Division of Petroleum & Chemical Safety

 

Facility Details

Facility Number: 7021611
Status: Active
Facility Name: SPM Group, Ltd. d/b/a Albion Citgo
Address: 46 North 4th Street Main Street Albion, IL 62806
County: Edwards
Property Parcel: 03-2-056-02
Facility Type: Attended Self-Service Station
Owner Type: Private
Green Tag Decal: Y000060
Green Tag Issue Date: 5/8/2023
Green Tag Expiration Date: 12/31/2025

Owner Details

Owner Name: ARG KK10PCK001, LLC
Owner Address: 38 Washington Square Newport, RI 02840
Owner Status: Current Owner
Purchase Date: 12/11/2020
Type of Financial Responsibility: Commercial Insurance
Financial Responsibility Reporting Due Date: 9/3/2025

Motor Fuel Dispensing Permits

MFD Permit Type Issue Date Expiration Date
Self Service 5/8/2023 12/31/2025

Owner Summary

Click for Facility/Tank Ownership history
Owner Number Owner Name Owner Status Purchase Date
U0040111 ARG KK10PCK001, LLC Current Owner 12/11/2020
U0008547 Knapp Oil Company, Inc. Former Owner 1/1/1970

Permits (Unexpired)

Click for permit history

No Active Permits Found

Notice of Violatlions (Current)

No Notice of Violations Found

IEMA Numbers Associated with the Facility

IEMA Number Inspection Date Inspection Type Permit Number
14-0843 8/7/2014 Removal Log 00687-2014REM

LUST Fund Eligibility and Deductibility Determinations

IEMA Number Status OSFM Received Date OSFM Response Date Deductible Letter
14-0843 Eligible 8/25/2014 10/9/2014 $5,000
Pay Tank Fees Online

Tank Information



Tank Number 1

Capacity: 10000 Petroleum Use:
Product: E85 CERCLA Substance:
Status: Removed CAS Code:
Regulated Status: Federal Removed Date: 8/7/2014
OSFM First Notify Date: 5/6/1986 Abandoned Material:
Current Age: 28 Abandoned Date:
Install Date: 1/1/1983 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 1/1/1986

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Isolation Boots Flex Connector N/A N/A
Corrosion Prot - Piping Sacrificial Anode Flex Connector 12/10/2012 12/10/2015
Corrosion Prot - Piping Fiberglass Non-Corrosive N/A N/A
Corrosion Prot - Tank Lining Materials Internal 12/17/2013 12/17/2018
Corrosion Prot - Tank Fiberglass Non-Corrosive N/A N/A
Leak Detect - Piping Mechanical Pressurized Line Leak Detection 4/4/2013 4/4/2014
Leak Detect - Tank Ground Water Monitoring Electronic
Overfill Prev Device Overfill Drop Tube Valve
Piping Fiberglass Single Wall Piping N/A N/A
Spill Contain Device Single Wall Spill Bucket
Tank Steel Single Wall N/A N/A
Vent, Riser, Fill Piping Steel risers N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date



Tank Number 2

Capacity: 10000 Petroleum Use:
Product: Gasoline CERCLA Substance:
Status: Removed CAS Code:
Regulated Status: Federal Removed Date: 8/7/2014
OSFM First Notify Date: 5/6/1986 Abandoned Material:
Current Age: 31 Abandoned Date:
Install Date: 1/1/1983 Red Tag Issue Date:
Last Used Date: 12/17/2013 Fee Due: $0.00
Product Date: 1/1/1983

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Isolation Boots Flex Connector N/A N/A
Corrosion Prot - Piping Sacrificial Anode Flex Connector 12/10/2012 12/10/2015
Corrosion Prot - Piping Fiberglass Non-Corrosive N/A N/A
Corrosion Prot - Tank Lining Materials Internal 12/17/2013 12/17/2018
Corrosion Prot - Tank Fiberglass Non-Corrosive N/A N/A
Leak Detect - Piping Mechanical Pressurized Line Leak Detection 4/4/2013 4/4/2014
Leak Detect - Tank Ground Water Monitoring Electronic
Overfill Prev Device Overfill Drop Tube Valve
Piping Fiberglass Single Wall Piping N/A N/A
Spill Contain Device Single Wall Spill Bucket
Tank Steel Single Wall N/A N/A
Vent, Riser, Fill Piping Steel risers N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date



Tank Number 3

Capacity: 6000 Petroleum Use:
Product: Diesel Fuel CERCLA Substance:
Status: Removed CAS Code:
Regulated Status: Federal Removed Date: 8/7/2014
OSFM First Notify Date: 5/6/1986 Abandoned Material:
Current Age: 31 Abandoned Date:
Install Date: 1/1/1983 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 1/1/1983

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Isolation Boots Flex Connector N/A N/A
Corrosion Prot - Piping Sacrificial Anode Flex Connector 12/10/2012 12/10/2015
Corrosion Prot - Piping Fiberglass Non-Corrosive N/A N/A
Corrosion Prot - Tank Lining Materials Internal 12/18/2013 12/18/2018
Corrosion Prot - Tank Fiberglass Non-Corrosive N/A N/A
Leak Detect - Piping Mechanical Pressurized Line Leak Detection 4/4/2013 4/4/2014
Leak Detect - Tank Ground Water Monitoring Electronic
Overfill Prev Device Overfill Drop Tube Valve
Piping Fiberglass Single Wall Piping N/A N/A
Spill Contain Device Single Wall Spill Bucket
Tank Steel Single Wall N/A N/A
Vent, Riser, Fill Piping Steel risers N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date



Tank Number 4

Capacity: 8000 Petroleum Use:
Product: B-11 CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 10/29/1992 Abandoned Material:
Current Age: 35 Abandoned Date:
Install Date: 9/1/1989 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 9/1/1989

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Flexible Non-Corrosive N/A N/A
Corrosion Prot - Tank Sacrificial Anode Cathodic Protection 4/19/2023 4/19/2026
Leak Detect - Piping Electronic Pressurized Line Leak Detection 4/11/2025 4/11/2026
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 450 4/11/2025 4/11/2026
Overfill Prev Device Overfill Drop Tube Valve 4/11/2025 4/11/2028
Piping Flexible Double Wall A.P.T. Poly Tech P150SC N/A N/A
Piping Single Wall STP/Tanktop Sump 4/11/2025 4/11/2028
Leak Detect - Piping Sump Sensor with positive shutdown 4/11/2025 4/11/2026
Spill Contain Device Single Wall Spill Bucket 4/11/2025 4/11/2028
Tank STIP3 Single Wall N/A N/A
Vent, Riser, Fill Piping Steel risers N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Fiberglass Single Wall Piping Precision Test (Piping) Pass 4/19/2023
Piping Flexible Double Wall A.P.T. Poly Tech P150SC Precision Test (Piping) Pass 4/11/2025



Tank Number 5

Capacity: 2000 Petroleum Use:
Product: Kerosene CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 10/29/1992 Abandoned Material:
Current Age: 35 Abandoned Date:
Install Date: 9/1/1989 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 9/1/1989

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Fiberglass Non-Corrosive N/A N/A
Corrosion Prot - Tank Sacrificial Anode Cathodic Protection 4/19/2023 4/19/2026
Leak Detect - Piping European with No Test Req Suction N/A N/A
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 450 4/11/2025 4/11/2026
Overfill Prev Device Overfill Drop Tube Valve 4/11/2025 4/11/2028
Piping Fiberglass Single Wall Piping Ameron N/A N/A
Piping Not Installed STP/Tanktop Sump N/A N/A
Spill Contain Device Single Wall Spill Bucket 4/11/2025 4/11/2028
Tank STIP3 Single Wall N/A N/A
Vent, Riser, Fill Piping Steel risers N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date



Tank Number 6

Capacity: 12000 Petroleum Use:
Product: Gasoline - Regular CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 10/15/2014 Abandoned Material:
Current Age: 10 Abandoned Date:
Install Date: 8/20/2014 Red Tag Issue Date:
Last Used Date: Fee Due:
Product Date: 8/21/2014

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Flexible Non-Corrosive N/A N/A
Corrosion Prot - Tank Composite Non-Corrosive N/A N/A
Leak Detect - Piping Electronic Pressurized Line Leak Detection 4/11/2025 4/11/2026
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 450 4/11/2025 4/11/2026
Leak Detect - Tank Non-Discriminating Interstitial Monitoring Sensors 4/11/2025 4/11/2026
Overfill Prev Device Overfill Drop Tube Valve 4/11/2025 4/11/2028
Piping Flexible Double Wall A.P.T. Poly Tech P150SC N/A N/A
Piping Single Wall STP/Tanktop Sump 4/11/2025 4/11/2028
Leak Detect - Piping Sump Sensor with positive shutdown 4/11/2025 4/11/2026
Spill Contain Device Single Wall Spill Bucket 4/11/2025 4/11/2028
Tank Composite Double Wall Modern Welding Glasteel II N/A N/A
Vent, Riser, Fill Piping Steel risers N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Flexible Double Wall A.P.T. Poly Tech P150SC Precision Test (Piping) Pass 4/11/2025



Tank Number 7

Capacity: 6000 Petroleum Use:
Product: Gasoline - Premium CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 10/15/2014 Abandoned Material:
Current Age: 10 Abandoned Date:
Install Date: 8/20/2014 Red Tag Issue Date:
Last Used Date: Fee Due:
Product Date: 8/21/2014

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Flexible Non-Corrosive N/A N/A
Corrosion Prot - Tank Composite Non-Corrosive N/A N/A
Leak Detect - Piping Electronic Pressurized Line Leak Detection 4/11/2025 4/11/2026
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 450 4/11/2025 4/11/2026
Leak Detect - Tank Non-Discriminating Interstitial Monitoring Sensors 4/11/2025 4/11/2026
Overfill Prev Device Overfill Drop Tube Valve 4/11/2025 4/11/2028
Piping Flexible Double Wall A.P.T. Poly Tech P150SC N/A N/A
Piping Single Wall STP/Tanktop Sump 4/11/2025 4/11/2028
Leak Detect - Piping Sump Sensor with positive shutdown 4/11/2025 4/11/2026
Spill Contain Device Single Wall Spill Bucket 4/11/2025 4/11/2028
Tank Composite Double Wall Modern Welding Glasteel II N/A N/A
Vent, Riser, Fill Piping Steel risers N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Flexible Double Wall A.P.T. Poly Tech P150SC Precision Test (Piping) Pass 4/11/2025

Dispenser Information



Name\ID 1/2

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 4/11/2025 4/11/2028
Leak Detect - Piping Sump Sensor with positive shutdown 4/11/2025 4/11/2026



Name\ID 3/4

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 4/11/2025 4/11/2028
Leak Detect - Piping Sump Sensor with positive shutdown 4/11/2025 4/11/2026



Name\ID 5/6

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 4/11/2025 4/11/2028
Leak Detect - Piping Sump Sensor with positive shutdown 4/11/2025 4/11/2026



Name\ID 7/8

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 4/11/2025 4/11/2028
Leak Detect - Piping Sump Sensor with positive shutdown 4/11/2025 4/11/2026



Name\ID K-1

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Not Installed UDC Sump N/A N/A

MFD Motorfuel Dispensing Forms

No Forms Found