Notice of Violations (Current)
No Notice of Violations Found
IEMA Numbers Associated with the Facility
| IEMA Number |
Inspection Date |
Inspection Type |
Permit Number |
| N/A |
1/15/2020 |
Abandonment Log |
02314-2019ABN |
LUST
Fund Eligibility and Deductibility Determinations
No Applications Found
Tank Number 1
| Capacity: |
12000 |
|
Petroleum Use: |
None |
| Product: |
Diesel Fuel |
|
CERCLA Substance: |
|
| Status: |
Abandoned in place |
|
CAS Code: |
|
| Regulated Status: |
Federal |
|
Removed Date: |
|
|
OSFM
First Notify Date: |
4/9/1986 |
|
Abandoned Material: |
Inert material mixed with portland cement |
| Current Age: |
41 |
|
Abandoned Date: |
1/15/2020 |
| Install Date: |
1/31/1985 |
|
Red Tag Issue Date: |
|
| Last Used Date: |
3/5/2020 |
|
Fee Due: |
$0.00 |
| Product Date: |
|
|
|
|
Equipment Information
| Equipment Type |
Equipment |
Last Passing Date |
Test Expire Date |
|
Corrosion Prot - Piping
|
Sacrificial Anode Cathodic Protection |
7/30/2019 |
7/30/2022 |
|
Corrosion Prot - Piping
|
Isolation Boots Flex Connector |
Not applicable |
Not applicable |
|
Corrosion Prot - Piping
|
Fiberglass Non-Corrosive |
Not applicable |
Not applicable |
|
Corrosion Prot - Tank
|
Sacrificial Anode Cathodic Protection |
5/29/2019 |
5/29/2022 |
|
Leak Detect - Piping
|
Electronic Pressurized Line Leak Detection |
5/29/2019 |
5/29/2020 |
|
Leak Detect - Tank
|
Automatic Tank Gauging Incon TS 550 with SCALD |
5/29/2019 |
5/29/2020 |
|
Overfill Prev Device
|
Ball Float Vent Valve |
5/29/2019 |
5/29/2022 |
|
Piping
|
Fiberglass Single Wall Piping |
Not applicable |
Not applicable |
|
Piping
|
Single Wall STP/Tanktop Sump |
Not applicable |
Not applicable |
Leak Detect - Piping
|
Piping Sump Sensors Not Regulated Not Required |
Not applicable |
Not applicable |
|
Spill Contain Device
|
Single Wall Spill Bucket |
5/28/2019 |
5/28/2022 |
|
Tank
|
STIP3 Single Wall |
Not applicable |
Not applicable |
|
Vent, Riser, Fill Piping
|
Steel risers |
Not applicable |
Not applicable |
Additional Tests
| Equipment Type |
Equipment |
Test Type |
Test Result |
Test Date |
|
Leak Detect - Tank
|
SIR and Prec Tightness Testing
|
Precision Test (Tank)
|
Pass
|
7/28/2016
|
|
Tank
|
STIP3 Single Wall
|
Precision Test (Tank)
|
Fail
|
10/24/2019
|
Tank Number 2
| Capacity: |
12000 |
|
Petroleum Use: |
|
| Product: |
Gasoline - Premium |
|
CERCLA Substance: |
|
| Status: |
Currently in use |
|
CAS Code: |
|
| Regulated Status: |
Federal |
|
Removed Date: |
|
|
OSFM
First Notify Date: |
4/9/1986 |
|
Abandoned Material: |
|
| Current Age: |
41 |
|
Abandoned Date: |
|
| Install Date: |
1/31/1985 |
|
Red Tag Issue Date: |
|
| Last Used Date: |
|
|
Fee Due: |
$0.00 |
| Product Date: |
|
|
|
|
Equipment Information
| Equipment Type |
Equipment |
Last Passing Date |
Test Expire Date |
|
Corrosion Prot - Piping
|
Sacrificial Anode Flex Connector |
1/8/2025 |
1/8/2028 |
|
Corrosion Prot - Piping
|
Fiberglass Non-Corrosive |
Not applicable |
Not applicable |
|
Corrosion Prot - Tank
|
Sacrificial Anode Cathodic Protection |
1/8/2025 |
1/8/2028 |
|
Leak Detect - Piping
|
Electronic Pressurized Line Leak Detection |
9/2/2025 |
9/2/2026 |
|
Leak Detect - Tank
|
Automatic Tank Gauging Incon TS 550 with SCALD |
9/2/2025 |
9/2/2026 |
|
Overfill Prev Device
|
Ball Only Removed Ball Float Vent Valve |
Not applicable |
Not applicable |
|
Overfill Prev Device
|
Overfill Drop Tube Valve |
1/8/2025 |
1/8/2028 |
|
Piping
|
Fiberglass Single Wall Piping |
Not applicable |
Not applicable |
|
Piping
|
Single Wall STP/Tanktop Sump |
Not applicable |
Not applicable |
Leak Detect - Piping
|
Piping Sump Sensors Not Regulated Not Required |
Not applicable |
Not applicable |
|
Spill Contain Device
|
Single Wall Spill Bucket |
9/30/2024 |
9/30/2027 |
|
Tank
|
STIP3 Single Wall |
Not applicable |
Not applicable |
|
Vent, Riser, Fill Piping
|
Steel risers |
Not applicable |
Not applicable |
Additional Tests
| Equipment Type |
Equipment |
Test Type |
Test Result |
Test Date |
|
Piping
|
Fiberglass Single Wall Piping
|
Precision Test (Piping)
|
Pass
|
1/5/2023
|
|
Leak Detect - Tank
|
SIR and Prec Tightness Testing
|
Precision Test (Tank)
|
Pass
|
7/28/2016
|
Tank Number 3
| Capacity: |
12000 |
|
Petroleum Use: |
|
| Product: |
Gasoline - Regular |
|
CERCLA Substance: |
|
| Status: |
Currently in use |
|
CAS Code: |
|
| Regulated Status: |
Federal |
|
Removed Date: |
|
|
OSFM
First Notify Date: |
4/9/1986 |
|
Abandoned Material: |
|
| Current Age: |
41 |
|
Abandoned Date: |
|
| Install Date: |
1/31/1985 |
|
Red Tag Issue Date: |
|
| Last Used Date: |
|
|
Fee Due: |
$0.00 |
| Product Date: |
|
|
|
|
Equipment Information
| Equipment Type |
Equipment |
Last Passing Date |
Test Expire Date |
|
Corrosion Prot - Piping
|
Sacrificial Anode Flex Connector |
1/8/2025 |
1/8/2028 |
|
Corrosion Prot - Piping
|
Fiberglass Non-Corrosive |
Not applicable |
Not applicable |
|
Corrosion Prot - Tank
|
Sacrificial Anode Cathodic Protection |
1/8/2025 |
1/8/2028 |
|
Leak Detect - Piping
|
Electronic Pressurized Line Leak Detection |
9/2/2025 |
9/2/2026 |
|
Leak Detect - Tank
|
Automatic Tank Gauging Incon TS 550 with SCALD |
9/2/2025 |
9/2/2026 |
|
Overfill Prev Device
|
Ball Float Vent Valve |
1/8/2025 |
1/8/2028 |
|
Piping
|
Fiberglass Single Wall Piping |
Not applicable |
Not applicable |
|
Piping
|
Single Wall STP/Tanktop Sump |
Not applicable |
Not applicable |
Leak Detect - Piping
|
Piping Sump Sensors Not Regulated Not Required |
Not applicable |
Not applicable |
|
Spill Contain Device
|
Single Wall Spill Bucket |
9/30/2024 |
9/30/2027 |
|
Tank
|
STIP3 Single Wall |
Not applicable |
Not applicable |
|
Vent, Riser, Fill Piping
|
Steel risers |
Not applicable |
Not applicable |
Additional Tests
| Equipment Type |
Equipment |
Test Type |
Test Result |
Test Date |
|
Piping
|
Fiberglass Single Wall Piping
|
Precision Test (Piping)
|
Pass
|
12/27/2021
|
|
Leak Detect - Tank
|
SIR and Prec Tightness Testing
|
Precision Test (Tank)
|
Pass
|
7/28/2016
|
|
Tank
|
STIP3 Single Wall
|
Precision Test (Tank)
|
Pass
|
8/18/2025
|
Tank Number 4
| Capacity: |
10000 |
|
Petroleum Use: |
None |
| Product: |
B-11 |
|
CERCLA Substance: |
|
| Status: |
Currently in use |
|
CAS Code: |
|
| Regulated Status: |
Federal |
|
Removed Date: |
|
|
OSFM
First Notify Date: |
4/9/1986 |
|
Abandoned Material: |
|
| Current Age: |
41 |
|
Abandoned Date: |
|
| Install Date: |
1/31/1985 |
|
Red Tag Issue Date: |
|
| Last Used Date: |
|
|
Fee Due: |
$0.00 |
| Product Date: |
|
|
|
|
Equipment Information
| Equipment Type |
Equipment |
Last Passing Date |
Test Expire Date |
|
Corrosion Prot - Piping
|
Sacrificial Anode Flex Connector |
1/8/2025 |
1/8/2028 |
|
Corrosion Prot - Piping
|
Fiberglass Non-Corrosive |
Not applicable |
Not applicable |
|
Corrosion Prot - Tank
|
Sacrificial Anode Cathodic Protection |
1/8/2025 |
1/8/2028 |
|
Leak Detect - Piping
|
Electronic Pressurized Line Leak Detection |
9/2/2025 |
9/2/2026 |
|
Leak Detect - Tank
|
Automatic Tank Gauging Incon TS 550 with SCALD |
9/2/2025 |
9/2/2026 |
|
Overfill Prev Device
|
Ball Float Vent Valve |
1/8/2025 |
1/8/2028 |
|
Piping
|
Fiberglass Single Wall Piping |
Not applicable |
Not applicable |
|
Piping
|
Single Wall STP/Tanktop Sump |
Not applicable |
Not applicable |
Leak Detect - Piping
|
Piping Sump Sensors Not Regulated Not Required |
Not applicable |
Not applicable |
|
Spill Contain Device
|
Single Wall Spill Bucket |
9/30/2024 |
9/30/2027 |
|
Tank
|
STIP3 Single Wall |
Not applicable |
Not applicable |
|
Vent, Riser, Fill Piping
|
Steel risers |
Not applicable |
Not applicable |
Additional Tests
| Equipment Type |
Equipment |
Test Type |
Test Result |
Test Date |
|
Piping
|
Fiberglass Single Wall Piping
|
Precision Test (Piping)
|
Pass
|
12/27/2021
|
|
Leak Detect - Tank
|
SIR and Prec Tightness Testing
|
Precision Test (Tank)
|
Pass
|
7/28/2016
|
Tank Number 5
| Capacity: |
6000 |
|
Petroleum Use: |
|
| Product: |
Kerosene |
|
CERCLA Substance: |
|
| Status: |
Currently in use |
|
CAS Code: |
|
| Regulated Status: |
Federal |
|
Removed Date: |
|
|
OSFM
First Notify Date: |
4/9/1986 |
|
Abandoned Material: |
|
| Current Age: |
41 |
|
Abandoned Date: |
|
| Install Date: |
1/31/1985 |
|
Red Tag Issue Date: |
|
| Last Used Date: |
|
|
Fee Due: |
$0.00 |
| Product Date: |
|
|
|
|
Equipment Information
| Equipment Type |
Equipment |
Last Passing Date |
Test Expire Date |
|
Corrosion Prot - Piping
|
Sacrificial Anode Flex Connector |
1/8/2025 |
1/8/2028 |
|
Corrosion Prot - Piping
|
Fiberglass Non-Corrosive |
Not applicable |
Not applicable |
|
Corrosion Prot - Tank
|
Sacrificial Anode Cathodic Protection |
1/8/2025 |
1/8/2028 |
|
Leak Detect - Piping
|
Electronic Pressurized Line Leak Detection |
9/2/2025 |
9/2/2026 |
|
Leak Detect - Tank
|
Automatic Tank Gauging Incon TS 550 with SCALD |
9/2/2025 |
9/2/2026 |
|
Overfill Prev Device
|
Ball Float Vent Valve |
1/8/2025 |
1/8/2028 |
|
Piping
|
Fiberglass Single Wall Piping |
Not applicable |
Not applicable |
|
Piping
|
Single Wall STP/Tanktop Sump |
Not applicable |
Not applicable |
Leak Detect - Piping
|
Piping Sump Sensors Not Regulated Not Required |
Not applicable |
Not applicable |
|
Spill Contain Device
|
Single Wall Spill Bucket |
9/30/2024 |
9/30/2027 |
|
Tank
|
STIP3 Single Wall |
Not applicable |
Not applicable |
|
Vent, Riser, Fill Piping
|
Steel risers |
Not applicable |
Not applicable |
Additional Tests
| Equipment Type |
Equipment |
Test Type |
Test Result |
Test Date |
|
Piping
|
Fiberglass Single Wall Piping
|
Precision Test (Piping)
|
Pass
|
12/27/2021
|
|
Leak Detect - Tank
|
SIR and Prec Tightness Testing
|
Precision Test (Tank)
|
Pass
|
7/28/2016
|
Failed test = the latest test has failed.
Not applicable = a test does not apply to this equipment type or configuration.
No passing test found = a passing test is expected but was not found from the source data.
MFD
Motorfuel Dispensing Forms
No Forms Found