Facility Details
Facility Number:
7009996
Status:
Closed
Facility Name:
Knapp Mart
Address:
511 W. Main Street
West Frankfort, IL 62896
County:
Franklin
Property Parcel:
Facility Type:
Attended Self-Service Station
Owner Type:
Private
Green Tag Decal:
S000160
Green Tag Issue Date:
7/11/2017
Green Tag Expiration Date:
12/31/2019
Owner Details
Owner Name:
Knapp Oil Company, Inc.
Owner Address:
P.O. Box 215
Xenia, IL 62899
Owner Status:
Current Owner
Purchase Date:
Type of Financial Responsibility:
Self-Insurance
Financial Responsibility Reporting Due Date:
6/29/2019
Motor Fuel Dispensing Permits
MFD Permit Type
Issue Date
Expiration Date
Self Service
7/11/2017
12/31/2019
Owner Summary
Click for Facility/Tank Ownership history
Owner Number
Owner Name
Owner Status
Purchase Date
U0008547
Knapp Oil Company, Inc.
Current Owner
U0008549
Knapp Oil Company, Inc.
Former Owner
1/30/1998
U0003073
Clark Retail Enterprises, Inc.
Former Owner
12/31/1967
Permits (Unexpired)
Click for permit history
No Active Permits Found
Notice of Violations (Current)
No Notice of Violations Found
IEMA Numbers Associated with the Facility
IEMA Number
Inspection Date
Inspection Type
Permit Number
18-0764
9/20/2018
Removal Log
01179-2018REM
LUST
Fund Eligibility and Deductibility Determinations
IEMA Number
Status
OSFM Received Date
OSFM Response Date
Deductible
Letter
20180764
Eligible
10/15/2018
10/18/2018
$5,000
Letter
Pay Tank Fees Online
Tank Information
Tank Number 1
Capacity:
7500
Petroleum Use:
Product:
Gasoline
CERCLA Substance:
Status:
Removed
CAS Code:
Regulated Status:
Federal
Removed Date:
9/20/2018
OSFM
First Notify Date:
5/2/1986
Abandoned Material:
Current Age:
47
Abandoned Date:
Install Date:
5/2/1971
Red Tag Issue Date:
Last Used Date:
10/20/2017
Fee Due:
$0.00
Product Date:
Equipment
Equipment Type
Equipment
Last Passing Date
Test Expire Date
Corrosion Prot - Piping
Sacrificial Anode Cathodic Protection
8/2/2016
8/2/2019
Corrosion Prot - Piping
Fiberglass Non-Corrosive
N/A
N/A
Corrosion Prot - Tank
Lining Materials Internal
9/17/2013
9/17/2018
Leak Detect - Piping
Mechanical Pressurized Line Leak Detection
8/2/2016
8/2/2017
Leak Detect - Tank
Ground Water Monitoring Wells
Overfill Prev Device
Ball Float Vent Valve OPW 53VM
Piping
Fiberglass Single Wall Piping
N/A
N/A
Spill Contain Device
Single Wall Spill Bucket
Tank
Steel Single Wall
N/A
N/A
Additional Tests
Equipment Type
Equipment
Test Type
Test Result
Test Date
Tank Number 2
Capacity:
7500
Petroleum Use:
Product:
Gasoline
CERCLA Substance:
Status:
Removed
CAS Code:
Regulated Status:
Federal
Removed Date:
9/20/2018
OSFM
First Notify Date:
5/2/1986
Abandoned Material:
Current Age:
47
Abandoned Date:
Install Date:
5/2/1971
Red Tag Issue Date:
Last Used Date:
10/20/2017
Fee Due:
$0.00
Product Date:
Equipment
Equipment Type
Equipment
Last Passing Date
Test Expire Date
Corrosion Prot - Piping
Sacrificial Anode Cathodic Protection
8/2/2016
8/2/2019
Corrosion Prot - Piping
Fiberglass Non-Corrosive
N/A
N/A
Corrosion Prot - Tank
Lining Materials Internal
9/17/2013
9/17/2018
Leak Detect - Piping
Mechanical Pressurized Line Leak Detection
8/2/2016
8/2/2017
Leak Detect - Tank
Ground Water Monitoring Wells
Overfill Prev Device
Ball Float Vent Valve OPW 53VM
Piping
Fiberglass Single Wall Piping
N/A
N/A
Spill Contain Device
Single Wall Spill Bucket
Tank
Steel Single Wall
N/A
N/A
Additional Tests
Equipment Type
Equipment
Test Type
Test Result
Test Date
Tank Number 3
Capacity:
7500
Petroleum Use:
Product:
E85
CERCLA Substance:
Status:
Removed
CAS Code:
Regulated Status:
Federal
Removed Date:
9/20/2018
OSFM
First Notify Date:
5/2/1986
Abandoned Material:
Current Age:
47
Abandoned Date:
Install Date:
5/2/1971
Red Tag Issue Date:
Last Used Date:
10/20/2017
Fee Due:
$0.00
Product Date:
Equipment
Equipment Type
Equipment
Last Passing Date
Test Expire Date
Corrosion Prot - Piping
Sacrificial Anode Cathodic Protection
8/2/2016
8/2/2019
Corrosion Prot - Piping
Fiberglass Non-Corrosive
N/A
N/A
Corrosion Prot - Tank
Lining Materials Internal
9/18/2013
9/18/2018
Leak Detect - Piping
Mechanical Pressurized Line Leak Detection
8/2/2016
8/2/2017
Leak Detect - Tank
Ground Water Monitoring Wells
Overfill Prev Device
Ball Float Vent Valve OPW 53VM
Piping
Fiberglass Single Wall Piping
N/A
N/A
Spill Contain Device
Single Wall Spill Bucket
Tank
Steel Single Wall
N/A
N/A
Additional Tests
Equipment Type
Equipment
Test Type
Test Result
Test Date
Dispenser Information
MFD
Motorfuel Dispensing Forms
No Forms Found