Division of Petroleum & Chemical Safety

 

Facility Details

Facility Number: 7008002
Status: Closed
Facility Name: Circle K #146
Address: 101 Potomac Blvd. Mount Vernon, IL 62864
County: Jefferson
Property Parcel:
Facility Type: Attended Self-Service Station
Owner Type: Private
Green Tag Decal: O003153
Green Tag Issue Date: 5/28/2013
Green Tag Expire Date: 12/31/2015
MFD Type: N/A

Owner Details

Owner Name: Mac's Convenience Stores, LLC
Owner Address: 1100 Situs Court, Suite 100 Raleigh, NC 27606
Owner Status: Current Owner
Purchase Date: 7/25/2013
Type of Financial Responsibility: Commercial Insurance
Financial Responsibility Reporting Due Date: 1/7/2016

Owner Summary

Click for Facility/Tank Ownership history
Owner Number Owner Name Owner Status Purchase Date
U0030949 Mac's Convenience Stores, LLC Current Owner 7/25/2013
U0030252 Kooshtard Property II, LLC Former Owner 6/21/2001
U0023515 Johnson Oil Company, L.L.C. Former Owner 8/3/1998
U0008722 L. Keller Oil Properties, Inc. Former Owner 12/31/1967

Permits (Unexpired)

Click for permit history

No Active Permits Found

Notice of Violations (Current)

No Notice of Violations Found

IEMA Numbers Associated with the Facility

IEMA Number Inspection Date Inspection Type Permit Number
13-1100 10/8/2013 Removal Log 00938-2013REM

LUST Fund Eligibility and Deductibility Determinations

IEMA Number Status OSFM Received Date OSFM Response Date Deductible Letter
98-0546 Eligible 4/7/1999 4/27/1999 $10,000
13-1100 Eligible 11/12/2013 11/19/2013 $5,000
Pay Tank Fees Online

Tank Information



Tank Number 1

Capacity: 12000 Petroleum Use:
Product: Gasoline CERCLA Substance:
Status: Removed CAS Code:
Regulated Status: Federal Removed Date: 10/8/2013
OSFM First Notify Date: 4/20/1986 Abandoned Material:
Current Age: 37 Abandoned Date:
Install Date: 4/1/1976 Red Tag Issue Date:
Last Used Date: 6/23/2013 Fee Due: $0.00
Product Date: 4/15/1976

Equipment Information

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Sacrificial Anode Cathodic Protection 9/17/2012 9/17/2015
Corrosion Prot - Tank Impressed Current Cathodic Protection 9/17/2012 9/17/2013
Corrosion Prot - Tank Sacrificial Anode Cathodic Protection 9/17/2012 9/17/2015
Leak Detect - Piping Electronic Pressurized Line Leak Detection 5/20/2013 5/20/2014
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 350 with CSLD No passing test found No passing test found
Overfill Prev Device Overfill Drop Tube Valve No passing test found No passing test found
Piping Fiberglass Double Wall Not applicable Not applicable
Spill Contain Device Single Wall Spill Bucket No passing test found No passing test found
Tank Steel Single Wall Not applicable Not applicable

Additional Tests

No Tests Listed




Tank Number 2

Capacity: 12000 Petroleum Use:
Product: Gasoline CERCLA Substance:
Status: Removed CAS Code:
Regulated Status: Federal Removed Date: 10/8/2013
OSFM First Notify Date: 4/20/1986 Abandoned Material:
Current Age: 37 Abandoned Date:
Install Date: 4/1/1976 Red Tag Issue Date:
Last Used Date: 6/23/2013 Fee Due: $0.00
Product Date: 4/15/1976

Equipment Information

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Sacrificial Anode Cathodic Protection 9/17/2012 9/17/2015
Corrosion Prot - Tank Impressed Current Cathodic Protection 9/17/2012 9/17/2013
Corrosion Prot - Tank Sacrificial Anode Cathodic Protection 9/17/2012 9/17/2015
Leak Detect - Piping Electronic Pressurized Line Leak Detection 5/20/2013 5/20/2014
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 350 with CSLD No passing test found No passing test found
Overfill Prev Device Overfill Drop Tube Valve No passing test found No passing test found
Piping Fiberglass Double Wall Not applicable Not applicable
Spill Contain Device Single Wall Spill Bucket No passing test found No passing test found
Tank Steel Single Wall Not applicable Not applicable

Additional Tests

No Tests Listed




Tank Number 3

Capacity: 6000 Petroleum Use:
Product: Gasoline CERCLA Substance:
Status: Removed CAS Code:
Regulated Status: Federal Removed Date: 10/8/2013
OSFM First Notify Date: 4/20/1986 Abandoned Material:
Current Age: 37 Abandoned Date:
Install Date: 4/1/1976 Red Tag Issue Date:
Last Used Date: 6/23/2013 Fee Due: $0.00
Product Date: 4/15/1976

Equipment Information

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Sacrificial Anode Cathodic Protection 9/17/2012 9/17/2015
Corrosion Prot - Tank Impressed Current Cathodic Protection 9/17/2012 9/17/2013
Leak Detect - Piping Electronic Pressurized Line Leak Detection 5/20/2013 5/20/2014
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 350 with CSLD No passing test found No passing test found
Overfill Prev Device Overfill Drop Tube Valve No passing test found No passing test found
Piping Fiberglass Double Wall Not applicable Not applicable
Spill Contain Device Single Wall Spill Bucket No passing test found No passing test found
Tank Steel Single Wall Not applicable Not applicable

Additional Tests

No Tests Listed


Failed test = the latest test has failed.

Not applicable = a test does not apply to this equipment type or configuration.

No passing test found = a passing test is expected but was not found from the source data.


Dispenser Information




Failed test = the latest test has failed.

Not applicable = a test does not apply to this equipment type or configuration.

No passing test found = a passing test is expected but was not found from the source data.


MFD Motorfuel Dispensing Forms

No Forms Found