Division of Petroleum & Chemical Safety

 

Facility Details

Facility Number: 7031384
Status: Active
Facility Name: Franklin Co Sheriff Dept
Address: 403 E Main Benton, IL 62812
County: Franklin
Property Parcel:
Facility Type: County
Owner Type: County
Green Tag Decal: AA03608
Green Tag Issue Date: 8/20/2025
Green Tag Expiration Date: 12/31/2027

Owner Details

Owner Name: Franklin Co Sheriff Dept
Owner Address: 403 E Main Benton, IL 62812
Owner Status: Current Owner / Operator
Purchase Date:
Type of Financial Responsibility: Surety Bond
Financial Responsibility Reporting Due Date: 7/25/2026

Motor Fuel Dispensing Permits

MFD Permit Type Issue Date Expiration Date
Fleet 8/20/2025 12/31/2027

Owner Summary

Click for Facility/Tank Ownership history
Owner Number Owner Name Owner Status Purchase Date
U0005415 Franklin Co Sheriff Dept Current Owner / Operator

Permits (Unexpired)

Click for permit history

No Active Permits Found

Notice of Violatlions (Current)

No Notice of Violations Found

IEMA Numbers Associated with the Facility

No IEMA Numbers Found

LUST Fund Eligibility and Deductibility Determinations

No Applications Found

Pay Tank Fees Online

Tank Information



Tank Number 1

Capacity: 1000 Petroleum Use:
Product: Gasoline - Regular CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 4/11/1992 Abandoned Material:
Current Age: 34 Abandoned Date:
Install Date: 12/1/1990 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date:

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Sacrificial Anode Flex Connector 1/19/2023 1/19/2026
Corrosion Prot - Piping Fiberglass Non-Corrosive N/A N/A
Corrosion Prot - Tank STIP3 Cathodic Protection with Dielectric Coating 1/19/2023 1/19/2026
Leak Detect - Piping European with No Test Req Suction N/A N/A
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 300 2/13/2025 2/13/2026
Overfill Prev Device Overfill Drop Tube Valve 1/13/2023 1/13/2026
Piping Fiberglass Single Wall Piping N/A N/A
Piping Not Installed STP/Tanktop Sump N/A N/A
Spill Contain Device Single Wall Spill Bucket 1/13/2023 1/13/2026
Tank STIP3 Single Wall N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date

Dispenser Information



Name\ID 1

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Not Installed UDC Sump N/A N/A

MFD Motorfuel Dispensing Forms

No Forms Found