Division of Petroleum & Chemical Safety

 

Facility Details

Facility Number: 7039708
Status: Active
Facility Name: KBJ's C-Store (Jayvira Corporation, Inc.)
Address: 10894 Bridgeport Rd. Bridgeport, IL 62417
County: Lawrence
Property Parcel: 06-000-628-10
Facility Type: Attended Self-Service Station
Owner Type: Private
Green Tag Decal: Z001741
Green Tag Issue Date: 5/7/2024
Green Tag Expire Date: 12/31/2026
MFD Type: Self Service

Owner Details

Owner Name: J & K 2017 Investments, Inc.
Owner Address: 10894 Bridgeport Road Bridgeport, IL 62417
Owner Status: Current Owner
Purchase Date: 3/2/2017
Type of Financial Responsibility: Commercial Insurance
Financial Responsibility Reporting Due Date: 5/14/2027

Owner Summary

Click for Facility/Tank Ownership history
Owner Number Owner Name Owner Status Purchase Date
U0041531 J & K 2017 Investments, Inc. Current Owner 3/2/2017
U0039064 Patel, Jagruti Former Owner 5/1/2017
U0034234 L E Anderson Bros. Oil, Inc. Former Owner 8/9/2000
U0000619 L.E. Anderson Brothers Oil Company, Inc. Former Owner 6/8/2000
U0029463 Bell, Chuck Former Owner 6/8/2000
U0035804 Patel, Vikram Kumar Former Owner
U0033836 Kirit Former Owner

Permits (Unexpired)

Click for permit history

No Active Permits Found

Notice of Violations (Current)

No Notice of Violations Found

IEMA Numbers Associated with the Facility

IEMA Number Inspection Date Inspection Type Permit Number
2025-0387 7/2/2025 Abandonment Log 00784-2025ABN

LUST Fund Eligibility and Deductibility Determinations

IEMA Number Status OSFM Received Date OSFM Response Date Deductible Letter
20250387 Eligible 7/23/2025 7/24/2025 $5,000 Letter
Pay Tank Fees Online

Tank Information



Tank Number 1

Capacity: 10000 Petroleum Use:
Product: Gasoline CERCLA Substance:
Status: Removed CAS Code:
Regulated Status: Federal Removed Date: 6/20/2000
OSFM First Notify Date: 8/10/2000 Abandoned Material:
Current Age: 0 Abandoned Date:
Install Date: 6/8/2000 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date:

Equipment Information

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Flexible Non-Corrosive Not applicable Not applicable
Corrosion Prot - Tank Fiberglass Non-Corrosive Not applicable Not applicable
Leak Detect - Piping Mechanical Pressurized Line Leak Detection No passing test found No passing test found
Leak Detect - Piping Sump Sensor No passing test found No passing test found
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 350 with CSLD No passing test found No passing test found
Overfill Prev Device Ball Float Vent Valve OPW 53 No passing test found No passing test found
Piping Flexible Double Wall Total Containment Omniflex II Not applicable Not applicable
Spill Contain Device Single Wall Spill Bucket No passing test found No passing test found
Tank Fiberglass Single Wall Not applicable Not applicable

Additional Tests

No Tests Listed




Tank Number 2

Capacity: 10000 Petroleum Use:
Product: Gasoline CERCLA Substance:
Status: Removed CAS Code:
Regulated Status: Federal Removed Date: 6/20/2000
OSFM First Notify Date: 8/10/2000 Abandoned Material:
Current Age: 0 Abandoned Date:
Install Date: 6/8/2000 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date:

Equipment Information

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Flexible Non-Corrosive Not applicable Not applicable
Corrosion Prot - Tank Fiberglass Non-Corrosive Not applicable Not applicable
Leak Detect - Piping Mechanical Pressurized Line Leak Detection No passing test found No passing test found
Leak Detect - Piping Sump Sensor No passing test found No passing test found
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 350 with CSLD No passing test found No passing test found
Overfill Prev Device Ball Float Vent Valve OPW 53 No passing test found No passing test found
Piping Flexible Double Wall Total Containment Omniflex II Not applicable Not applicable
Spill Contain Device Single Wall Spill Bucket No passing test found No passing test found
Tank Fiberglass Single Wall Not applicable Not applicable

Additional Tests

No Tests Listed




Tank Number 3

Capacity: 10000 Petroleum Use:
Product: Diesel Fuel CERCLA Substance:
Status: Removed CAS Code:
Regulated Status: Federal Removed Date: 6/20/2000
OSFM First Notify Date: 8/10/2000 Abandoned Material:
Current Age: 0 Abandoned Date:
Install Date: 6/8/2000 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date:

Equipment Information

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Flexible Non-Corrosive Not applicable Not applicable
Corrosion Prot - Tank Fiberglass Non-Corrosive Not applicable Not applicable
Leak Detect - Piping Mechanical Pressurized Line Leak Detection No passing test found No passing test found
Leak Detect - Piping Sump Sensor No passing test found No passing test found
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 350 with CSLD No passing test found No passing test found
Overfill Prev Device Ball Float Vent Valve OPW 53 No passing test found No passing test found
Piping Flexible Double Wall Total Containment Omniflex II Not applicable Not applicable
Spill Contain Device Single Wall Spill Bucket No passing test found No passing test found
Tank Fiberglass Single Wall Not applicable Not applicable

Additional Tests

No Tests Listed




Tank Number 4

Capacity: 10000 Petroleum Use:
Product: Gasoline - Regular CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 8/10/2000 Abandoned Material:
Current Age: 26 Abandoned Date:
Install Date: 6/26/2000 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 6/26/2000

Equipment Information

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Flexible Non-Corrosive Not applicable Not applicable
Corrosion Prot - Tank Fiberglass Non-Corrosive Not applicable Not applicable
Leak Detect - Piping Mechanical Pressurized Line Leak Detection 5/29/2026 5/29/2027
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 350 with CSLD 5/29/2026 5/29/2027
Overfill Prev Device Overfill Drop Tube Valve 5/28/2025 5/28/2028
Piping Flexible Double Wall OPW Flexworks Not applicable Not applicable
Piping Single Wall STP/Tanktop Sump 5/28/2025 5/28/2028
Leak Detect - Piping Sump Sensor with positive shutdown 5/28/2025 5/28/2028
Spill Contain Device Double Wall Spill Bucket 5/28/2025 5/28/2028
Tank Fiberglass Single Wall Not applicable Not applicable
Vent, Riser, Fill Piping Steel risers Not applicable Not applicable

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Flexible Double Wall OPW Flexworks Precision Test (Piping) Pass 5/29/2026



Tank Number 5

Capacity: 10000 Petroleum Use:
Product: Gasoline - Premium CERCLA Substance:
Status: Abandoned in place CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 8/10/2000 Abandoned Material: Inert material mixed with portland cement
Current Age: 26 Abandoned Date: 7/2/2025
Install Date: 6/26/2000 Red Tag Issue Date:
Last Used Date: 9/1/2024 Fee Due: $0.00
Product Date: 6/26/2000

Equipment Information

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Flexible Non-Corrosive Not applicable Not applicable
Corrosion Prot - Tank Fiberglass Non-Corrosive Not applicable Not applicable
Leak Detect - Piping Mechanical Pressurized Line Leak Detection 1/23/2024 1/23/2025
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 350 with CSLD 5/28/2025 5/28/2026
Overfill Prev Device Overfill Drop Tube Valve 5/17/2022 5/17/2025
Piping Flexible Double Wall OPW Flexworks Not applicable Not applicable
Piping Single Wall STP/Tanktop Sump 5/17/2022 5/17/2025
Leak Detect - Piping Sump Sensor with positive shutdown 5/17/2022 5/17/2025
Spill Contain Device Double Wall Spill Bucket 5/17/2022 5/17/2025
Tank Fiberglass Single Wall Not applicable Not applicable
Vent, Riser, Fill Piping Steel risers Not applicable Not applicable

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Flexible Double Wall OPW Flexworks Precision Test (Piping) Pass 1/23/2024
Tank Fiberglass Single Wall Precision Test (Tank) Fail 5/28/2025



Tank Number 6

Capacity: 10000 Petroleum Use: None
Product: Diesel Fuel CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 8/10/2000 Abandoned Material:
Current Age: 26 Abandoned Date:
Install Date: 6/26/2000 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 6/26/2000

Equipment Information

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Flexible Non-Corrosive Not applicable Not applicable
Corrosion Prot - Tank Fiberglass Non-Corrosive Not applicable Not applicable
Leak Detect - Piping Mechanical Pressurized Line Leak Detection 5/29/2026 5/29/2027
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 350 with CSLD 5/29/2026 5/29/2027
Overfill Prev Device Overfill Drop Tube Valve 5/28/2025 5/28/2028
Piping Flexible Double Wall OPW Flexworks Not applicable Not applicable
Piping Single Wall STP/Tanktop Sump 5/28/2025 5/28/2028
Leak Detect - Piping Sump Sensor with positive shutdown 5/28/2025 5/28/2028
Spill Contain Device Double Wall Spill Bucket 5/28/2025 5/28/2028
Tank Fiberglass Single Wall Not applicable Not applicable
Vent, Riser, Fill Piping Steel risers Not applicable Not applicable

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Flexible Double Wall OPW Flexworks Precision Test (Piping) Pass 5/29/2026

Failed test = the latest test has failed.

Not applicable = a test does not apply to this equipment type or configuration.

No passing test found = a passing test is expected but was not found from the source data.


Dispenser Information



Name\ID 1/2

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 5/28/2025 5/28/2028
Leak Detect - Piping Sump Sensor with positive shutdown 5/29/2026 5/29/2027



Name\ID 3/4

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 5/28/2025 5/28/2028
Leak Detect - Piping Sump Sensor with positive shutdown 5/29/2026 5/29/2027



Name\ID 5/6

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 5/28/2025 5/28/2028
Leak Detect - Piping Sump Sensor with positive shutdown 5/29/2026 5/29/2027



Name\ID 7/8

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 5/28/2025 5/28/2028
Leak Detect - Piping Sump Sensor with positive shutdown 5/29/2026 5/29/2027



Name\ID 9

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 5/28/2025 5/28/2028
Leak Detect - Piping Sump Sensor with positive shutdown 5/29/2026 5/29/2027



Name\ID Sat

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 5/28/2025 5/28/2028
Leak Detect - Piping Sump Sensor with positive shutdown 5/29/2026 5/29/2027

Failed test = the latest test has failed.

Not applicable = a test does not apply to this equipment type or configuration.

No passing test found = a passing test is expected but was not found from the source data.


MFD Motorfuel Dispensing Forms

No Forms Found