Owner Summary
Click for Facility/Tank Ownership history
| Owner Number |
Owner Name |
Owner Status |
Purchase Date |
| U0039424 |
Veer 2018, LLC |
Current Owner |
11/5/2018 |
| U0038567 |
I Khodal, LLC |
Former Owner |
6/10/2016 |
| U0029584 |
South Pointe Bank |
Former Owner |
7/6/2001 |
| U0030245 |
King Tut's LLC |
Former Owner |
6/30/2001 |
| U0027390 |
Toupals Country Corner Inc |
Former Owner |
6/16/2000 |
| U0022089 |
Duke & Long Distributing Co., Inc. |
Former Owner |
10/4/1993 |
| U0015667 |
Veach Oil Company |
Former Owner |
10/4/1993 |
| U0015106 |
Toupal Robert |
Former Owner |
12/31/1967 |
Permits (Unexpired)
Click for permit history
| Permit Number |
Type |
Status |
OSFM Receive Date |
Issue Date |
Expiration Date |
Documents |
| 00938-2026UPG |
Upgrade |
Approved / Issued |
8/7/2026 |
8/7/2026 |
2/9/2027 |
Documents |
Notice of Violations (Current)
NOV Number:
E0020261863
(Pending)
Issue Date:
7/21/2026
Expiration Date:
9/19/2026
View NOV Form
| Tanks |
Violations |
| 1 |
Tank precision test required. - Test requried due to water intrusion. Suspected leaking riser requires repair.
When an existing submersible pump is removed and replaced with another submersible pump, or when piping, flex connectors or other transitional components at the submersible pump are replaced, a submersible containment sump must be installed. A riser is considered a transitional component.
Tank must remain shut down until after repair and water removed. |
IEMA Numbers Associated with the Facility
| IEMA Number |
Inspection Date |
Inspection Type |
Permit Number |
| 20-0983 |
12/23/2020 |
Abandonment Log |
01661-2020ABN |
LUST
Fund Eligibility and Deductibility Determinations
| IEMA Number |
Status |
OSFM Received Date |
OSFM Response Date |
Deductible |
Letter |
| 20200983 |
Eligible |
1/14/2021
|
1/15/2021
|
$5,000
|
Letter
|
Tank Number 1
| Capacity: |
8000 |
|
Petroleum Use: |
|
| Product: |
Gasoline - Regular |
|
CERCLA Substance: |
|
| Status: |
Currently in use |
|
CAS Code: |
|
| Regulated Status: |
Federal |
|
Removed Date: |
|
|
OSFM
First Notify Date: |
8/2/1988 |
|
Abandoned Material: |
|
| Current Age: |
38 |
|
Abandoned Date: |
|
| Install Date: |
|
|
Red Tag Issue Date: |
|
| Last Used Date: |
|
|
Fee Due: |
$0.00 |
| Product Date: |
3/22/1988 |
|
|
|
Equipment Information
| Equipment Type |
Equipment |
Last Passing Date |
Test Expire Date |
|
Corrosion Prot - Piping
|
Sacrificial Anode Flex Connector |
10/5/2023 |
10/5/2026 |
|
Corrosion Prot - Piping
|
Fiberglass Non-Corrosive |
Not applicable |
Not applicable |
|
Corrosion Prot - Tank
|
STIP3 Cathodic Protection with Dielectric Coating |
10/5/2023 |
10/5/2026 |
|
Leak Detect - Piping
|
Mechanical Pressurized Line Leak Detection |
10/16/2025 |
10/16/2026 |
|
Leak Detect - Tank
|
Automatic Tank Gauging Incon TS 1001 with SCALD |
10/16/2025 |
10/16/2026 |
|
Overfill Prev Device
|
Overfill Drop Tube Valve |
10/4/2024 |
10/4/2027 |
|
Piping
|
Fiberglass Single Wall Piping |
Not applicable |
Not applicable |
|
Piping
|
Not Installed STP/Tanktop Sump |
Not applicable |
Not applicable |
|
Spill Contain Device
|
Single Wall Spill Bucket Insert |
10/4/2024 |
10/4/2027 |
|
Tank
|
STIP3 Single Wall |
Not applicable |
Not applicable |
Additional Tests
| Equipment Type |
Equipment |
Test Type |
Test Result |
Test Date |
|
Piping
|
Fiberglass Single Wall Piping
|
Precision Test (Piping)
|
Pass
|
10/16/2025
|
|
Tank
|
STIP3 Single Wall
|
Precision Test (Tank)
|
Pass
|
11/13/2024
|
Tank Number 2
| Capacity: |
8000 |
|
Petroleum Use: |
|
| Product: |
Gasoline - Premium |
|
CERCLA Substance: |
|
| Status: |
Abandoned in place |
|
CAS Code: |
|
| Regulated Status: |
Federal |
|
Removed Date: |
|
|
OSFM
First Notify Date: |
8/2/1988 |
|
Abandoned Material: |
Inert material mixed with portland cement |
| Current Age: |
38 |
|
Abandoned Date: |
12/23/2020 |
| Install Date: |
3/22/1988 |
|
Red Tag Issue Date: |
|
| Last Used Date: |
12/10/2019 |
|
Fee Due: |
$0.00 |
| Product Date: |
3/22/1988 |
|
|
|
Equipment Information
| Equipment Type |
Equipment |
Last Passing Date |
Test Expire Date |
|
Corrosion Prot - Piping
|
Sacrificial Anode Cathodic Protection |
9/19/2017 |
9/19/2020 |
|
Corrosion Prot - Piping
|
Isolation Boots Flex Connector |
Not applicable |
Not applicable |
|
Corrosion Prot - Piping
|
Fiberglass Non-Corrosive |
Not applicable |
Not applicable |
|
Corrosion Prot - Tank
|
STIP3 Cathodic Protection with Dielectric Coating |
9/19/2017 |
9/19/2020 |
|
Leak Detect - Piping
|
Mechanical Pressurized Line Leak Detection |
10/17/2019 |
10/17/2020 |
|
Leak Detect - Tank
|
Automatic Tank Gauging Incon TS 1001 with SCALD |
10/17/2019 |
10/17/2020 |
|
Overfill Prev Device
|
Overfill Drop Tube Valve |
10/23/2018 |
10/23/2021 |
|
Piping
|
Fiberglass Single Wall Piping |
Not applicable |
Not applicable |
|
Piping
|
Not Installed STP/Tanktop Sump |
Not applicable |
Not applicable |
|
Spill Contain Device
|
Single Wall Spill Bucket |
10/23/2018 |
10/23/2021 |
|
Tank
|
STIP3 Single Wall |
Not applicable |
Not applicable |
Additional Tests
| Equipment Type |
Equipment |
Test Type |
Test Result |
Test Date |
|
Piping
|
Fiberglass Single Wall Piping
|
Precision Test (Piping)
|
Pass
|
10/17/2019
|
|
Tank
|
STIP3 Single Wall
|
Precision Test (Tank)
|
Fail
|
12/10/2019
|
Tank Number 3
| Capacity: |
4000 |
|
Petroleum Use: |
None |
| Product: |
Gasoline - Non Ethanol |
|
CERCLA Substance: |
|
| Status: |
Currently in use |
|
CAS Code: |
|
| Regulated Status: |
Federal |
|
Removed Date: |
|
|
OSFM
First Notify Date: |
7/22/1991 |
|
Abandoned Material: |
|
| Current Age: |
35 |
|
Abandoned Date: |
|
| Install Date: |
6/13/1991 |
|
Red Tag Issue Date: |
|
| Last Used Date: |
|
|
Fee Due: |
$0.00 |
| Product Date: |
6/22/1991 |
|
|
|
Equipment Information
| Equipment Type |
Equipment |
Last Passing Date |
Test Expire Date |
|
Corrosion Prot - Piping
|
Sacrificial Anode Cathodic Protection |
7/15/2025 |
7/15/2028 |
|
Corrosion Prot - Tank
|
STIP3 Cathodic Protection with Dielectric Coating |
10/5/2023 |
10/5/2026 |
|
Leak Detect - Piping
|
European with No Test Req Suction |
Not applicable |
Not applicable |
|
Leak Detect - Tank
|
Automatic Tank Gauging Incon TS 1001 with SCALD |
10/16/2025 |
10/16/2026 |
|
Overfill Prev Device
|
Overfill Drop Tube Valve |
10/4/2024 |
10/4/2027 |
|
Piping
|
Fiberglass Single Wall Piping |
Not applicable |
Not applicable |
|
Piping
|
Not Installed STP/Tanktop Sump |
Not applicable |
Not applicable |
|
Spill Contain Device
|
Single Wall Spill Bucket |
10/4/2024 |
10/4/2027 |
|
Tank
|
STIP3 Single Wall |
Not applicable |
Not applicable |
Additional Tests
No Tests Listed
Tank Number 4
| Capacity: |
12000 |
|
Petroleum Use: |
|
| Product: |
Diesel Fuel |
|
CERCLA Substance: |
|
| Status: |
Does Not Exist |
|
CAS Code: |
|
| Regulated Status: |
Federal |
|
Removed Date: |
|
|
OSFM
First Notify Date: |
|
|
Abandoned Material: |
|
| Current Age: |
|
|
Abandoned Date: |
|
| Install Date: |
|
|
Red Tag Issue Date: |
|
| Last Used Date: |
|
|
Fee Due: |
|
| Product Date: |
|
|
|
|
Equipment Information
No Equipment Listed
Additional Tests
No Tests Listed
Failed test = the latest test has failed.
Not applicable = a test does not apply to this equipment type or configuration.
No passing test found = a passing test is expected but was not found from the source data.
Dispenser Information
Name\ID 1/2
| Status: |
Active |
|
| Equipment Type |
Equipment |
Last Passing Date |
Test Expire Date |
|
Dispenser
|
Not Installed UDC Sump |
Not applicable
|
Not applicable
|
Name\ID 3/4
| Status: |
Active |
|
| Equipment Type |
Equipment |
Last Passing Date |
Test Expire Date |
|
Dispenser
|
Not Installed UDC Sump |
Not applicable
|
Not applicable
|
Name\ID 5/6
| Status: |
Active |
|
| Equipment Type |
Equipment |
Last Passing Date |
Test Expire Date |
|
Dispenser
|
Not Installed UDC Sump |
Not applicable
|
Not applicable
|
Name\ID 7/8
| Status: |
Active |
|
| Equipment Type |
Equipment |
Last Passing Date |
Test Expire Date |
|
Dispenser
|
Not Installed UDC Sump |
Not applicable
|
Not applicable
|
Name\ID 9/10
| Status: |
Active |
|
| Equipment Type |
Equipment |
Last Passing Date |
Test Expire Date |
|
Dispenser
|
Not Installed UDC Sump |
Not applicable
|
Not applicable
|
Failed test = the latest test has failed.
Not applicable = a test does not apply to this equipment type or configuration.
No passing test found = a passing test is expected but was not found from the source data.
MFD
Motorfuel Dispensing Forms
No Forms Found