Owner Summary
Click for Facility/Tank Ownership history
| Owner Number |
Owner Name |
Owner Status |
Purchase Date |
| U0032532 |
PDV Services, LLC |
Current Owner |
12/28/2004 |
| U0023849 |
Kiel Brothers Oil Company, Inc. |
Former Owner |
7/1/1994 |
| U0003073 |
Clark Retail Enterprises, Inc. |
Former Owner |
12/31/1967 |
Notice of Violations (Current)
No Notice of Violations Found
IEMA Numbers Associated with the Facility
| IEMA Number |
Inspection Date |
Inspection Type |
Permit Number |
| 10-1159 |
11/10/2010 |
Removal Log |
01221-2010REM |
| 10-1159 |
11/9/2010 |
Removal Log |
01221-2010REM |
LUST
Fund Eligibility and Deductibility Determinations
| IEMA Number |
Status |
OSFM Received Date |
OSFM Response Date |
Deductible |
Letter |
| 10-1159 |
Eligible |
11/19/2010
|
1/5/2011
|
$5,000
|
|
| 10-1159 |
Withdrawn |
5/10/2012
|
6/15/2012
|
$Not Selected
|
|
Tank Number 1
| Capacity: |
10000 |
|
Petroleum Use: |
|
| Product: |
Gasoline |
|
CERCLA Substance: |
|
| Status: |
Removed |
|
CAS Code: |
|
| Regulated Status: |
Federal |
|
Removed Date: |
11/10/2010 |
|
OSFM
First Notify Date: |
5/2/1986 |
|
Abandoned Material: |
|
| Current Age: |
31 |
|
Abandoned Date: |
|
| Install Date: |
1/1/1979 |
|
Red Tag Issue Date: |
|
| Last Used Date: |
|
|
Fee Due: |
$0.00 |
| Product Date: |
1/1/1979 |
|
|
|
Equipment Information
| Equipment Type |
Equipment |
Last Passing Date |
Test Expire Date |
|
Corrosion Prot - Piping
|
Fiberglass Non-Corrosive |
Not applicable |
Not applicable |
|
Corrosion Prot - Piping
|
Fiberglass Non-Corrosive |
Not applicable |
Not applicable |
|
Corrosion Prot - Tank
|
Lining Materials Internal |
No passing test found |
No passing test found |
|
Leak Detect - Piping
|
Pressurized Line Leak Detection |
No passing test found |
No passing test found |
|
Leak Detect - Tank
|
Automatic Tank Gauging Veeder Root TLS 350 |
No passing test found |
No passing test found |
|
Leak Detect - Tank
|
Automatic Tank Gauging Veeder Root CSLD option only |
No passing test found |
No passing test found |
|
Leak Detect - Tank
|
Automatic Tank Gauging |
No passing test found |
No passing test found |
|
Leak Detect - Tank
|
Monthly Inv Ctrl and Prec Tight Testing |
No passing test found |
No passing test found |
|
Overfill Prev Device
|
Ball Float Vent Valve |
No passing test found |
No passing test found |
|
Piping
|
Fiberglass Single Wall Piping |
Not applicable |
Not applicable |
|
Piping
|
Fiberglass Single Wall Piping |
Not applicable |
Not applicable |
|
Spill Contain Device
|
Manhole Field Constructed |
No passing test found |
No passing test found |
|
Tank
|
Steel Single Wall |
Not applicable |
Not applicable |
Additional Tests
No Tests Listed
Tank Number 2
| Capacity: |
9400 |
|
Petroleum Use: |
|
| Product: |
Gasoline |
|
CERCLA Substance: |
|
| Status: |
Removed |
|
CAS Code: |
|
| Regulated Status: |
Federal |
|
Removed Date: |
11/9/2010 |
|
OSFM
First Notify Date: |
5/2/1986 |
|
Abandoned Material: |
|
| Current Age: |
31 |
|
Abandoned Date: |
|
| Install Date: |
1/1/1979 |
|
Red Tag Issue Date: |
|
| Last Used Date: |
|
|
Fee Due: |
$0.00 |
| Product Date: |
1/1/1979 |
|
|
|
Equipment Information
| Equipment Type |
Equipment |
Last Passing Date |
Test Expire Date |
|
Corrosion Prot - Piping
|
Fiberglass Non-Corrosive |
Not applicable |
Not applicable |
|
Corrosion Prot - Piping
|
Fiberglass Non-Corrosive |
Not applicable |
Not applicable |
|
Corrosion Prot - Tank
|
Lining Materials Internal |
No passing test found |
No passing test found |
|
Leak Detect - Piping
|
Pressurized Line Leak Detection |
No passing test found |
No passing test found |
|
Leak Detect - Tank
|
Automatic Tank Gauging Veeder Root TLS 350 |
No passing test found |
No passing test found |
|
Leak Detect - Tank
|
Automatic Tank Gauging Veeder Root CSLD option only |
No passing test found |
No passing test found |
|
Leak Detect - Tank
|
Automatic Tank Gauging |
No passing test found |
No passing test found |
|
Leak Detect - Tank
|
Monthly Inv Ctrl and Prec Tight Testing |
No passing test found |
No passing test found |
|
Overfill Prev Device
|
Ball Float Vent Valve |
No passing test found |
No passing test found |
|
Piping
|
Fiberglass Single Wall Piping |
Not applicable |
Not applicable |
|
Piping
|
Fiberglass Single Wall Piping |
Not applicable |
Not applicable |
|
Spill Contain Device
|
Manhole Field Constructed |
No passing test found |
No passing test found |
|
Tank
|
Steel Single Wall |
Not applicable |
Not applicable |
Additional Tests
No Tests Listed
Failed test = the latest test has failed.
Not applicable = a test does not apply to this equipment type or configuration.
No passing test found = a passing test is expected but was not found from the source data.
Dispenser Information
Failed test = the latest test has failed.
Not applicable = a test does not apply to this equipment type or configuration.
No passing test found = a passing test is expected but was not found from the source data.
MFD
Motorfuel Dispensing Forms
No Forms Found