Facility Details
Facility Number:
7028176
Status:
Closed
Facility Name:
Gas-N-Go 24-7
Address:
259 W. Main St.
Golconda, IL 62938
County:
Pope
Property Parcel:
Facility Type:
Attended Self-Service Station
Owner Type:
Private
Green Tag Decal:
O002405
Green Tag Issue Date:
9/11/2013
Green Tag Expiration Date:
12/31/2015
Owner Details
Owner Name:
Golconda Real Properties, LLC
Owner Address:
90 Old Golconda Road
Golconda, IL 62938
Owner Status:
Current Owner
Purchase Date:
3/14/2016
Type of Financial Responsibility:
Financial Responsibility Reporting Due Date:
Motor Fuel Dispensing Permits
MFD Permit Type
Issue Date
Expiration Date
Self Service
9/11/2013
12/31/2015
Owner Summary
Click for Facility/Tank Ownership history
Owner Number
Owner Name
Owner Status
Purchase Date
U0038385
Golconda Real Properties, LLC
Current Owner
3/14/2016
U0034044
Alchemist USA, LLC
Former Owner
2/21/2007
U0019992
Sisco Robert
Former Owner
1/28/1999
U0018007
Condy Convenience Mart Inc
Former Owner
12/31/1967
U0015667
Veach Oil Company
Former Owner
Permits (Unexpired)
Click for permit history
No Active Permits Found
Notice of Violations (Current)
No Notice of Violations Found
IEMA Numbers Associated with the Facility
IEMA Number
Inspection Date
Inspection Type
Permit Number
N/A
7/21/2016
Removal Log
00880-2016REM
LUST
Fund Eligibility and Deductibility Determinations
No Applications Found
Pay Tank Fees Online
Tank Information
Tank Number 1
Capacity:
5000
Petroleum Use:
Product:
Gasoline
CERCLA Substance:
Status:
Removed
CAS Code:
Regulated Status:
Federal
Removed Date:
7/21/2016
OSFM
First Notify Date:
10/14/1991
Abandoned Material:
Current Age:
35
Abandoned Date:
Install Date:
5/27/1981
Red Tag Issue Date:
Last Used Date:
9/8/2015
Fee Due:
$0.00
Product Date:
Equipment
Equipment Type
Equipment
Last Passing Date
Test Expire Date
Corrosion Prot - Piping
Sacrificial Anode Cathodic Protection
7/11/2011
7/11/2014
Corrosion Prot - Piping
Flexible Non-Corrosive
N/A
N/A
Corrosion Prot - Tank
Lining Materials Internal
7/21/2009
7/21/2014
Leak Detect - Piping
Electronic Pressurized Line Leak Detection
9/10/2013
9/10/2014
Leak Detect - Tank
Automatic Tank Gauging Incon TS 1001 with SCALD
Overfill Prev Device
Overfill Drop Tube Valve
Piping
Flexible Double Wall
N/A
N/A
Spill Contain Device
Single Wall Spill Bucket
Tank
Steel Single Wall
N/A
N/A
Additional Tests
Equipment Type
Equipment
Test Type
Test Result
Test Date
Tank Number 2
Capacity:
5000
Petroleum Use:
Product:
Diesel Fuel
CERCLA Substance:
Status:
Removed
CAS Code:
Regulated Status:
Federal
Removed Date:
7/21/2016
OSFM
First Notify Date:
10/14/1991
Abandoned Material:
Current Age:
35
Abandoned Date:
Install Date:
5/27/1981
Red Tag Issue Date:
Last Used Date:
9/8/2015
Fee Due:
$0.00
Product Date:
Equipment
Equipment Type
Equipment
Last Passing Date
Test Expire Date
Corrosion Prot - Piping
Sacrificial Anode Cathodic Protection
7/11/2011
7/11/2014
Corrosion Prot - Piping
Flexible Non-Corrosive
N/A
N/A
Corrosion Prot - Tank
Lining Materials Internal
7/21/2009
7/21/2014
Leak Detect - Piping
Electronic Pressurized Line Leak Detection
9/10/2013
9/10/2014
Leak Detect - Tank
Automatic Tank Gauging Incon TS 1001 with SCALD
Overfill Prev Device
Overfill Drop Tube Valve
Piping
Flexible Double Wall
N/A
N/A
Spill Contain Device
Single Wall Spill Bucket
Tank
Steel Single Wall
N/A
N/A
Additional Tests
Equipment Type
Equipment
Test Type
Test Result
Test Date
Dispenser Information
MFD
Motorfuel Dispensing Forms
No Forms Found