Owner Summary
Click for Facility/Tank Ownership history
| Owner Number |
Owner Name |
Owner Status |
Purchase Date |
| U0036467 |
Aving-Rice, LLC |
Current Owner |
2/23/2012 |
| U0033394 |
SNC JJ Olney II, LLC |
Former Owner |
4/10/2006 |
| U0025512 |
DO NOT USE |
Former Owner |
4/12/1997 |
| U0011931 |
Ronald Tompkins d/b/a Pioneer Oil Company |
Former Owner |
12/31/1967 |
| U0017339 |
Niebrugge Oil Company |
Former Owner |
|
Notice of Violations (Current)
No Notice of Violations Found
IEMA Numbers Associated with the Facility
| IEMA Number |
Inspection Date |
Inspection Type |
Permit Number |
| 15-0331 |
3/31/2015 |
Removal Log |
01001-2014REM |
LUST
Fund Eligibility and Deductibility Determinations
| IEMA Number |
Status |
OSFM Received Date |
OSFM Response Date |
Deductible |
Letter |
| 07-1031 |
Eligible |
9/20/2007
|
9/25/2007
|
$10,000
|
|
| 07-1031 |
Eligible |
6/11/2012
|
8/3/2012
|
$10,000
|
|
Tank Number 1
| Capacity: |
10000 |
|
Petroleum Use: |
|
| Product: |
Gasoline |
|
CERCLA Substance: |
|
| Status: |
Removed |
|
CAS Code: |
|
| Regulated Status: |
Federal |
|
Removed Date: |
3/31/2015 |
|
OSFM
First Notify Date: |
4/23/1986 |
|
Abandoned Material: |
|
| Current Age: |
48 |
|
Abandoned Date: |
|
| Install Date: |
1/1/1967 |
|
Red Tag Issue Date: |
|
| Last Used Date: |
7/10/2012 |
|
Fee Due: |
$0.00 |
| Product Date: |
|
|
|
|
Equipment Information
| Equipment Type |
Equipment |
Last Passing Date |
Test Expire Date |
|
Corrosion Prot - Piping
|
Sacrificial Anode Cathodic Protection |
7/31/2009 |
7/31/2012 |
|
Corrosion Prot - Piping
|
Fiberglass Non-Corrosive |
Not applicable |
Not applicable |
|
Corrosion Prot - Tank
|
Lining Materials Internal |
6/26/2007 |
6/26/2012 |
|
Leak Detect - Piping
|
Mechanical Pressurized Line Leak Detection |
5/17/2011 |
5/17/2012 |
|
Leak Detect - Tank
|
Automatic Tank Gauging Red Jacket Pro Plus |
No passing test found |
No passing test found |
|
Overfill Prev Device
|
Ball Float Vent Valve |
No passing test found |
No passing test found |
|
Piping
|
Fiberglass Single Wall Piping |
Not applicable |
Not applicable |
|
Spill Contain Device
|
Single Wall Spill Bucket |
No passing test found |
No passing test found |
|
Tank
|
Steel Single Wall |
Not applicable |
Not applicable |
|
Vent, Riser, Fill Piping
|
Steel risers |
Not applicable |
Not applicable |
Additional Tests
No Tests Listed
Tank Number 2
| Capacity: |
10000 |
|
Petroleum Use: |
|
| Product: |
Diesel Fuel |
|
CERCLA Substance: |
|
| Status: |
Removed |
|
CAS Code: |
|
| Regulated Status: |
Federal |
|
Removed Date: |
3/31/2015 |
|
OSFM
First Notify Date: |
4/23/1986 |
|
Abandoned Material: |
|
| Current Age: |
48 |
|
Abandoned Date: |
|
| Install Date: |
1/1/1967 |
|
Red Tag Issue Date: |
|
| Last Used Date: |
7/11/2012 |
|
Fee Due: |
$0.00 |
| Product Date: |
|
|
|
|
Equipment Information
| Equipment Type |
Equipment |
Last Passing Date |
Test Expire Date |
|
Corrosion Prot - Piping
|
Sacrificial Anode Cathodic Protection |
7/31/2009 |
7/31/2012 |
|
Corrosion Prot - Piping
|
Fiberglass Non-Corrosive |
Not applicable |
Not applicable |
|
Corrosion Prot - Tank
|
Lining Materials Internal |
6/26/2007 |
6/26/2012 |
|
Leak Detect - Piping
|
Mechanical Pressurized Line Leak Detection |
5/17/2011 |
5/17/2012 |
|
Leak Detect - Tank
|
Automatic Tank Gauging Red Jacket Pro Plus |
No passing test found |
No passing test found |
|
Overfill Prev Device
|
Ball Float Vent Valve |
No passing test found |
No passing test found |
|
Piping
|
Fiberglass Single Wall Piping |
Not applicable |
Not applicable |
|
Spill Contain Device
|
Single Wall Spill Bucket |
No passing test found |
No passing test found |
|
Tank
|
Steel Single Wall |
Not applicable |
Not applicable |
|
Vent, Riser, Fill Piping
|
Steel risers |
Not applicable |
Not applicable |
Additional Tests
No Tests Listed
Tank Number 3
| Capacity: |
4000 |
|
Petroleum Use: |
|
| Product: |
Gasoline |
|
CERCLA Substance: |
|
| Status: |
Removed |
|
CAS Code: |
|
| Regulated Status: |
Federal |
|
Removed Date: |
3/31/2015 |
|
OSFM
First Notify Date: |
4/23/1986 |
|
Abandoned Material: |
Inert material mixed with portland cement |
| Current Age: |
41 |
|
Abandoned Date: |
9/20/2007 |
| Install Date: |
1/1/1974 |
|
Red Tag Issue Date: |
|
| Last Used Date: |
9/27/2007 |
|
Fee Due: |
$0.00 |
| Product Date: |
|
|
|
|
Equipment Information
| Equipment Type |
Equipment |
Last Passing Date |
Test Expire Date |
|
Corrosion Prot - Piping
|
Fiberglass Non-Corrosive |
Not applicable |
Not applicable |
|
Corrosion Prot - Tank
|
Lining Materials Internal |
No passing test found |
No passing test found |
|
Leak Detect - Piping
|
Pressurized Line Leak Detection |
No passing test found |
No passing test found |
|
Leak Detect - Tank
|
Automatic Tank Gauging Veeder Root TLS 300i |
No passing test found |
No passing test found |
|
Overfill Prev Device
|
Ball Float Vent Valve |
No passing test found |
No passing test found |
|
Piping
|
Fiberglass Single Wall Piping |
Not applicable |
Not applicable |
|
Spill Contain Device
|
Manhole Field Constructed |
No passing test found |
No passing test found |
|
Tank
|
Steel Single Wall |
Not applicable |
Not applicable |
Additional Tests
No Tests Listed
Tank Number 4
| Capacity: |
550 |
|
Petroleum Use: |
|
| Product: |
Used Oil |
|
CERCLA Substance: |
|
| Status: |
Removed |
|
CAS Code: |
|
| Regulated Status: |
Federal |
|
Removed Date: |
11/23/1998 |
|
OSFM
First Notify Date: |
4/23/1986 |
|
Abandoned Material: |
|
| Current Age: |
31 |
|
Abandoned Date: |
|
| Install Date: |
1/1/1967 |
|
Red Tag Issue Date: |
|
| Last Used Date: |
|
|
Fee Due: |
$0.00 |
| Product Date: |
|
|
|
|
Equipment Information
No Equipment Listed
Additional Tests
No Tests Listed
Tank Number 5
| Capacity: |
1000 |
|
Petroleum Use: |
Consumptive Use on Premises for Heating |
| Product: |
Heating Oil |
|
CERCLA Substance: |
|
| Status: |
Removed |
|
CAS Code: |
|
| Regulated Status: |
State |
|
Removed Date: |
11/23/1998 |
|
OSFM
First Notify Date: |
4/23/1986 |
|
Abandoned Material: |
|
| Current Age: |
31 |
|
Abandoned Date: |
|
| Install Date: |
1/1/1967 |
|
Red Tag Issue Date: |
|
| Last Used Date: |
|
|
Fee Due: |
$0.00 |
| Product Date: |
|
|
|
|
Equipment Information
No Equipment Listed
Additional Tests
No Tests Listed
Failed test = the latest test has failed.
Not applicable = a test does not apply to this equipment type or configuration.
No passing test found = a passing test is expected but was not found from the source data.
Dispenser Information
Failed test = the latest test has failed.
Not applicable = a test does not apply to this equipment type or configuration.
No passing test found = a passing test is expected but was not found from the source data.
MFD
Motorfuel Dispensing Forms
No Forms Found