Owner Summary
Click for Facility/Tank Ownership history
| Owner Number |
Owner Name |
Owner Status |
Purchase Date |
| U0011913 |
Pilot Travel Centers, LLC |
Current Owner |
9/27/2011 |
| U0031179 |
Humrite Corporation |
Former Owner |
12/20/2002 |
| U0030816 |
Community National Bank |
Former Owner |
5/15/2002 |
| U0022089 |
Duke & Long Distributing Co., Inc. |
Former Owner |
10/14/1991 |
| U0012837 |
Rubens Marion Truck Plaza Inc |
Former Owner |
12/31/1967 |
Permits (Unexpired)
Click for permit history
| Permit Number |
Type |
Status |
OSFM Receive Date |
Issue Date |
Expiration Date |
Documents |
| 00785-2026UPG |
Upgrade |
Approved / Issued |
7/8/2026 |
7/8/2026 |
1/8/2027 |
Documents |
Notice of Violations (Current)
NOV Number:
E0020261618
(Pending)
Issue Date:
6/24/2026
Expiration Date:
8/23/2026
View NOV Form
| Tanks |
Violations |
| 19, 20, 21, 22, 23, 24 |
Line interstitial sensors have been raised and rendered inoperational. - Dispenser sumps #1/2, 5/6, 11/12, 13/14, 15/16, 17 Master, 21 Master, 22, Master, Diesel STP(T3) |
| Facility |
Miscellaneous - Each emergency stop shall be identified by a sign on all-weather materials stating "EMERGENCY STOP" in 2 inch red capital letters. 7 emergency stop buttons located by the dispenser islands are not identified. |
| 23, 24 |
Miscellaneous - Spill prevention equipment device requires repair. |
| 21 |
Monthly line interstitial sensor records not available. - Diesel 1 STP sump sensor removed from ATG programming. Repair/replace sensor. |
| 19, 20, 21, 22, 23, 24 |
Piping interstitial must be open in all sumps |
| 21, 22, 23, 24 |
Shear valve(s) not in proper working order. - Upon inspection the shear valve is tripped but did not close. Repair/replace. |
IEMA Numbers Associated with the Facility
| IEMA Number |
Inspection Date |
Inspection Type |
Permit Number |
| 11-1032 |
9/27/2011 |
Removal Log |
00917-2011REM |
| 11-1032 |
9/29/2011 |
Removal Log |
00917-2011REM |
| 11-1032 |
9/28/2011 |
Removal Log |
00917-2011REM |
| 91-0113 |
8/6/1992 |
Removal Log |
|
LUST
Fund Eligibility and Deductibility Determinations
| IEMA Number |
Status |
OSFM Received Date |
OSFM Response Date |
Deductible |
Letter |
| 11-1032 |
Eligible |
2/16/2012
|
4/9/2012
|
$5,000
|
|
Tank Number 7
| Capacity: |
10000 |
|
Petroleum Use: |
|
| Product: |
Gasoline |
|
CERCLA Substance: |
|
| Status: |
Removed |
|
CAS Code: |
|
| Regulated Status: |
Federal |
|
Removed Date: |
9/29/2011 |
|
OSFM
First Notify Date: |
12/19/1991 |
|
Abandoned Material: |
|
| Current Age: |
19 |
|
Abandoned Date: |
|
| Install Date: |
10/14/1991 |
|
Red Tag Issue Date: |
|
| Last Used Date: |
|
|
Fee Due: |
$0.00 |
| Product Date: |
10/14/1991 |
|
|
|
Equipment Information
| Equipment Type |
Equipment |
Last Passing Date |
Test Expire Date |
|
Corrosion Prot - Piping
|
Isolation Boots Flex Connector |
Not applicable |
Not applicable |
|
Corrosion Prot - Piping
|
Fiberglass Non-Corrosive |
Not applicable |
Not applicable |
|
Corrosion Prot - Tank
|
STIP3 Cathodic Protection with Dielectric Coating |
2/11/2009 |
2/11/2012 |
|
Leak Detect - Piping
|
Mechanical Pressurized Line Leak Detection |
3/11/2010 |
3/11/2011 |
|
Leak Detect - Tank
|
SIR and Prec Tightness Testing USTman Industries |
No passing test found |
No passing test found |
|
Overfill Prev Device
|
Ball Float Vent Valve OPW 53VM |
No passing test found |
No passing test found |
|
Piping
|
Fiberglass Single Wall Piping |
Not applicable |
Not applicable |
|
Spill Contain Device
|
Single Wall Spill Bucket |
No passing test found |
No passing test found |
|
Tank
|
STIP3 Single Wall |
Not applicable |
Not applicable |
Additional Tests
| Equipment Type |
Equipment |
Test Type |
Test Result |
Test Date |
|
Leak Detect - Tank
|
SIR and Prec Tightness Testing USTman Industries
|
Precision Test (Tank)
|
Pass
|
3/11/2010
|
Tank Number 8
| Capacity: |
10000 |
|
Petroleum Use: |
|
| Product: |
Gasoline |
|
CERCLA Substance: |
|
| Status: |
Removed |
|
CAS Code: |
|
| Regulated Status: |
Federal |
|
Removed Date: |
9/29/2011 |
|
OSFM
First Notify Date: |
12/19/1991 |
|
Abandoned Material: |
|
| Current Age: |
19 |
|
Abandoned Date: |
|
| Install Date: |
10/14/1991 |
|
Red Tag Issue Date: |
|
| Last Used Date: |
|
|
Fee Due: |
$0.00 |
| Product Date: |
10/14/1991 |
|
|
|
Equipment Information
| Equipment Type |
Equipment |
Last Passing Date |
Test Expire Date |
|
Corrosion Prot - Piping
|
Isolation Boots Flex Connector |
Not applicable |
Not applicable |
|
Corrosion Prot - Piping
|
Fiberglass Non-Corrosive |
Not applicable |
Not applicable |
|
Corrosion Prot - Tank
|
STIP3 Cathodic Protection with Dielectric Coating |
2/11/2009 |
2/11/2012 |
|
Leak Detect - Piping
|
Mechanical Pressurized Line Leak Detection |
3/11/2010 |
3/11/2011 |
|
Leak Detect - Tank
|
SIR and Prec Tightness Testing USTman Industries |
No passing test found |
No passing test found |
|
Overfill Prev Device
|
Ball Float Vent Valve OPW 53VM |
No passing test found |
No passing test found |
|
Piping
|
Fiberglass Single Wall Piping |
Not applicable |
Not applicable |
|
Spill Contain Device
|
Single Wall Spill Bucket |
No passing test found |
No passing test found |
|
Tank
|
STIP3 Single Wall |
Not applicable |
Not applicable |
Additional Tests
| Equipment Type |
Equipment |
Test Type |
Test Result |
Test Date |
|
Leak Detect - Tank
|
SIR and Prec Tightness Testing USTman Industries
|
Precision Test (Tank)
|
Pass
|
3/11/2010
|
Tank Number 9
| Capacity: |
10000 |
|
Petroleum Use: |
|
| Product: |
Gasoline |
|
CERCLA Substance: |
|
| Status: |
Removed |
|
CAS Code: |
|
| Regulated Status: |
Federal |
|
Removed Date: |
9/28/2011 |
|
OSFM
First Notify Date: |
12/19/1991 |
|
Abandoned Material: |
|
| Current Age: |
19 |
|
Abandoned Date: |
|
| Install Date: |
10/14/1991 |
|
Red Tag Issue Date: |
|
| Last Used Date: |
|
|
Fee Due: |
$0.00 |
| Product Date: |
10/14/1991 |
|
|
|
Equipment Information
| Equipment Type |
Equipment |
Last Passing Date |
Test Expire Date |
|
Corrosion Prot - Piping
|
Isolation Boots Flex Connector |
Not applicable |
Not applicable |
|
Corrosion Prot - Piping
|
Fiberglass Non-Corrosive |
Not applicable |
Not applicable |
|
Corrosion Prot - Tank
|
STIP3 Cathodic Protection with Dielectric Coating |
2/11/2009 |
2/11/2012 |
|
Leak Detect - Piping
|
Mechanical Pressurized Line Leak Detection |
3/11/2010 |
3/11/2011 |
|
Leak Detect - Tank
|
SIR and Prec Tightness Testing USTman Industries |
No passing test found |
No passing test found |
|
Overfill Prev Device
|
Ball Float Vent Valve OPW 53VM |
No passing test found |
No passing test found |
|
Piping
|
Fiberglass Single Wall Piping |
Not applicable |
Not applicable |
|
Spill Contain Device
|
Single Wall Spill Bucket |
No passing test found |
No passing test found |
|
Tank
|
STIP3 Single Wall |
Not applicable |
Not applicable |
Additional Tests
| Equipment Type |
Equipment |
Test Type |
Test Result |
Test Date |
|
Leak Detect - Tank
|
SIR and Prec Tightness Testing USTman Industries
|
Precision Test (Tank)
|
Pass
|
3/11/2010
|
Tank Number 10
| Capacity: |
12000 |
|
Petroleum Use: |
|
| Product: |
Diesel Fuel |
|
CERCLA Substance: |
|
| Status: |
Removed |
|
CAS Code: |
|
| Regulated Status: |
Federal |
|
Removed Date: |
9/27/2011 |
|
OSFM
First Notify Date: |
12/10/1992 |
|
Abandoned Material: |
|
| Current Age: |
19 |
|
Abandoned Date: |
|
| Install Date: |
10/14/1991 |
|
Red Tag Issue Date: |
|
| Last Used Date: |
|
|
Fee Due: |
$0.00 |
| Product Date: |
10/14/1991 |
|
|
|
Equipment Information
| Equipment Type |
Equipment |
Last Passing Date |
Test Expire Date |
|
Corrosion Prot - Piping
|
Isolation Boots Flex Connector |
Not applicable |
Not applicable |
|
Corrosion Prot - Piping
|
Fiberglass Non-Corrosive |
Not applicable |
Not applicable |
|
Corrosion Prot - Tank
|
STIP3 Cathodic Protection with Dielectric Coating |
2/11/2009 |
2/11/2012 |
|
Leak Detect - Piping
|
Mechanical Pressurized Line Leak Detection |
3/11/2010 |
3/11/2011 |
|
Leak Detect - Tank
|
Automatic Tank Gauging Veeder Root TLS 350 with CSLD |
No passing test found |
No passing test found |
|
Overfill Prev Device
|
Ball Float Vent Valve OPW 53VM |
No passing test found |
No passing test found |
|
Piping
|
Fiberglass Single Wall Piping |
Not applicable |
Not applicable |
|
Spill Contain Device
|
Single Wall Spill Bucket |
No passing test found |
No passing test found |
|
Tank
|
STIP3 Single Wall |
Not applicable |
Not applicable |
Additional Tests
No Tests Listed
Tank Number 11
| Capacity: |
12000 |
|
Petroleum Use: |
|
| Product: |
Diesel Fuel |
|
CERCLA Substance: |
|
| Status: |
Removed |
|
CAS Code: |
|
| Regulated Status: |
Federal |
|
Removed Date: |
9/27/2011 |
|
OSFM
First Notify Date: |
12/10/1992 |
|
Abandoned Material: |
|
| Current Age: |
19 |
|
Abandoned Date: |
|
| Install Date: |
10/14/1991 |
|
Red Tag Issue Date: |
|
| Last Used Date: |
|
|
Fee Due: |
$0.00 |
| Product Date: |
10/14/1991 |
|
|
|
Equipment Information
| Equipment Type |
Equipment |
Last Passing Date |
Test Expire Date |
|
Corrosion Prot - Piping
|
Isolation Boots Flex Connector |
Not applicable |
Not applicable |
|
Corrosion Prot - Piping
|
Fiberglass Non-Corrosive |
Not applicable |
Not applicable |
|
Corrosion Prot - Tank
|
STIP3 Cathodic Protection with Dielectric Coating |
2/11/2009 |
2/11/2012 |
|
Leak Detect - Piping
|
Mechanical Pressurized Line Leak Detection |
3/11/2010 |
3/11/2011 |
|
Leak Detect - Tank
|
Automatic Tank Gauging Veeder Root TLS 350 with CSLD |
No passing test found |
No passing test found |
|
Overfill Prev Device
|
Ball Float Vent Valve OPW 53VM |
No passing test found |
No passing test found |
|
Piping
|
Fiberglass Single Wall Piping |
Not applicable |
Not applicable |
|
Spill Contain Device
|
Single Wall Spill Bucket |
No passing test found |
No passing test found |
|
Tank
|
STIP3 Single Wall |
Not applicable |
Not applicable |
Additional Tests
No Tests Listed
Tank Number 12
| Capacity: |
12000 |
|
Petroleum Use: |
|
| Product: |
Diesel Fuel |
|
CERCLA Substance: |
|
| Status: |
Removed |
|
CAS Code: |
|
| Regulated Status: |
Federal |
|
Removed Date: |
9/27/2011 |
|
OSFM
First Notify Date: |
12/10/1992 |
|
Abandoned Material: |
|
| Current Age: |
19 |
|
Abandoned Date: |
|
| Install Date: |
10/14/1991 |
|
Red Tag Issue Date: |
|
| Last Used Date: |
|
|
Fee Due: |
$0.00 |
| Product Date: |
10/14/1991 |
|
|
|
Equipment Information
| Equipment Type |
Equipment |
Last Passing Date |
Test Expire Date |
|
Corrosion Prot - Piping
|
Isolation Boots Flex Connector |
Not applicable |
Not applicable |
|
Corrosion Prot - Piping
|
Fiberglass Non-Corrosive |
Not applicable |
Not applicable |
|
Corrosion Prot - Tank
|
STIP3 Cathodic Protection with Dielectric Coating |
2/11/2009 |
2/11/2012 |
|
Leak Detect - Piping
|
Mechanical Pressurized Line Leak Detection |
3/11/2010 |
3/11/2011 |
|
Leak Detect - Tank
|
Automatic Tank Gauging Veeder Root TLS 350 with CSLD |
No passing test found |
No passing test found |
|
Overfill Prev Device
|
Ball Float Vent Valve OPW 53VM |
No passing test found |
No passing test found |
|
Piping
|
Fiberglass Single Wall Piping |
Not applicable |
Not applicable |
|
Spill Contain Device
|
Single Wall Spill Bucket |
No passing test found |
No passing test found |
|
Tank
|
STIP3 Single Wall |
Not applicable |
Not applicable |
Additional Tests
No Tests Listed
Tank Number 13
| Capacity: |
8000 |
|
Petroleum Use: |
|
| Product: |
Diesel Fuel |
|
CERCLA Substance: |
|
| Status: |
Removed |
|
CAS Code: |
|
| Regulated Status: |
Federal |
|
Removed Date: |
8/6/1992 |
|
OSFM
First Notify Date: |
4/11/1986 |
|
Abandoned Material: |
|
| Current Age: |
27 |
|
Abandoned Date: |
|
| Install Date: |
|
|
Red Tag Issue Date: |
|
| Last Used Date: |
10/1/1991 |
|
Fee Due: |
$0.00 |
| Product Date: |
|
|
|
|
Equipment Information
No Equipment Listed
Additional Tests
No Tests Listed
Tank Number 14
| Capacity: |
6000 |
|
Petroleum Use: |
|
| Product: |
Gasoline |
|
CERCLA Substance: |
|
| Status: |
Removed |
|
CAS Code: |
|
| Regulated Status: |
Federal |
|
Removed Date: |
8/6/1992 |
|
OSFM
First Notify Date: |
4/11/1986 |
|
Abandoned Material: |
|
| Current Age: |
27 |
|
Abandoned Date: |
|
| Install Date: |
|
|
Red Tag Issue Date: |
|
| Last Used Date: |
10/1/1991 |
|
Fee Due: |
$0.00 |
| Product Date: |
|
|
|
|
Equipment Information
No Equipment Listed
Additional Tests
No Tests Listed
Tank Number 15
| Capacity: |
6000 |
|
Petroleum Use: |
|
| Product: |
Gasoline |
|
CERCLA Substance: |
|
| Status: |
Removed |
|
CAS Code: |
|
| Regulated Status: |
Federal |
|
Removed Date: |
8/6/1992 |
|
OSFM
First Notify Date: |
4/11/1986 |
|
Abandoned Material: |
|
| Current Age: |
27 |
|
Abandoned Date: |
|
| Install Date: |
|
|
Red Tag Issue Date: |
|
| Last Used Date: |
10/1/1991 |
|
Fee Due: |
$0.00 |
| Product Date: |
|
|
|
|
Equipment Information
No Equipment Listed
Additional Tests
No Tests Listed
Tank Number 16
| Capacity: |
8000 |
|
Petroleum Use: |
|
| Product: |
Diesel Fuel |
|
CERCLA Substance: |
|
| Status: |
Removed |
|
CAS Code: |
|
| Regulated Status: |
Federal |
|
Removed Date: |
8/6/1992 |
|
OSFM
First Notify Date: |
4/11/1986 |
|
Abandoned Material: |
|
| Current Age: |
27 |
|
Abandoned Date: |
|
| Install Date: |
|
|
Red Tag Issue Date: |
|
| Last Used Date: |
10/1/1991 |
|
Fee Due: |
$0.00 |
| Product Date: |
|
|
|
|
Equipment Information
No Equipment Listed
Additional Tests
No Tests Listed
Tank Number 17
| Capacity: |
8000 |
|
Petroleum Use: |
|
| Product: |
Diesel Fuel |
|
CERCLA Substance: |
|
| Status: |
Removed |
|
CAS Code: |
|
| Regulated Status: |
Federal |
|
Removed Date: |
8/6/1992 |
|
OSFM
First Notify Date: |
4/11/1986 |
|
Abandoned Material: |
|
| Current Age: |
27 |
|
Abandoned Date: |
|
| Install Date: |
|
|
Red Tag Issue Date: |
|
| Last Used Date: |
10/1/1991 |
|
Fee Due: |
$0.00 |
| Product Date: |
|
|
|
|
Equipment Information
No Equipment Listed
Additional Tests
No Tests Listed
Tank Number 18
| Capacity: |
8000 |
|
Petroleum Use: |
|
| Product: |
Diesel Fuel |
|
CERCLA Substance: |
|
| Status: |
Removed |
|
CAS Code: |
|
| Regulated Status: |
Federal |
|
Removed Date: |
8/6/1992 |
|
OSFM
First Notify Date: |
4/11/1986 |
|
Abandoned Material: |
|
| Current Age: |
27 |
|
Abandoned Date: |
|
| Install Date: |
|
|
Red Tag Issue Date: |
|
| Last Used Date: |
10/1/1991 |
|
Fee Due: |
$0.00 |
| Product Date: |
|
|
|
|
Equipment Information
No Equipment Listed
Additional Tests
No Tests Listed
Tank Number 19
| Capacity: |
16000 |
|
Petroleum Use: |
|
| Product: |
E15 |
|
CERCLA Substance: |
|
| Status: |
Currently in use |
|
CAS Code: |
|
| Regulated Status: |
Federal |
|
Removed Date: |
|
|
OSFM
First Notify Date: |
1/2/2025 |
|
Abandoned Material: |
|
| Current Age: |
14 |
|
Abandoned Date: |
|
| Install Date: |
10/11/2011 |
|
Red Tag Issue Date: |
|
| Last Used Date: |
|
|
Fee Due: |
$0.00 |
| Product Date: |
11/21/2011 |
|
|
|
Equipment Information
| Equipment Type |
Equipment |
Last Passing Date |
Test Expire Date |
|
Corrosion Prot - Piping
|
Fiberglass Non-Corrosive |
Not applicable |
Not applicable |
|
Corrosion Prot - Tank
|
Fiberglass Non-Corrosive |
Not applicable |
Not applicable |
|
Leak Detect - Piping
|
Mechanical Pressurized Line Leak Detection |
10/7/2025 |
10/7/2026 |
|
Leak Detect - Tank
|
Non-Discriminating Interstitial Monitoring Sensors With Monitor |
10/7/2025 |
10/7/2026 |
|
Overfill Prev Device
|
Overfill Drop Tube Valve |
11/3/2023 |
11/3/2026 |
|
Piping
|
Fiberglass Double Wall Ameron Dualoy 3000/LCX |
Not applicable |
Not applicable |
|
Piping
|
Single Wall STP/Tanktop Sump |
4/4/2025 |
4/4/2028 |
Leak Detect - Piping
|
Sump Sensor with positive shutdown |
4/4/2025 |
4/4/2028 |
|
Spill Contain Device
|
Double Wall Spill Bucket |
4/22/2025 |
4/22/2028 |
|
Tank
|
Fiberglass Double Wall XERXES |
Not applicable |
Not applicable |
Additional Tests
| Equipment Type |
Equipment |
Test Type |
Test Result |
Test Date |
|
Piping
|
Fiberglass Double Wall Ameron Dualoy 3000/LCX
|
Precision Test (Piping)
|
Pass
|
10/7/2025
|
|
Tank
|
Fiberglass Double Wall XERXES
|
Precision Test (Tank)
|
Pass
|
10/8/2024
|
Tank Number 20
| Capacity: |
9000 |
|
Petroleum Use: |
|
| Product: |
Gasoline - Premium |
|
CERCLA Substance: |
|
| Status: |
Currently in use |
|
CAS Code: |
|
| Regulated Status: |
Federal |
|
Removed Date: |
|
|
OSFM
First Notify Date: |
12/12/2011 |
|
Abandoned Material: |
|
| Current Age: |
14 |
|
Abandoned Date: |
|
| Install Date: |
10/11/2011 |
|
Red Tag Issue Date: |
|
| Last Used Date: |
|
|
Fee Due: |
$0.00 |
| Product Date: |
11/21/2011 |
|
|
|
Equipment Information
| Equipment Type |
Equipment |
Last Passing Date |
Test Expire Date |
|
Corrosion Prot - Piping
|
Fiberglass Non-Corrosive |
Not applicable |
Not applicable |
|
Corrosion Prot - Tank
|
Fiberglass Non-Corrosive |
Not applicable |
Not applicable |
|
Leak Detect - Piping
|
Mechanical Pressurized Line Leak Detection |
10/7/2025 |
10/7/2026 |
|
Leak Detect - Tank
|
Non-Discriminating Interstitial Monitoring Sensors With Monitor |
10/7/2025 |
10/7/2026 |
|
Overfill Prev Device
|
Overfill Drop Tube Valve |
10/13/2023 |
10/13/2026 |
|
Piping
|
Fiberglass Double Wall Ameron Dualoy 3000/LCX |
Not applicable |
Not applicable |
|
Piping
|
Single Wall STP/Tanktop Sump |
4/4/2025 |
4/4/2028 |
Leak Detect - Piping
|
Sump Sensor with positive shutdown |
4/4/2025 |
4/4/2028 |
|
Spill Contain Device
|
Double Wall Spill Bucket |
4/22/2025 |
4/22/2028 |
|
Tank
|
Fiberglass Double Wall XERXES |
Not applicable |
Not applicable |
Additional Tests
| Equipment Type |
Equipment |
Test Type |
Test Result |
Test Date |
|
Piping
|
Fiberglass Double Wall Ameron Dualoy 3000/LCX
|
Precision Test (Piping)
|
Pass
|
10/7/2025
|
Tank Number 21
| Capacity: |
20000 |
|
Petroleum Use: |
|
| Product: |
Diesel Fuel |
|
CERCLA Substance: |
|
| Status: |
Currently in use |
|
CAS Code: |
|
| Regulated Status: |
Federal |
|
Removed Date: |
|
|
OSFM
First Notify Date: |
12/12/2011 |
|
Abandoned Material: |
|
| Current Age: |
14 |
|
Abandoned Date: |
|
| Install Date: |
10/11/2011 |
|
Red Tag Issue Date: |
|
| Last Used Date: |
|
|
Fee Due: |
$0.00 |
| Product Date: |
11/21/2011 |
|
|
|
Equipment Information
| Equipment Type |
Equipment |
Last Passing Date |
Test Expire Date |
|
Corrosion Prot - Piping
|
Fiberglass Non-Corrosive |
Not applicable |
Not applicable |
|
Corrosion Prot - Tank
|
Fiberglass Non-Corrosive |
Not applicable |
Not applicable |
|
Leak Detect - Piping
|
Mechanical Pressurized Line Leak Detection |
10/14/2025 |
10/14/2026 |
|
Leak Detect - Tank
|
Non-Discriminating Interstitial Monitoring Sensors With Monitor |
10/7/2025 |
10/7/2026 |
|
Overfill Prev Device
|
Overfill Drop Tube Valve |
10/13/2023 |
10/13/2026 |
|
Piping
|
Fiberglass Double Wall Ameron Dualoy 3000/LCX |
Not applicable |
Not applicable |
|
Piping
|
Single Wall STP/Tanktop Sump |
7/22/2025 |
7/22/2028 |
Leak Detect - Piping
|
Sump Sensor with positive shutdown |
7/22/2025 |
7/22/2028 |
|
Piping
|
Single Wall Transition Sump |
4/4/2025 |
4/4/2028 |
Leak Detect - Piping
|
Sump Sensor with positive shutdown |
4/4/2025 |
4/4/2028 |
|
Piping
|
Single Wall Transition Sump |
4/4/2025 |
4/4/2028 |
Leak Detect - Piping
|
Sump Sensor with positive shutdown |
4/4/2025 |
4/4/2028 |
|
Spill Contain Device
|
Double Wall Spill Bucket |
9/24/2025 |
9/24/2028 |
|
Tank
|
Fiberglass Double Wall XERXES |
Not applicable |
Not applicable |
Additional Tests
| Equipment Type |
Equipment |
Test Type |
Test Result |
Test Date |
|
Piping
|
Fiberglass Double Wall Ameron Dualoy 3000/LCX
|
Precision Test (Piping)
|
Pass
|
10/8/2024
|
|
Piping
|
Fiberglass Double Wall Ameron Dualoy 3000/LCX
|
Precision Test (Piping)
|
Pass
|
10/7/2025
|
Tank Number 22
| Capacity: |
20000 |
|
Petroleum Use: |
|
| Product: |
Diesel Fuel |
|
CERCLA Substance: |
|
| Status: |
Currently in use |
|
CAS Code: |
|
| Regulated Status: |
Federal |
|
Removed Date: |
|
|
OSFM
First Notify Date: |
12/12/2011 |
|
Abandoned Material: |
|
| Current Age: |
14 |
|
Abandoned Date: |
|
| Install Date: |
10/11/2011 |
|
Red Tag Issue Date: |
|
| Last Used Date: |
|
|
Fee Due: |
$0.00 |
| Product Date: |
11/21/2011 |
|
|
|
Equipment Information
| Equipment Type |
Equipment |
Last Passing Date |
Test Expire Date |
|
Corrosion Prot - Piping
|
Fiberglass Non-Corrosive |
Not applicable |
Not applicable |
|
Corrosion Prot - Tank
|
Fiberglass Non-Corrosive |
Not applicable |
Not applicable |
|
Leak Detect - Piping
|
Siphon Bar |
Not applicable |
Not applicable |
|
Leak Detect - Tank
|
Non-Discriminating Interstitial Monitoring Sensors With Monitor |
10/7/2025 |
10/7/2026 |
|
Overfill Prev Device
|
Overfill Drop Tube Valve |
10/13/2023 |
10/13/2026 |
|
Piping
|
Fiberglass Double Wall Ameron Dualoy 3000/LCX |
Not applicable |
Not applicable |
|
Piping
|
Single Wall STP/Tanktop Sump |
Not applicable |
Not applicable |
Leak Detect - Piping
|
Piping Sump Sensors Not Regulated |
4/4/2025 |
4/4/2028 |
|
Spill Contain Device
|
Double Wall Spill Bucket |
4/22/2025 |
4/22/2028 |
|
Tank
|
Fiberglass Double Wall XERXES |
Not applicable |
Not applicable |
Additional Tests
| Equipment Type |
Equipment |
Test Type |
Test Result |
Test Date |
|
Leak Detect - Piping
|
Siphon Bar
|
Functional
|
Pass
|
10/7/2025
|
|
Piping
|
Fiberglass Double Wall Ameron Dualoy 3000/LCX
|
Precision Test (Piping)
|
Pass
|
10/7/2025
|
Tank Number 23
| Capacity: |
20000 |
|
Petroleum Use: |
|
| Product: |
Diesel Fuel |
|
CERCLA Substance: |
|
| Status: |
Currently in use |
|
CAS Code: |
|
| Regulated Status: |
Federal |
|
Removed Date: |
|
|
OSFM
First Notify Date: |
12/12/2011 |
|
Abandoned Material: |
|
| Current Age: |
14 |
|
Abandoned Date: |
|
| Install Date: |
10/11/2011 |
|
Red Tag Issue Date: |
|
| Last Used Date: |
|
|
Fee Due: |
$0.00 |
| Product Date: |
11/21/2011 |
|
|
|
Equipment Information
| Equipment Type |
Equipment |
Last Passing Date |
Test Expire Date |
|
Corrosion Prot - Piping
|
Fiberglass Non-Corrosive |
Not applicable |
Not applicable |
|
Corrosion Prot - Tank
|
Fiberglass Non-Corrosive |
Not applicable |
Not applicable |
|
Leak Detect - Piping
|
Mechanical Pressurized Line Leak Detection |
10/14/2025 |
10/14/2026 |
|
Leak Detect - Tank
|
Non-Discriminating Interstitial Monitoring Sensors With Monitor |
10/7/2025 |
10/7/2026 |
|
Overfill Prev Device
|
Overfill Drop Tube Valve |
10/13/2023 |
10/13/2026 |
|
Piping
|
Fiberglass Double Wall Ameron Dualoy 3000/LCX |
Not applicable |
Not applicable |
|
Piping
|
Single Wall STP/Tanktop Sump |
4/4/2025 |
4/4/2028 |
Leak Detect - Piping
|
Sump Sensor with positive shutdown |
4/4/2025 |
4/4/2028 |
|
Piping
|
Single Wall Transition Sump |
4/4/2025 |
4/4/2028 |
Leak Detect - Piping
|
Sump Sensor with positive shutdown |
4/4/2025 |
4/4/2028 |
|
Piping
|
Single Wall Transition Sump |
4/4/2025 |
4/4/2028 |
Leak Detect - Piping
|
Sump Sensor with positive shutdown |
4/4/2025 |
4/4/2028 |
|
Spill Contain Device
|
Double Wall Spill Bucket |
9/29/2025 |
9/29/2028 |
|
Tank
|
Fiberglass Double Wall XERXES |
Not applicable |
Not applicable |
Additional Tests
| Equipment Type |
Equipment |
Test Type |
Test Result |
Test Date |
|
Piping
|
Fiberglass Double Wall Ameron Dualoy 3000/LCX
|
Precision Test (Piping)
|
Pass
|
10/7/2025
|
Tank Number 24
| Capacity: |
15000 |
|
Petroleum Use: |
|
| Product: |
B-99 |
|
CERCLA Substance: |
|
| Status: |
Currently in use |
|
CAS Code: |
|
| Regulated Status: |
Federal |
|
Removed Date: |
|
|
OSFM
First Notify Date: |
12/12/2011 |
|
Abandoned Material: |
|
| Current Age: |
14 |
|
Abandoned Date: |
|
| Install Date: |
10/11/2011 |
|
Red Tag Issue Date: |
|
| Last Used Date: |
|
|
Fee Due: |
$0.00 |
| Product Date: |
11/21/2011 |
|
|
|
Equipment Information
| Equipment Type |
Equipment |
Last Passing Date |
Test Expire Date |
|
Corrosion Prot - Piping
|
Fiberglass Non-Corrosive |
Not applicable |
Not applicable |
|
Corrosion Prot - Tank
|
Fiberglass Non-Corrosive |
Not applicable |
Not applicable |
|
Leak Detect - Piping
|
European with No Test Req Suction |
Not applicable |
Not applicable |
|
Leak Detect - Tank
|
Non-Discriminating Interstitial Monitoring Sensors With Monitor |
10/7/2025 |
10/7/2026 |
|
Overfill Prev Device
|
Overfill Drop Tube Valve |
10/13/2023 |
10/13/2026 |
|
Piping
|
Blending Sump |
4/4/2025 |
4/4/2028 |
Leak Detect - Piping
|
Sump Sensor with positive shutdown |
4/4/2025 |
4/4/2028 |
|
Piping
|
Fiberglass Double Wall Ameron Dualoy 3000/LCX |
Not applicable |
Not applicable |
|
Piping
|
Single Wall STP/Tanktop Sump |
Not applicable |
Not applicable |
Leak Detect - Piping
|
Piping Sump Sensors Not Regulated |
4/4/2025 |
4/4/2028 |
|
Spill Contain Device
|
Double Wall Spill Bucket |
4/22/2025 |
4/22/2028 |
|
Tank
|
Fiberglass Double Wall XERXES |
Not applicable |
Not applicable |
Additional Tests
| Equipment Type |
Equipment |
Test Type |
Test Result |
Test Date |
|
Piping
|
Fiberglass Double Wall Ameron Dualoy 3000/LCX
|
Precision Test (Piping)
|
Pass
|
7/24/2025
|
Tank Number 25
| Capacity: |
8000 |
|
Petroleum Use: |
|
| Product: |
Diesel Exhaust Fluid (Non-Regulated) |
|
CERCLA Substance: |
|
| Status: |
Unknown |
|
CAS Code: |
|
| Regulated Status: |
Non-Regulated |
|
Removed Date: |
|
|
OSFM
First Notify Date: |
12/12/2011 |
|
Abandoned Material: |
|
| Current Age: |
14 |
|
Abandoned Date: |
|
| Install Date: |
10/11/2011 |
|
Red Tag Issue Date: |
|
| Last Used Date: |
|
|
Fee Due: |
|
| Product Date: |
11/21/2011 |
|
|
|
Equipment Information
No Equipment Listed
Additional Tests
No Tests Listed
Failed test = the latest test has failed.
Not applicable = a test does not apply to this equipment type or configuration.
No passing test found = a passing test is expected but was not found from the source data.
MFD