Division of Petroleum & Chemical Safety

 

Facility Details

Facility Number: 7035861
Status: Active
Facility Name: Lake Zone Phillips 66
Address: 14711 State Hwy 37 Whittington, IL 62897
County: Franklin
Property Parcel: 03-19-276-003
Facility Type: Attended Self-Service Station
Owner Type: Private
Green Tag Decal: Y000606
Green Tag Issue Date: 1/26/2023
Green Tag Expiration Date: 12/31/2025

Owner Details

Owner Name: I Khodal, LLC
Owner Address: 14711 State Hwy 37 Whittington, IL 62897
Owner Status: Current Owner
Purchase Date: 11/19/2018
Type of Financial Responsibility: Certificate of Deposit
Financial Responsibility Reporting Due Date: 1/15/2026

Motor Fuel Dispensing Permits

MFD Permit Type Issue Date Expiration Date
Self Service 1/26/2023 12/31/2025

Owner Summary

Click for Facility/Tank Ownership history
Owner Number Owner Name Owner Status Purchase Date
U0039671 I Khodal, LLC Current Owner 11/19/2018
U0026115 Venturi Group Inc Former Owner 8/5/1997

Permits (Unexpired)

Click for permit history
Permit Number Type Status OSFM Receive Date Issue Date Expiration Date Documents
00511-2025REM Removal Approved / Issued 4/30/2025 4/30/2025 10/30/2025 Documents
00562-2025UPG Upgrade Approved / Issued 5/8/2025 5/8/2025 11/10/2025 Documents

Notice of Violatlions (Current)

NOV Number: E0020251485 (Pending)    Issue Date: 6/10/2025    Expiration Date: 8/9/2025    View NOV Form

Tanks Violations
1, 2 Line interstitial sensor functional test not accomplished (Required annually). - All piping sumps and sensors are regulated due to multiple upgrades.
Facility Miscellaneous - Emergency stop at all control stations shall be conspicuously marked and readily accessible to the attendant. Each emergency stop shall be identified by a sign on all-weather materials stating "EMERGENCY STOP" in 2 inch red capital letters. (Section 175.210)
Facility Missing copies of 30 day Walkthrough Inspection Report.
1, 2 Piping interstitial must be open in all sumps
1, 2 Triennial testing for qualifying piping containment sump not completed (Required every 3 years). - All piping sumps and sensors are regulated due to multiple upgrades.

NOV Number: E0020251486 (Pending)    Issue Date: 6/10/2025    Expiration Date: 8/9/2025    View NOV Form

Tanks Violations
Facility Farthest dispenser is greater than 40' and site lacks a communication system or system is inoperable
Facility Miscellaneous - All dispensing units shall be readily visible from the control station without assistive devices.

IEMA Numbers Associated with the Facility

No IEMA Numbers Found

LUST Fund Eligibility and Deductibility Determinations

IEMA Number Status OSFM Received Date OSFM Response Date Deductible Letter
15-0329 Eligible 7/6/2015 7/7/2015 $5,000
Pay Tank Fees Online

Tank Information



Tank Number 1

Capacity: 12000 Petroleum Use:
Product: Gasoline - Regular CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 12/1/1997 Abandoned Material:
Current Age: 27 Abandoned Date:
Install Date: 8/5/1997 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 8/15/1997

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Flexible Non-Corrosive N/A N/A
Corrosion Prot - Tank Composite Non-Corrosive N/A N/A
Leak Detect - Piping Mechanical Pressurized Line Leak Detection 8/9/2024 8/9/2025
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 350 8/9/2024 8/9/2025
Overfill Prev Device Ball Float Vent Valve OPW 53 8/18/2022 8/18/2025
Piping Flexible Double Wall N/A N/A
Piping Single Wall STP/Tanktop Sump
Leak Detect - Piping Sump Sensor with positive shutdown
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Installed N/A N/A
Spill Contain Device Single Wall Spill Bucket 8/18/2022 8/18/2025
Tank Composite Single Wall N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Flexible Double Wall Precision Test (Piping) Pass 8/9/2024



Tank Number 2

Capacity: 8000 Petroleum Use:
Product: Gasoline - Premium CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 12/1/1997 Abandoned Material:
Current Age: 27 Abandoned Date:
Install Date: 8/5/1997 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 8/15/1997

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Flexible Non-Corrosive N/A N/A
Corrosion Prot - Tank Composite Non-Corrosive N/A N/A
Leak Detect - Piping Mechanical Pressurized Line Leak Detection 8/9/2024 8/9/2025
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 350 8/9/2024 8/9/2025
Overfill Prev Device Ball Float Vent Valve OPW 53 8/18/2022 8/18/2025
Piping Flexible Double Wall N/A N/A
Piping Single Wall STP/Tanktop Sump
Leak Detect - Piping Sump Sensor with positive shutdown
Leak Detect - Piping Non-Discriminating Sump Sensor 6/25/2020 6/25/2021
Leak Detect - Piping Piping Sump Sensors Not Regulated N/A N/A
Spill Contain Device Single Wall Spill Bucket 8/18/2022 8/18/2025
Tank Composite Single Wall N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Flexible Double Wall Precision Test (Piping) Pass 8/9/2024



Tank Number 3

Capacity: 4000 Petroleum Use:
Product: Diesel Fuel CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 12/1/1997 Abandoned Material:
Current Age: 27 Abandoned Date:
Install Date: 8/5/1997 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 8/15/1997

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Flexible Non-Corrosive N/A N/A
Corrosion Prot - Tank Composite Non-Corrosive N/A N/A
Leak Detect - Piping Mechanical Pressurized Line Leak Detection 6/3/2025 6/3/2026
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 350 8/9/2024 8/9/2025
Overfill Prev Device Ball Float Vent Valve OPW 53 8/18/2022 8/18/2025
Piping Flexible Double Wall OmegaFlex DoubleTrac N/A N/A
Piping Single Wall STP/Tanktop Sump 5/27/2025 5/27/2028
Leak Detect - Piping Sump Sensor with positive shutdown 6/10/2025 6/10/2026
Spill Contain Device Single Wall Spill Bucket 8/18/2022 8/18/2025
Tank Composite Single Wall N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Flexible Double Wall Precision Test (Piping) Fail 8/9/2024
Piping Flexible Double Wall OmegaFlex DoubleTrac Precision Test (Piping) Pass 6/3/2025

Dispenser Information



Name\ID 1/2

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump
Leak Detect - Piping Sump Sensor with positive shutdown



Name\ID 3/4

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump
Leak Detect - Piping Sump Sensor with positive shutdown



Name\ID 5/6

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump
Leak Detect - Piping Sump Sensor with positive shutdown



Name\ID 7

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 5/27/2025 5/27/2028
Leak Detect - Piping Sump Sensor with positive shutdown 6/10/2025 6/10/2026

MFD Motorfuel Dispensing Forms

No Forms Found