Information
JB Pritzker, Governor
James A. Rivera, State Fire Marshal
Division of Petroleum & Chemical Safety
State of Illinois
Employment Opportunities
Ready Illinois
Find us on Facebook
UST
Search
Contractor Search
Permit Search
Disclaimer & Rules/Statutes
Disclaimer
Rules
Statutes
Statistics & Reports
Statistics
Red Tag Tanks
Blended Fuel Tanks
Federal Energy Act Reports
Help
Division of Petroleum & Chemical Safety
Facility Details
Facility Number:
7008170
Status:
Closed
Facility Name:
Former Jerry Johnson Siding
Address:
605 Main Street
Goreville, IL 62939
County:
Johnson
Property Parcel:
Facility Type:
Commercial / Retail
Owner Type:
Private
Green Tag Decal:
D004484
Green Tag Issue Date:
3/6/2002
Green Tag Expiration Date:
12/31/2005
Owner Details
Owner Name:
Lisa Hudson
Owner Address:
598 S. Wolf Creek Road
Carbondale, IL 62902
Owner Status:
Current Owner
Purchase Date:
5/22/2013
Type of Financial Responsibility:
Designated Savings Account
Financial Responsibility Reporting Due Date:
6/24/2014
Motor Fuel Dispensing Permits
No MFD Permits Found
Owner Summary
Click for Facility/Tank Ownership history
Owner Number
Owner Name
Owner Status
Purchase Date
U0036919
Hudson, Lisa
Current Owner
5/22/2013
U0007871
Johnson, Jerry
Former Owner
Permits (Unexpired)
Click for permit history
No Active Permits Found
Notice of Violations (Current)
No Notice of Violations Found
IEMA Numbers Associated with the Facility
IEMA Number
Inspection Date
Inspection Type
Permit Number
13-0753
8/6/2013
Removal Log
00680-2013REM
LUST
Fund Eligibility and Deductibility Determinations
IEMA Number
Status
OSFM Received Date
OSFM Response Date
Deductible
Letter
13-0753
Eligible
7/15/2013
8/13/2013
$5,000
Pay Tank Fees Online
Tank Information
Tank Number 1
Capacity:
1000
Petroleum Use:
Product:
Diesel Fuel
CERCLA Substance:
Status:
Removed
CAS Code:
Regulated Status:
Federal
Removed Date:
8/6/2013
OSFM
First Notify Date:
4/25/1986
Abandoned Material:
Current Age:
23
Abandoned Date:
Install Date:
Red Tag Issue Date:
Last Used Date:
4/1/2005
Fee Due:
$0.00
Product Date:
Equipment
Equipment Type
Equipment
Last Passing Date
Test Expire Date
Corrosion Prot - Piping
Fiberglass Non-Corrosive
N/A
N/A
Corrosion Prot - Tank
STIP3 Cathodic Protection with Dielectric Coating
8/3/2001
8/3/2004
Leak Detect - Piping
European with No Test Req Suction
N/A
N/A
Leak Detect - Tank
Manual Tank Gauging
N/A
N/A
Overfill Prev Device
Overfill Drop Tube Valve
Piping
Fiberglass Single Wall Piping Ameron
N/A
N/A
Spill Contain Device
Manhole Field Constructed
Tank
STIP3 Single Wall
N/A
N/A
Additional Tests
Equipment Type
Equipment
Test Type
Test Result
Test Date
Dispenser Information
MFD
Motorfuel Dispensing Forms
No Forms Found