Owner Summary
Click for Facility/Tank Ownership history
| Owner Number |
Owner Name |
Owner Status |
Purchase Date |
| U0036378 |
Bleyers Investments |
Current Owner |
7/2/2007 |
| U0036353 |
Bleyers Investments |
Former Owner |
12/6/2011 |
| U0002560 |
Casey's Retail Company |
Former Owner |
|
Notice of Violations (Current)
No Notice of Violations Found
IEMA Numbers Associated with the Facility
| IEMA Number |
Inspection Date |
Inspection Type |
Permit Number |
| N/A |
12/28/2011 |
Removal Log |
01228-2011REM |
LUST
Fund Eligibility and Deductibility Determinations
No Applications Found
Tank Number 1
| Capacity: |
10000 |
|
Petroleum Use: |
|
| Product: |
Gasoline |
|
CERCLA Substance: |
|
| Status: |
Removed |
|
CAS Code: |
|
| Regulated Status: |
Federal |
|
Removed Date: |
12/28/2011 |
|
OSFM
First Notify Date: |
10/29/1997 |
|
Abandoned Material: |
|
| Current Age: |
14 |
|
Abandoned Date: |
|
| Install Date: |
10/8/1997 |
|
Red Tag Issue Date: |
|
| Last Used Date: |
4/14/2008 |
|
Fee Due: |
$0.00 |
| Product Date: |
10/9/1997 |
|
|
|
Equipment Information
| Equipment Type |
Equipment |
Last Passing Date |
Test Expire Date |
|
Corrosion Prot - Piping
|
Sacrificial Anode Cathodic Protection |
1/5/2007 |
1/5/2010 |
|
Corrosion Prot - Piping
|
Fiberglass Non-Corrosive |
Not applicable |
Not applicable |
|
Corrosion Prot - Tank
|
Fiberglass Non-Corrosive |
Not applicable |
Not applicable |
|
Leak Detect - Piping
|
Electronic Pressurized Line Leak Detection |
10/13/2010 |
10/13/2011 |
|
Leak Detect - Tank
|
Automatic Tank Gauging Red Jacket RLM 9000 |
No passing test found |
No passing test found |
|
Overfill Prev Device
|
Ball Float Vent Valve OPW 53VM |
No passing test found |
No passing test found |
|
Piping
|
Fiberglass Single Wall Piping |
Not applicable |
Not applicable |
|
Spill Contain Device
|
Single Wall Spill Bucket |
No passing test found |
No passing test found |
|
Tank
|
Fiberglass Single Wall |
Not applicable |
Not applicable |
Additional Tests
No Tests Listed
Tank Number 2
| Capacity: |
10000 |
|
Petroleum Use: |
|
| Product: |
Gasoline |
|
CERCLA Substance: |
|
| Status: |
Removed |
|
CAS Code: |
|
| Regulated Status: |
Federal |
|
Removed Date: |
12/28/2011 |
|
OSFM
First Notify Date: |
10/29/1997 |
|
Abandoned Material: |
|
| Current Age: |
14 |
|
Abandoned Date: |
|
| Install Date: |
10/8/1997 |
|
Red Tag Issue Date: |
|
| Last Used Date: |
4/14/2008 |
|
Fee Due: |
$0.00 |
| Product Date: |
10/9/1997 |
|
|
|
Equipment Information
| Equipment Type |
Equipment |
Last Passing Date |
Test Expire Date |
|
Corrosion Prot - Piping
|
Sacrificial Anode Cathodic Protection |
1/5/2007 |
1/5/2010 |
|
Corrosion Prot - Piping
|
Fiberglass Non-Corrosive |
Not applicable |
Not applicable |
|
Corrosion Prot - Tank
|
Fiberglass Non-Corrosive |
Not applicable |
Not applicable |
|
Leak Detect - Piping
|
Electronic Pressurized Line Leak Detection |
10/13/2010 |
10/13/2011 |
|
Leak Detect - Tank
|
Automatic Tank Gauging Red Jacket RLM 9000 |
No passing test found |
No passing test found |
|
Overfill Prev Device
|
Ball Float Vent Valve OPW 53VM |
No passing test found |
No passing test found |
|
Piping
|
Fiberglass Single Wall Piping |
Not applicable |
Not applicable |
|
Spill Contain Device
|
Single Wall Spill Bucket |
No passing test found |
No passing test found |
|
Tank
|
Fiberglass Single Wall |
Not applicable |
Not applicable |
Additional Tests
No Tests Listed
Failed test = the latest test has failed.
Not applicable = a test does not apply to this equipment type or configuration.
No passing test found = a passing test is expected but was not found from the source data.
Dispenser Information
Failed test = the latest test has failed.
Not applicable = a test does not apply to this equipment type or configuration.
No passing test found = a passing test is expected but was not found from the source data.
MFD
Motorfuel Dispensing Forms
No Forms Found