Division of Petroleum & Chemical Safety

 

Facility Details

Facility Number: 7007983
Status: Active
Facility Name: Travel Centers of America
Address: 4510 Broadway
PO Box 943
Mount Vernon, IL 62864
County: Jefferson
Property Parcel: 06-35-100-001
Facility Type: Attended Self-Service Station
Owner Type: Private
Green Tag Decal: Z001740
Green Tag Issue Date: 5/1/2024
Green Tag Expiration Date: 12/31/2026

Owner Details

Owner Name: HPT TA Properties, LLC
Owner Address: 24601 Center Ridge Road
Westlake, OH 44145
Owner Status: Current Owner
Purchase Date: 1/31/2007
Type of Financial Responsibility: Commercial Insurance
Financial Responsibility Reporting Due Date: 2/12/2026

Motor Fuel Dispensing Permits

MFD Permit Type Issue Date Expiration Date
Self Service 5/1/2024 12/31/2024

Owner Summary

Click for Facility/Tank Ownership history
Owner Number Owner Name Owner Status Purchase Date
U0034157 HPT TA Properties, LLC Current Owner 1/31/2007
U0026726 TA Operating, LLC Former Owner 4/15/1993
U0015441 The Uno Ven Company Former Owner 12/31/1967

Permits (Unexpired)

Click for permit history

No Active Permits Found

Notice of Violations (Current)

NOV Number: E0020243287 (Pending)    Issue Date: 12/18/2024    Expiration Date: 2/16/2025    View NOV Form

Tanks Violation
10 Tank monitor does not appear to function properly and requires maintenance. - Tank monitor failed annual inspection, repair/replace.

NOV Number: E0020250654 (Pending)    Issue Date: 3/13/2025    Expiration Date: 5/12/2025    View NOV Form

Tanks Violation
2, 4 Precision line test required. - Failed piping precision test, repair line/leak. Passing precision test required, before piping can be used. Failed tank or line precision tests and defective tank or piping leak detection equipment will require that particular tank system to be shut down until repaired and functioning properly.

IEMA Numbers Associated with the Facility

No IEMA Numbers Found

LUST Fund Eligibility and Deductibility Determinations

No Applications Found

Pay Tank Fees Online

Tank Information



Tank Number 2

Capacity: 20000 Petroleum Use:
Product: Diesel Fuel CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 4/14/1986 Abandoned Material:
Current Age: 48 Abandoned Date:
Install Date: 1/1/1977 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 1/1/1977

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Isolation Boots Flex Connector N/A N/A
Corrosion Prot - Piping Fiberglass Non-Corrosive N/A N/A
Corrosion Prot - Tank Fiberglass Non-Corrosive N/A N/A
Leak Detect - Piping Mechanical Pressurized Line Leak Detection 7/2/2024 7/2/2025
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 350 Plus with CSLD 7/2/2024 7/2/2025
Leak Detect - Tank SIR and Prec Tightness Testing Warren Rogers Assoc. Petro Network S3 Version D 7/6/2023 7/6/2024
Overfill Prev Device Overfill Drop Tube Valve 9/14/2022 9/14/2025
Piping Fiberglass Double Wall Ameron Dualoy 3000/LCX N/A N/A
Piping Single Wall STP/Tanktop Sump 9/20/2022 9/20/2025
Leak Detect - Piping Non-Discriminating Sump Sensor 12/7/2021 12/7/2022
Leak Detect - Piping Sump Sensor with positive shutdown 7/2/2024 7/2/2025
Piping Single Wall Transition Sump 9/20/2022 9/20/2025
Leak Detect - Piping Sump Sensor with positive shutdown 7/2/2024 7/2/2025
Spill Contain Device Double Wall Spill Bucket 9/20/2022 9/20/2025
Tank Fiberglass Single Wall N/A N/A
Vent, Riser, Fill Piping Steel risers N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Fiberglass Double Wall Ameron Dualoy 3000/LCX Precision Test (Piping) Pass 3/13/2025
Tank Fiberglass Single Wall Precision Test (Tank) Pass 7/2/2024



Tank Number 3

Capacity: 20000 Petroleum Use:
Product: Diesel Fuel CERCLA Substance:
Status: Currently in use CAS Code: 68476346
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 4/14/1986 Abandoned Material:
Current Age: 48 Abandoned Date:
Install Date: 1/1/1977 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 1/1/1977

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Isolation Boots Flex Connector N/A N/A
Corrosion Prot - Piping Fiberglass Non-Corrosive N/A N/A
Corrosion Prot - Tank Fiberglass Non-Corrosive N/A N/A
Leak Detect - Piping Mechanical Pressurized Line Leak Detection 7/2/2024 7/2/2025
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 350 Plus with CSLD 7/2/2024 7/2/2025
Leak Detect - Tank SIR and Prec Tightness Testing Warren Rogers Assoc. Petro Network S3 Version D 7/6/2023 7/6/2024
Overfill Prev Device Overfill Drop Tube Valve 9/14/2022 9/14/2025
Piping Fiberglass Double Wall Ameron Dualoy 3000/LCX N/A N/A
Piping Single Wall STP/Tanktop Sump 9/20/2022 9/20/2025
Leak Detect - Piping Non-Discriminating Sump Sensor 12/7/2021 12/7/2022
Leak Detect - Piping Sump Sensor with positive shutdown 7/2/2024 7/2/2025
Spill Contain Device Double Wall Spill Bucket 9/20/2022 9/20/2025
Tank Fiberglass Single Wall N/A N/A
Vent, Riser, Fill Piping Steel risers N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Fiberglass Double Wall Ameron Dualoy 3000/LCX Precision Test (Piping) Pass 3/13/2025
Tank Fiberglass Single Wall Precision Test (Tank) Pass 7/2/2024



Tank Number 4

Capacity: 20000 Petroleum Use:
Product: Diesel Fuel CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 4/14/1986 Abandoned Material:
Current Age: 48 Abandoned Date:
Install Date: 1/1/1977 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 1/1/1977

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Isolation Boots Flex Connector N/A N/A
Corrosion Prot - Piping Fiberglass Non-Corrosive N/A N/A
Corrosion Prot - Tank Fiberglass Non-Corrosive N/A N/A
Leak Detect - Piping Mechanical Pressurized Line Leak Detection 7/2/2024 7/2/2025
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 350 Plus with CSLD 7/2/2024 7/2/2025
Leak Detect - Tank SIR and Prec Tightness Testing Warren Rogers Assoc. Petro Network S3 Version D 7/6/2023 7/6/2024
Overfill Prev Device Overfill Drop Tube Valve 9/14/2022 9/14/2025
Piping Fiberglass Double Wall Ameron Dualoy 3000/LCX N/A N/A
Piping Single Wall STP/Tanktop Sump 9/20/2022 9/20/2025
Leak Detect - Piping Non-Discriminating Sump Sensor 12/7/2021 12/7/2022
Leak Detect - Piping Sump Sensor with positive shutdown 7/2/2024 7/2/2025
Piping Single Wall Transition Sump 9/20/2022 9/20/2025
Leak Detect - Piping Sump Sensor with positive shutdown 7/2/2024 7/2/2025
Spill Contain Device Double Wall Spill Bucket 9/20/2022 9/20/2025
Tank Fiberglass Single Wall N/A N/A
Vent, Riser, Fill Piping Steel risers N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Fiberglass Double Wall Ameron Dualoy 3000/LCX Precision Test (Piping) Pass 3/13/2025
Tank Fiberglass Single Wall Precision Test (Tank) Pass 7/2/2024



Tank Number 5

Capacity: 20000 Petroleum Use:
Product: Gasoline - Regular CERCLA Substance:
Status: Currently in use CAS Code: 8006619
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 4/14/1986 Abandoned Material:
Current Age: 48 Abandoned Date:
Install Date: 1/1/1977 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 1/1/1977

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Sacrificial Anode Flex Connector 8/10/2024 8/10/2027
Corrosion Prot - Piping Fiberglass Non-Corrosive N/A N/A
Corrosion Prot - Tank Fiberglass Non-Corrosive N/A N/A
Leak Detect - Piping Mechanical Pressurized Line Leak Detection 7/2/2024 7/2/2025
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 350 Plus with CSLD 7/2/2024 7/2/2025
Overfill Prev Device Overfill Drop Tube Valve 2/9/2023 2/9/2026
Piping Fiberglass Single Wall Piping N/A N/A
Piping Not Installed STP/Tanktop Sump N/A N/A
Spill Contain Device Double Wall Spill Bucket 9/20/2022 9/20/2025
Tank Fiberglass Single Wall N/A N/A
Vent, Riser, Fill Piping Steel risers N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Fiberglass Single Wall Piping Precision Test (Piping) Pass 7/2/2024
Tank Fiberglass Single Wall Precision Test (Tank) Pass 7/6/2023



Tank Number 6

Capacity: 1000 Petroleum Use:
Product: Used Oil CERCLA Substance:
Status: Removed CAS Code:
Regulated Status: Federal Removed Date: 6/11/1999
OSFM First Notify Date: 4/14/1986 Abandoned Material:
Current Age: 22 Abandoned Date:
Install Date: 1/1/1977 Red Tag Issue Date:
Last Used Date: 12/21/1998 Fee Due: $0.00
Product Date: 1/1/1977

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date



Tank Number 7

Capacity: 10000 Petroleum Use: Consumptive Use on Premises for Heating
Product: Heating Oil CERCLA Substance:
Status: Abandoned in place CAS Code: 68476346
Regulated Status: State Removed Date:
OSFM First Notify Date: 4/14/1986 Abandoned Material: Inert material mixed with portland cement
Current Age: 48 Abandoned Date: 12/13/2006
Install Date: 1/1/1977 Red Tag Issue Date:
Last Used Date: 9/1/2005 Fee Due: $0.00
Product Date:

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date



Tank Number 8

Capacity: 20000 Petroleum Use:
Product: Gasoline - Premium CERCLA Substance:
Status: Currently in use CAS Code: 8006619
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 4/14/1986 Abandoned Material:
Current Age: 48 Abandoned Date:
Install Date: 1/1/1977 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 1/1/1977

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Sacrificial Anode Flex Connector 8/10/2024 8/10/2027
Corrosion Prot - Piping Fiberglass Non-Corrosive N/A N/A
Corrosion Prot - Tank Fiberglass Non-Corrosive N/A N/A
Leak Detect - Piping Mechanical Pressurized Line Leak Detection 7/2/2024 7/2/2025
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 350 Plus with CSLD 7/2/2024 7/2/2025
Overfill Prev Device Overfill Drop Tube Valve 2/9/2023 2/9/2026
Piping Fiberglass Single Wall Piping N/A N/A
Piping Not Installed STP/Tanktop Sump N/A N/A
Spill Contain Device Double Wall Spill Bucket 9/20/2022 9/20/2025
Tank Fiberglass Single Wall N/A N/A
Vent, Riser, Fill Piping Steel risers N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Fiberglass Single Wall Piping Precision Test (Piping) Pass 7/2/2024
Tank Fiberglass Single Wall Precision Test (Tank) Pass 7/6/2023



Tank Number 9

Capacity: 1000 Petroleum Use:
Product: Used Oil CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 8/16/1999 Abandoned Material:
Current Age: 25 Abandoned Date:
Install Date: 5/24/1999 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 6/1/1999

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Flexible Non-Corrosive N/A N/A
Corrosion Prot - Tank Fiberglass Non-Corrosive N/A N/A
Leak Detect - Piping Gravity Feed N/A N/A
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 350 Plus with CSLD 7/2/2024 7/2/2025
Leak Detect - Tank Non-Discriminating Interstitial Monitoring Sensors 7/2/2024 7/2/2025
Overfill Prev Device Less than 25 gallon fills N/A N/A
Piping Flexible Double Wall N/A N/A
Piping Single Wall STP/Tanktop Sump 9/20/2022 9/20/2025
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Installed N/A N/A
Spill Contain Device Single Wall Spill Bucket 4/25/2022 4/25/2025
Tank Fiberglass Double Wall N/A N/A
Vent, Riser, Fill Piping Steel risers N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Flexible Double Wall Precision Test (Piping) Pass 7/6/2023
Tank Fiberglass Double Wall Precision Test (Tank) Pass 7/6/2023
Leak Detect - Tank Non-Discriminating Interstitial Monitoring Sensors Sensor Functional Pass 5/24/2008



Tank Number 10

Capacity: 10000 Petroleum Use:
Product: Motor Oil CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 8/16/1999 Abandoned Material:
Current Age: 25 Abandoned Date:
Install Date: 5/24/1999 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 6/1/1999

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Fiberglass Non-Corrosive N/A N/A
Corrosion Prot - Tank Fiberglass Non-Corrosive N/A N/A
Leak Detect - Piping European with No Test Req Suction N/A N/A
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 350 Plus with CSLD 7/6/2023 7/2/2024
Leak Detect - Tank Non-Discriminating Interstitial Monitoring Sensors 7/2/2024 7/2/2025
Overfill Prev Device Overfill Drop Tube Valve 9/13/2022 9/13/2025
Piping Fiberglass Double Wall Ameron Dualoy 3000/LCX N/A N/A
Piping Fiberglass Double Wall N/A N/A
Piping Single Wall STP/Tanktop Sump
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Installed N/A N/A
Spill Contain Device Single Wall Spill Bucket 4/25/2022 4/25/2025
Tank Fiberglass Double Wall N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Fiberglass Double Wall Precision Test (Piping) Pass 7/6/2023
Piping Fiberglass Double Wall Ameron Dualoy 3000/LCX Precision Test (Piping) Pass 7/6/2023
Tank Fiberglass Double Wall Precision Test (Tank) Pass 7/6/2023



Tank Number 11

Capacity: 20000 Petroleum Use:
Product: B-99 CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 8/4/2022 Abandoned Material:
Current Age: 2 Abandoned Date:
Install Date: 3/29/2022 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 8/3/2022

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Fiberglass Non-Corrosive N/A N/A
Corrosion Prot - Tank Fiberglass Non-Corrosive N/A N/A
Leak Detect - Piping Mechanical Pressurized Line Leak Detection 7/6/2023 7/6/2024
Leak Detect - Piping Mechanical Pressurized Line Leak Detection 7/6/2023 7/6/2024
Leak Detect - Tank Non-Discriminating Interstitial Monitoring Sensors With Monitor 7/2/2024 7/2/2025
Overfill Prev Device Overfill Drop Tube Valve 9/13/2022 9/13/2025
Piping Blending Sump 4/28/2022 4/28/2025
Leak Detect - Piping Sump Sensor with positive shutdown 7/2/2024 7/2/2025
Piping Blending Sump 4/28/2022 4/28/2025
Leak Detect - Piping Sump Sensor with positive shutdown 7/2/2024 7/2/2025
Piping Fiberglass Double Wall Ameron Dualoy 3000/LCX N/A N/A
Piping Single Wall STP/Tanktop Sump 4/28/2022 4/28/2025
Leak Detect - Piping Sump Sensor with positive shutdown 7/2/2024 7/2/2025
Piping Single Wall STP/Tanktop Sump 4/28/2022 4/28/2025
Leak Detect - Piping Sump Sensor with positive shutdown 7/2/2024 7/2/2025
Spill Contain Device Double Wall Spill Bucket 4/28/2022 4/28/2025
Tank Fiberglass Double Wall Containment Solutions N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Blending Sump Precision Test (Piping) Pass 3/13/2025
Piping Blending Sump Precision Test (Piping) Pass 3/13/2025
Piping Fiberglass Double Wall Ameron Dualoy 3000/LCX Precision Test (Piping) Pass 3/13/2025
Tank Fiberglass Double Wall Containment Solutions Precision Test (Tank) Pass 7/6/2023

Dispenser Information



Name\ID 1 Diesel

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 7/6/2023 7/6/2026
Leak Detect - Piping Sump Sensor with positive shutdown 7/2/2024 7/2/2025



Name\ID 1/2

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 9/20/2022 9/20/2025
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Installed N/A N/A



Name\ID 1S/2 Diesel

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 7/6/2023 7/6/2026
Leak Detect - Piping Sump Sensor with positive shutdown 7/2/2024 7/2/2025



Name\ID 2S/3 Diesel

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 7/6/2023 7/6/2026
Leak Detect - Piping Sump Sensor with positive shutdown 7/2/2024 7/2/2025



Name\ID 3/4

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 9/20/2022 9/20/2025
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Installed N/A N/A



Name\ID 3S/4 Diesel

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 7/6/2023 7/6/2026
Leak Detect - Piping Sump Sensor with positive shutdown 7/2/2024 7/2/2025



Name\ID 4S/5 Diesel

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 7/6/2023 7/6/2026
Leak Detect - Piping Sump Sensor with positive shutdown 7/2/2024 7/2/2025



Name\ID 5/6

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Installed N/A N/A



Name\ID 5S/6 Diesel

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 7/6/2023 7/6/2026
Leak Detect - Piping Sump Sensor with positive shutdown 7/2/2024 7/2/2025



Name\ID 6S/7 Diesel

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 7/6/2023 7/6/2026
Leak Detect - Piping Sump Sensor with positive shutdown 7/2/2024 7/2/2025



Name\ID 7/8

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Installed N/A N/A



Name\ID 7S/8 Diesel

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 7/6/2023 7/6/2026
Leak Detect - Piping Sump Sensor with positive shutdown 7/2/2024 7/2/2025



Name\ID 8S Diesel

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 7/6/2023 7/6/2026
Leak Detect - Piping Sump Sensor with positive shutdown 7/2/2024 7/2/2025

MFD Motorfuel Dispensing Forms