Information
JB Pritzker, Governor
James A. Rivera, State Fire Marshal
Division of Petroleum & Chemical Safety
State of Illinois
Employment Opportunities
Ready Illinois
Find us on Facebook
UST
Search
Contractor Search
Permit Search
Disclaimer & Rules/Statutes
Disclaimer
Rules
Statutes
Statistics & Reports
Statistics
Red Tag Tanks
Blended Fuel Tanks
Federal Energy Act Reports
Help
Division of Petroleum & Chemical Safety
Facility Details
Facility Number:
7009255
Status:
Closed
Facility Name:
Grayville Shell Plaza
Address:
1814 South Court, I-64 & Illinois Route 1
Grayville, IL 62844
County:
Edwards
Property Parcel:
Facility Type:
Attended Self-Service Station
Owner Type:
Private
Green Tag Decal:
R005649
Green Tag Issue Date:
9/27/2016
Green Tag Expiration Date:
12/31/2018
Owner Details
Owner Name:
Dersch Energies, Inc.
Owner Address:
620 Oak Street
P.O. Box 217
Mount Carmel, IL 62863
Owner Status:
Current Owner
Purchase Date:
Type of Financial Responsibility:
Certificate of Deposit
Financial Responsibility Reporting Due Date:
9/27/2020
Motor Fuel Dispensing Permits
MFD Permit Type
Issue Date
Expiration Date
Self Service
9/27/2016
12/31/2018
Owner Summary
Click for Facility/Tank Ownership history
Owner Number
Owner Name
Owner Status
Purchase Date
U0004025
Dersch Energies, Inc.
Current Owner
Permits (Unexpired)
Click for permit history
No Active Permits Found
Notice of Violations (Current)
No Notice of Violations Found
IEMA Numbers Associated with the Facility
IEMA Number
Inspection Date
Inspection Type
Permit Number
2019-1001
10/8/2019
Removal Log
01849-2019REM
2019-1001
10/9/2019
Removal Log
01849-2019REM
LUST
Fund Eligibility and Deductibility Determinations
IEMA Number
Status
OSFM Received Date
OSFM Response Date
Deductible
Letter
20191001
Eligible
12/10/2019
12/12/2019
$5,000
Letter
Pay Tank Fees Online
Tank Information
Tank Number 1
Capacity:
7896
Petroleum Use:
Product:
Gasoline
CERCLA Substance:
Status:
Removed
CAS Code:
Regulated Status:
Federal
Removed Date:
10/8/2019
OSFM
First Notify Date:
5/3/1986
Abandoned Material:
Current Age:
42
Abandoned Date:
Install Date:
1/1/1977
Red Tag Issue Date:
Last Used Date:
7/27/2018
Fee Due:
$0.00
Product Date:
Equipment
Equipment Type
Equipment
Last Passing Date
Test Expire Date
Corrosion Prot - Piping
Impressed Current Cathodic Protection
9/22/2016
9/22/2017
Corrosion Prot - Tank
Impressed Current Cathodic Protection
9/22/2016
9/22/2017
Leak Detect - Piping
Mechanical Pressurized Line Leak Detection
8/11/2016
8/11/2017
Leak Detect - Tank
Automatic Tank Gauging Veeder Root TLS 350 with CSLD
Overfill Prev Device
Overfill Drop Tube Valve
Piping
Steel Single Wall Piping
N/A
N/A
Spill Contain Device
Single Wall Spill Bucket
Tank
Steel Single Wall
N/A
N/A
Additional Tests
Equipment Type
Equipment
Test Type
Test Result
Test Date
Tank Number 2
Capacity:
7896
Petroleum Use:
Product:
Gasoline
CERCLA Substance:
Status:
Removed
CAS Code:
Regulated Status:
Federal
Removed Date:
10/8/2019
OSFM
First Notify Date:
5/3/1986
Abandoned Material:
Current Age:
42
Abandoned Date:
Install Date:
1/1/1977
Red Tag Issue Date:
Last Used Date:
7/27/2018
Fee Due:
$0.00
Product Date:
1/1/1977
Equipment
Equipment Type
Equipment
Last Passing Date
Test Expire Date
Corrosion Prot - Piping
Impressed Current Cathodic Protection
9/22/2016
9/22/2017
Corrosion Prot - Tank
Impressed Current Cathodic Protection
9/22/2016
9/22/2017
Leak Detect - Piping
Mechanical Pressurized Line Leak Detection
8/11/2016
8/11/2017
Leak Detect - Tank
Automatic Tank Gauging Veeder Root TLS 350 with CSLD
Overfill Prev Device
Overfill Drop Tube Valve
Piping
Steel Single Wall Piping
N/A
N/A
Spill Contain Device
Single Wall Spill Bucket
Tank
Steel Single Wall
N/A
N/A
Additional Tests
Equipment Type
Equipment
Test Type
Test Result
Test Date
Tank Number 3
Capacity:
7896
Petroleum Use:
Product:
Gasoline
CERCLA Substance:
Status:
Removed
CAS Code:
Regulated Status:
Federal
Removed Date:
10/8/2019
OSFM
First Notify Date:
5/3/1986
Abandoned Material:
Current Age:
42
Abandoned Date:
Install Date:
1/1/1977
Red Tag Issue Date:
Last Used Date:
7/27/2018
Fee Due:
$0.00
Product Date:
1/1/1977
Equipment
Equipment Type
Equipment
Last Passing Date
Test Expire Date
Corrosion Prot - Piping
Impressed Current Cathodic Protection
9/22/2016
9/22/2017
Corrosion Prot - Tank
Impressed Current Cathodic Protection
9/22/2016
9/22/2017
Leak Detect - Piping
Mechanical Pressurized Line Leak Detection
8/11/2016
8/11/2017
Leak Detect - Tank
Automatic Tank Gauging Veeder Root TLS 350 with CSLD
Overfill Prev Device
Overfill Drop Tube Valve
Piping
Steel Single Wall Piping
N/A
N/A
Spill Contain Device
Single Wall Spill Bucket
Tank
Steel Single Wall
N/A
N/A
Additional Tests
Equipment Type
Equipment
Test Type
Test Result
Test Date
Tank Number 4
Capacity:
10152
Petroleum Use:
Product:
Diesel Fuel
CERCLA Substance:
Status:
Removed
CAS Code:
Regulated Status:
Federal
Removed Date:
10/9/2019
OSFM
First Notify Date:
5/3/1986
Abandoned Material:
Current Age:
42
Abandoned Date:
Install Date:
1/1/1977
Red Tag Issue Date:
Last Used Date:
7/27/2018
Fee Due:
$0.00
Product Date:
1/1/1977
Equipment
Equipment Type
Equipment
Last Passing Date
Test Expire Date
Corrosion Prot - Piping
Impressed Current Cathodic Protection
9/22/2016
9/22/2017
Corrosion Prot - Tank
Impressed Current Cathodic Protection
9/22/2016
9/22/2017
Leak Detect - Piping
Mechanical Pressurized Line Leak Detection
8/11/2016
8/11/2017
Leak Detect - Tank
Automatic Tank Gauging Veeder Root TLS 350 with CSLD
Overfill Prev Device
Overfill Drop Tube Valve
Piping
Steel Single Wall Piping
N/A
N/A
Spill Contain Device
Single Wall Spill Bucket
Tank
Steel Single Wall
N/A
N/A
Additional Tests
Equipment Type
Equipment
Test Type
Test Result
Test Date
Tank Number 5
Capacity:
2000
Petroleum Use:
Consumptive Use on Premises for Heating
Product:
Heating Oil
CERCLA Substance:
Status:
Removed
CAS Code:
Regulated Status:
State
Removed Date:
10/8/2019
OSFM
First Notify Date:
5/3/1986
Abandoned Material:
Current Age:
42
Abandoned Date:
Install Date:
1/1/1977
Red Tag Issue Date:
Last Used Date:
Fee Due:
$0.00
Product Date:
Equipment
Equipment Type
Equipment
Last Passing Date
Test Expire Date
Corrosion Prot - Piping
Impressed Current Cathodic Protection
Corrosion Prot - Tank
Impressed Current Cathodic Protection
Tank
STIP3 Single Wall
N/A
N/A
Additional Tests
Equipment Type
Equipment
Test Type
Test Result
Test Date
Dispenser Information
MFD
Motorfuel Dispensing Forms
No Forms Found