Division of Petroleum & Chemical Safety

 

Facility Details

Facility Number: 7036308
Status: Closed
Facility Name: Jonesboro One Stop
Address: 101 Broad St.
Jonesboro, IL 62952
County: Union
Property Parcel:
Facility Type: Attended Self-Service Station
Owner Type: Private
Green Tag Decal: S002821
Green Tag Issue Date: 6/15/2017
Green Tag Expiration Date: 12/31/2019

Owner Details

Owner Name: Krishna OM, LLC
Owner Address: 147 W. Vienna Street
Anna, IL 62906
Owner Status: Current Owner
Purchase Date: 12/20/2012
Type of Financial Responsibility: Commercial Insurance
Financial Responsibility Reporting Due Date: 6/15/2018

Motor Fuel Dispensing Permits

MFD Permit Type Issue Date Expiration Date
Self Service 6/15/2017 12/31/2019

Owner Summary

Click for Facility/Tank Ownership history
Owner Number Owner Name Owner Status Purchase Date
U0036876 Krishna OM, LLC Current Owner 12/20/2012
U0034044 Alchemist USA, LLC Former Owner 2/21/2007
U0015667 Veach Oil Company Former Owner 3/12/1998
U0035328 Ruby Enterprises Former Owner

Permits (Unexpired)

Click for permit history

No Active Permits Found

Notice of Violations (Current)

No Notice of Violations Found

IEMA Numbers Associated with the Facility

IEMA Number Inspection Date Inspection Type Permit Number
20-0184 4/1/2020 Removal Log 00356-2020REM

LUST Fund Eligibility and Deductibility Determinations

IEMA Number Status OSFM Received Date OSFM Response Date Deductible Letter
20200184 Eligible 5/18/2020 5/20/2020 $5,000 Letter
Pay Tank Fees Online

Tank Information



Tank Number 1

Capacity: 10000 Petroleum Use:
Product: Gasoline - Regular CERCLA Substance:
Status: Removed CAS Code:
Regulated Status: Federal Removed Date: 4/1/2020
OSFM First Notify Date: 5/14/1998 Abandoned Material:
Current Age: 22 Abandoned Date:
Install Date: 3/12/1998 Red Tag Issue Date:
Last Used Date: 4/18/2019 Fee Due: $0.00
Product Date: 3/12/1998

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Flexible Non-Corrosive N/A N/A
Corrosion Prot - Tank Fiberglass Non-Corrosive N/A N/A
Leak Detect - Piping European with No Test Req Suction N/A N/A
Leak Detect - Tank Automatic Tank Gauging Incon TS 1000 with SCALD
Overfill Prev Device Overfill Drop Tube Valve
Piping Flexible Double Wall N/A N/A
Piping Single Wall STP/Tanktop Sump
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Installed N/A N/A
Spill Contain Device Single Wall Spill Bucket
Tank Composite Single Wall ACT 100 N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date



Tank Number 2

Capacity: 2000 Petroleum Use:
Product: Diesel Fuel CERCLA Substance:
Status: Removed CAS Code:
Regulated Status: Federal Removed Date: 4/1/2020
OSFM First Notify Date: 5/14/1998 Abandoned Material:
Current Age: 22 Abandoned Date:
Install Date: 3/12/1998 Red Tag Issue Date:
Last Used Date: 4/18/2019 Fee Due: $0.00
Product Date: 3/12/1998

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Flexible Non-Corrosive N/A N/A
Corrosion Prot - Tank Fiberglass Non-Corrosive N/A N/A
Leak Detect - Piping European with No Test Req Suction N/A N/A
Leak Detect - Tank Automatic Tank Gauging Incon TS 1000 with SCALD
Overfill Prev Device Overfill Drop Tube Valve
Piping Flexible Double Wall N/A N/A
Piping Single Wall STP/Tanktop Sump
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Installed N/A N/A
Spill Contain Device Single Wall Spill Bucket
Tank Composite Single Wall ACT 100 N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date

Dispenser Information



Name\ID 1/2

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Installed N/A N/A



Name\ID 3/4

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Installed N/A N/A

MFD Motorfuel Dispensing Forms