Information
JB Pritzker, Governor
James A. Rivera, State Fire Marshal
Division of Petroleum & Chemical Safety
State of Illinois
Employment Opportunities
Ready Illinois
Find us on Facebook
UST
Search
Contractor Search
Permit Search
Disclaimer & Rules/Statutes
Disclaimer
Rules
Statutes
Statistics & Reports
Statistics
Red Tag Tanks
Blended Fuel Tanks
Federal Energy Act Reports
Help
Division of Petroleum & Chemical Safety
Facility Details
Facility Number:
7011358
Status:
Closed
Facility Name:
Kieffer Brothers Construction Company
Address:
126 Division Street
Mount Carmel, IL 62863
County:
Wabash
Property Parcel:
11-29-113-009
Facility Type:
Commercial / Retail
Owner Type:
Private
Green Tag Decal:
S002028
Green Tag Issue Date:
7/26/2017
Green Tag Expiration Date:
12/31/2019
Owner Details
Owner Name:
Rick Anderson
Owner Address:
15889 Friendsville Ave.
Mount Carmel, IL 62863
Owner Status:
Current Owner
Purchase Date:
8/25/2019
Type of Financial Responsibility:
Financial Responsibility Reporting Due Date:
Motor Fuel Dispensing Permits
MFD Permit Type
Issue Date
Expiration Date
Fleet
7/13/2017
12/31/2019
Owner Summary
Click for Facility/Tank Ownership history
Owner Number
Owner Name
Owner Status
Purchase Date
U0039595
Anderson, Rick
Current Owner
8/25/2019
U0000619
L.E. Anderson Brothers Oil Company, Inc.
Former Owner
Permits (Unexpired)
Click for permit history
Permit Number
Type
Status
OSFM Receive Date
Issue Date
Expiration Date
Documents
00374-2025REM
Removal
Approved / Issued
3/28/2025
3/31/2025
9/30/2025
Documents
Notice of Violations (Current)
No Notice of Violations Found
IEMA Numbers Associated with the Facility
IEMA Number
Inspection Date
Inspection Type
Permit Number
2025-0193
4/22/2025
Removal Log
00374-2025REM
LUST
Fund Eligibility and Deductibility Determinations
No Applications Found
Pay Tank Fees Online
Tank Information
Tank Number 1
Capacity:
1000
Petroleum Use:
None
Product:
Diesel Fuel
CERCLA Substance:
Status:
Removed
CAS Code:
Regulated Status:
Federal
Removed Date:
4/22/2025
OSFM
First Notify Date:
5/19/1986
Abandoned Material:
Current Age:
40
Abandoned Date:
Install Date:
6/5/1984
Red Tag Issue Date:
Last Used Date:
12/28/2019
Fee Due:
$0.00
Product Date:
6/5/1984
Equipment
Equipment Type
Equipment
Last Passing Date
Test Expire Date
Corrosion Prot - Piping
Impressed Current Cathodic Protection
7/14/2017
7/14/2018
Corrosion Prot - Tank
Impressed Current Cathodic Protection
7/14/2017
7/14/2018
Leak Detect - Piping
European with No Test Req Suction
N/A
N/A
Leak Detect - Tank
SIR and Prec Tightness Testing
Overfill Prev Device
Overfill Drop Tube Valve
Piping
Galvanized Steel Single Wall Piping
N/A
N/A
Spill Contain Device
Single Wall Spill Bucket
Tank
Steel Single Wall
N/A
N/A
Vent, Riser, Fill Piping
Steel risers
N/A
N/A
Additional Tests
Equipment Type
Equipment
Test Type
Test Result
Test Date
Leak Detect - Tank
SIR and Prec Tightness Testing
Precision Test (Tank)
Pass
7/13/2017
Tank Number 2
Capacity:
1000
Petroleum Use:
None
Product:
Diesel Fuel
CERCLA Substance:
Status:
Removed
CAS Code:
Regulated Status:
Federal
Removed Date:
4/22/2025
OSFM
First Notify Date:
5/19/1986
Abandoned Material:
Current Age:
40
Abandoned Date:
Install Date:
6/5/1984
Red Tag Issue Date:
Last Used Date:
12/28/2019
Fee Due:
$0.00
Product Date:
6/5/1984
Equipment
Equipment Type
Equipment
Last Passing Date
Test Expire Date
Corrosion Prot - Piping
Impressed Current Cathodic Protection
7/14/2017
7/14/2018
Corrosion Prot - Tank
Impressed Current Cathodic Protection
7/14/2017
7/14/2018
Leak Detect - Piping
European with No Test Req Suction
N/A
N/A
Leak Detect - Tank
SIR and Prec Tightness Testing
Overfill Prev Device
Overfill Drop Tube Valve
Piping
Galvanized Steel Single Wall Piping
N/A
N/A
Spill Contain Device
Single Wall Spill Bucket
Tank
Steel Single Wall
N/A
N/A
Vent, Riser, Fill Piping
Steel risers
N/A
N/A
Additional Tests
Equipment Type
Equipment
Test Type
Test Result
Test Date
Leak Detect - Tank
SIR and Prec Tightness Testing
Precision Test (Tank)
Pass
7/13/2017
Tank Number 3
Capacity:
1000
Petroleum Use:
Product:
Gasoline
CERCLA Substance:
Status:
Removed
CAS Code:
Regulated Status:
Federal
Removed Date:
4/22/2025
OSFM
First Notify Date:
5/19/1986
Abandoned Material:
Current Age:
40
Abandoned Date:
Install Date:
6/5/1984
Red Tag Issue Date:
Last Used Date:
12/28/2019
Fee Due:
$0.00
Product Date:
6/5/1984
Equipment
Equipment Type
Equipment
Last Passing Date
Test Expire Date
Corrosion Prot - Piping
Impressed Current Cathodic Protection
7/14/2017
7/14/2018
Corrosion Prot - Tank
Impressed Current Cathodic Protection
7/14/2017
7/14/2018
Leak Detect - Piping
European with No Test Req Suction
N/A
N/A
Leak Detect - Tank
SIR and Prec Tightness Testing
Overfill Prev Device
Overfill Drop Tube Valve
Piping
Galvanized Steel Single Wall Piping
N/A
N/A
Spill Contain Device
Single Wall Spill Bucket
Tank
Steel Single Wall
N/A
N/A
Vent, Riser, Fill Piping
Steel risers
N/A
N/A
Additional Tests
Equipment Type
Equipment
Test Type
Test Result
Test Date
Leak Detect - Tank
SIR and Prec Tightness Testing
Precision Test (Tank)
Pass
7/13/2017
Dispenser Information
MFD
Motorfuel Dispensing Forms
No Forms Found