Division of Petroleum & Chemical Safety

 

Facility Details

Facility Number: 7041178
Status: Active
Facility Name: Murphy Oil USA (Wal-Mart)
Address: 1348 I-1 Highway 1 (West Main) Carmi, IL 62821
County: White
Property Parcel: 13-22-400-007
Facility Type: Attended Self-Service Station
Owner Type: Private
Green Tag Decal: Z003814
Green Tag Issue Date: 9/25/2024
Green Tag Expire Date: 12/31/2026
MFD Type: Self Service

Owner Details

Owner Name: Murphy Oil USA, Inc.
Owner Address: 200 E. Peach Street El Dorado, AR 71730
Owner Status: Current Owner
Purchase Date:
Type of Financial Responsibility: Self-Insurance
Financial Responsibility Reporting Due Date: 10/1/2027

Owner Summary

Click for Facility/Tank Ownership history
Owner Number Owner Name Owner Status Purchase Date
U0029289 Murphy Oil USA, Inc. Current Owner

Permits (Unexpired)

Click for permit history

No Active Permits Found

Notice of Violations (Current)

NOV Number: E0020262119 (Pending)    Issue Date: 8/20/2026    Expiration Date: 10/19/2026    View NOV Form

Tanks Violations
1, 3 Line interstitial sensors have been raised and rendered inoperational. - Dispenser sumps, #7/8, 5/6, 3/4
3 Line leak detection equipment in alarm or failed test, must repair or replace. - Premium STP (L7) Alarm; sump is full of water.
Facility Missing copies of 30 day Walkthrough Inspection Report. - 30 day Walkthrough inspection not completed by A/B Operator since June 2026.
Facility Missing copies of current testing certificates for operator training - Dawn Piercy, C Operator Certificate is expired.
Facility Operator training course taken not approved by the Office of the Illinois State Fire Marshal - 360Training.com is not approved by OSFM.
1, 2, 3 Piping interstitial must be open in all sumps - Dispensers 7/8, 5/6, 3/4, 1/2, Regular unleaded North STP sump, Premium STP sump.
3 Water in containment with required interstitial sensors - Remove water and repair containments to prevent water ingress. - Premium STP sump is full of water.

IEMA Numbers Associated with the Facility

No IEMA Numbers Found

LUST Fund Eligibility and Deductibility Determinations

No Applications Found

Pay Tank Fees Online

Tank Information



Tank Number 1

Capacity: 15000 Petroleum Use:
Product: Gasoline - Regular CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 9/27/2002 Abandoned Material:
Current Age: 23 Abandoned Date:
Install Date: 7/25/2002 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 10/15/2002

Equipment Information

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Flexible Non-Corrosive Not applicable Not applicable
Corrosion Prot - Tank Fiberglass Non-Corrosive Not applicable Not applicable
Leak Detect - Piping Mechanical Pressurized Line Leak Detection 7/10/2026 7/10/2027
Leak Detect - Piping Mechanical Pressurized Line Leak Detection 7/10/2026 7/10/2027
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 350 7/10/2026 7/10/2027
Leak Detect - Tank Non-Discriminating Interstitial Monitoring Sensors 7/10/2026 7/10/2027
Overfill Prev Device Overfill Drop Tube Valve 9/27/2024 9/27/2027
Piping Flexible Double Wall Environ Geo Flex Not applicable Not applicable
Piping Single Wall STP/Tanktop Sump 8/19/2026 8/19/2029
Leak Detect - Piping Sump Sensor with positive shutdown 8/19/2026 8/19/2029
Piping Single Wall STP/Tanktop Sump 8/19/2026 8/19/2029
Leak Detect - Piping Sump Sensor 8/19/2026 8/19/2029
Spill Contain Device Double Wall Spill Bucket 8/4/2025 8/4/2028
Tank Fiberglass Double Wall Containment Solutions Not applicable Not applicable

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Flexible Double Wall Environ Geo Flex Precision Test (Piping) Pass 7/10/2026



Tank Number 2

Capacity: 8000 Petroleum Use:
Product: B-11 CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 9/27/2002 Abandoned Material:
Current Age: 23 Abandoned Date:
Install Date: 7/25/2002 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 10/15/2002

Equipment Information

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Flexible Non-Corrosive Not applicable Not applicable
Corrosion Prot - Tank Fiberglass Non-Corrosive Not applicable Not applicable
Leak Detect - Piping Mechanical Pressurized Line Leak Detection 7/10/2026 7/10/2027
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 350 7/10/2026 7/10/2027
Leak Detect - Tank Non-Discriminating Interstitial Monitoring Sensors 7/10/2026 7/10/2027
Overfill Prev Device Overfill Drop Tube Valve 9/27/2024 9/27/2027
Piping Flexible Double Wall Environ Geo Flex Not applicable Not applicable
Piping Single Wall STP/Tanktop Sump 8/19/2026 8/19/2029
Leak Detect - Piping Sump Sensor 8/19/2026 8/19/2029
Spill Contain Device Single Wall Spill Bucket 8/4/2025 8/4/2028
Tank Fiberglass Double Wall Containment Solutions Not applicable Not applicable

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Flexible Double Wall Environ Geo Flex Precision Test (Piping) Pass 7/10/2026



Tank Number 3

Capacity: 7000 Petroleum Use:
Product: Gasoline - Premium CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 9/27/2002 Abandoned Material:
Current Age: 23 Abandoned Date:
Install Date: 7/25/2002 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 10/15/2002

Equipment Information

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Flexible Non-Corrosive Not applicable Not applicable
Corrosion Prot - Tank Fiberglass Non-Corrosive Not applicable Not applicable
Leak Detect - Piping Mechanical Pressurized Line Leak Detection 7/10/2026 7/10/2027
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 350 7/10/2026 7/10/2027
Leak Detect - Tank Non-Discriminating Interstitial Monitoring Sensors 7/10/2026 7/10/2027
Overfill Prev Device Overfill Drop Tube Valve 11/11/2025 11/11/2028
Piping Flexible Double Wall Environ Geo Flex Not applicable Not applicable
Piping Single Wall STP/Tanktop Sump 8/19/2026 8/19/2029
Leak Detect - Piping Sump Sensor 8/19/2026 8/19/2029
Spill Contain Device Double Wall Spill Bucket 11/11/2025 11/11/2028
Tank Fiberglass Double Wall Containment Solutions Not applicable Not applicable

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Flexible Double Wall Environ Geo Flex Precision Test (Piping) Pass 7/10/2026

Failed test = the latest test has failed.

Not applicable = a test does not apply to this equipment type or configuration.

No passing test found = a passing test is expected but was not found from the source data.


Dispenser Information



Name\ID 1/2

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 8/19/2026 8/19/2029
Leak Detect - Piping Sump Sensor 7/10/2026 7/10/2027



Name\ID 3/4

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 8/19/2026 8/19/2029
Leak Detect - Piping Sump Sensor 7/10/2026 7/10/2027



Name\ID 5/6

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 9/12/2023 8/19/2026
Leak Detect - Piping Sump Sensor 7/10/2026 7/10/2027



Name\ID 7/8

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 9/12/2023 9/12/2026
Leak Detect - Piping Sump Sensor 7/10/2026 7/10/2027

Failed test = the latest test has failed.

Not applicable = a test does not apply to this equipment type or configuration.

No passing test found = a passing test is expected but was not found from the source data.


MFD Motorfuel Dispensing Forms

No Forms Found