the Facility

No IEMA Numbers Found

LUST Fund Eligibility and Deductibility Determinations

No Applications Found

Pay Tank Fees Online

Tank Information



Tank Number 1

Capacity: 20000 Petroleum Use:
Product: Diesel Fuel CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 8/26/2009 Abandoned Material:
Current Age: 16 Abandoned Date:
Install Date: 7/13/2009 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date:

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Flexible Non-Corrosive N/A N/A
Corrosion Prot - Tank Composite Non-Corrosive N/A N/A
Leak Detect - Piping Electronic Pressurized Line Leak Detection 7/16/2025 7/16/2026
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 350 7/16/2025 7/16/2026
Leak Detect - Tank Non-Discriminating Interstitial Monitoring Sensors 7/16/2025 7/16/2026
Overfill Prev Device Overfill Drop Tube Valve 7/16/2025 7/16/2028
Piping Flexible Double Wall A.P.T. Poly Tech S175SC N/A N/A
Piping Single Wall STP/Tanktop Sump 7/16/2025 7/16/2028
Leak Detect - Piping Sump Sensor 7/16/2025 7/16/2026
Piping Single Wall STP/Tanktop Sump 7/16/2025 7/16/2028
Leak Detect - Piping Sump Sensor 7/16/2025 7/16/2026
Spill Contain Device Single Wall Spill Bucket 7/16/2025 7/16/2028
Tank Composite Double Wall Modern Welding Glasteel II N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Flexible Double Wall A.P.T. Poly Tech S175SC Precision Test (Piping) Pass 6/6/2023

Dispenser Information



Name\ID 1/2

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 7/16/2025 7/16/2028
Leak Detect - Piping Sump Sensor 7/16/2025 7/16/2026



Name\ID 1S

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 7/16/2025 7/16/2028
Leak Detect - Piping Sump Sensor 7/16/2025 7/16/2026



Name\ID 2S

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 7/16/2025 7/16/2028
Leak Detect - Piping Sump Sensor 7/16/2025 7/16/2026

MFD Motorfuel Dispensing Forms

No Forms Found