Owner Summary
Click for Facility/Tank Ownership history
| Owner Number |
Owner Name |
Owner Status |
Purchase Date |
| U0038334 |
Acees, Inc. |
Current Owner |
|
| U0030760 |
Golightly & Long, LLC |
Former Owner |
5/1/2002 |
| U0022089 |
Duke & Long Distributing Co., Inc. |
Former Owner |
1/1/1995 |
| U0021551 |
Metropolis Truck Travel Plaza |
Former Owner |
5/10/1993 |
| U0012419 |
Ralph Powells Truck Plaza |
Former Owner |
12/31/1967 |
| U0036576 |
Cheers Food & Fuel, Inc. |
Former Owner |
|
| U0014099 |
Smoot Oil Company, Inc. |
Former Owner |
|
Notice of Violations (Current)
No Notice of Violations Found
IEMA Numbers Associated with the Facility
| IEMA Number |
Inspection Date |
Inspection Type |
Permit Number |
| 06-0121 |
2/1/2006 |
Removal Log |
00060-2006REM |
LUST
Fund Eligibility and Deductibility Determinations
| IEMA Number |
Status |
OSFM Received Date |
OSFM Response Date |
Deductible |
Letter |
| 05-1562 |
Eligible |
12/12/2005
|
1/27/2006
|
$10,000
|
|
Tank Number 1
| Capacity: |
10000 |
|
Petroleum Use: |
|
| Product: |
Gasoline |
|
CERCLA Substance: |
|
| Status: |
Removed |
|
CAS Code: |
|
| Regulated Status: |
Federal |
|
Removed Date: |
2/1/2006 |
|
OSFM
First Notify Date: |
3/21/1986 |
|
Abandoned Material: |
|
| Current Age: |
24 |
|
Abandoned Date: |
|
| Install Date: |
1/1/1982 |
|
Red Tag Issue Date: |
|
| Last Used Date: |
|
|
Fee Due: |
$0.00 |
| Product Date: |
|
|
|
|
Equipment Information
No Equipment Listed
Additional Tests
No Tests Listed
Tank Number 2
| Capacity: |
10000 |
|
Petroleum Use: |
|
| Product: |
Gasoline |
|
CERCLA Substance: |
|
| Status: |
Removed |
|
CAS Code: |
|
| Regulated Status: |
Federal |
|
Removed Date: |
2/1/2006 |
|
OSFM
First Notify Date: |
3/21/1986 |
|
Abandoned Material: |
|
| Current Age: |
24 |
|
Abandoned Date: |
|
| Install Date: |
1/1/1982 |
|
Red Tag Issue Date: |
|
| Last Used Date: |
|
|
Fee Due: |
$0.00 |
| Product Date: |
|
|
|
|
Equipment Information
No Equipment Listed
Additional Tests
No Tests Listed
Tank Number 3
| Capacity: |
10000 |
|
Petroleum Use: |
|
| Product: |
Gasoline |
|
CERCLA Substance: |
|
| Status: |
Removed |
|
CAS Code: |
|
| Regulated Status: |
Federal |
|
Removed Date: |
2/1/2006 |
|
OSFM
First Notify Date: |
3/21/1986 |
|
Abandoned Material: |
|
| Current Age: |
24 |
|
Abandoned Date: |
|
| Install Date: |
1/1/1982 |
|
Red Tag Issue Date: |
|
| Last Used Date: |
|
|
Fee Due: |
$0.00 |
| Product Date: |
|
|
|
|
Equipment Information
No Equipment Listed
Additional Tests
No Tests Listed
Tank Number 4
| Capacity: |
10000 |
|
Petroleum Use: |
|
| Product: |
Diesel Fuel |
|
CERCLA Substance: |
|
| Status: |
Removed |
|
CAS Code: |
|
| Regulated Status: |
Federal |
|
Removed Date: |
2/1/2006 |
|
OSFM
First Notify Date: |
3/21/1986 |
|
Abandoned Material: |
Inert material mixed with portland cement |
| Current Age: |
24 |
|
Abandoned Date: |
4/28/2000 |
| Install Date: |
1/1/1982 |
|
Red Tag Issue Date: |
|
| Last Used Date: |
12/22/1998 |
|
Fee Due: |
$0.00 |
| Product Date: |
|
|
|
|
Equipment Information
No Equipment Listed
Additional Tests
No Tests Listed
Tank Number 5
| Capacity: |
10000 |
|
Petroleum Use: |
|
| Product: |
Diesel Fuel |
|
CERCLA Substance: |
|
| Status: |
Removed |
|
CAS Code: |
|
| Regulated Status: |
Federal |
|
Removed Date: |
2/1/2006 |
|
OSFM
First Notify Date: |
3/21/1986 |
|
Abandoned Material: |
|
| Current Age: |
24 |
|
Abandoned Date: |
|
| Install Date: |
1/1/1982 |
|
Red Tag Issue Date: |
|
| Last Used Date: |
|
|
Fee Due: |
$0.00 |
| Product Date: |
|
|
|
|
Equipment Information
No Equipment Listed
Additional Tests
No Tests Listed
Tank Number 6
| Capacity: |
10000 |
|
Petroleum Use: |
|
| Product: |
Diesel Fuel |
|
CERCLA Substance: |
|
| Status: |
Removed |
|
CAS Code: |
|
| Regulated Status: |
Federal |
|
Removed Date: |
2/1/2006 |
|
OSFM
First Notify Date: |
3/21/1986 |
|
Abandoned Material: |
|
| Current Age: |
24 |
|
Abandoned Date: |
|
| Install Date: |
1/1/1982 |
|
Red Tag Issue Date: |
|
| Last Used Date: |
|
|
Fee Due: |
$0.00 |
| Product Date: |
1/1/1982 |
|
|
|
Equipment Information
No Equipment Listed
Additional Tests
No Tests Listed
Tank Number 7
| Capacity: |
10000 |
|
Petroleum Use: |
|
| Product: |
Diesel Fuel |
|
CERCLA Substance: |
|
| Status: |
Removed |
|
CAS Code: |
|
| Regulated Status: |
Federal |
|
Removed Date: |
2/1/2006 |
|
OSFM
First Notify Date: |
3/21/1986 |
|
Abandoned Material: |
Inert material mixed with portland cement |
| Current Age: |
24 |
|
Abandoned Date: |
4/28/2000 |
| Install Date: |
1/1/1982 |
|
Red Tag Issue Date: |
|
| Last Used Date: |
12/28/1998 |
|
Fee Due: |
$0.00 |
| Product Date: |
1/1/1982 |
|
|
|
Equipment Information
No Equipment Listed
Additional Tests
No Tests Listed
Tank Number 8
| Capacity: |
20000 |
|
Petroleum Use: |
|
| Product: |
Gasoline |
|
CERCLA Substance: |
|
| Status: |
Removed |
|
CAS Code: |
|
| Regulated Status: |
Federal |
|
Removed Date: |
2/6/2006 |
|
OSFM
First Notify Date: |
3/21/2006 |
|
Abandoned Material: |
|
| Current Age: |
0 |
|
Abandoned Date: |
|
| Install Date: |
1/25/2006 |
|
Red Tag Issue Date: |
|
| Last Used Date: |
|
|
Fee Due: |
$0.00 |
| Product Date: |
1/25/2006 |
|
|
|
Equipment Information
| Equipment Type |
Equipment |
Last Passing Date |
Test Expire Date |
|
Corrosion Prot - Piping
|
Flexible Non-Corrosive |
Not applicable |
Not applicable |
|
Corrosion Prot - Tank
|
Composite Non-Corrosive |
Not applicable |
Not applicable |
|
Leak Detect - Piping
|
Electronic Pressurized Line Leak Detection |
No passing test found |
No passing test found |
|
Leak Detect - Tank
|
Automatic Tank Gauging Veeder Root TLS 350R |
No passing test found |
No passing test found |
|
Overfill Prev Device
|
Overfill Drop Tube Valve |
No passing test found |
No passing test found |
|
Piping
|
Flexible Double Wall A.P.T. Poly Tech P150SC |
Not applicable |
Not applicable |
|
Spill Contain Device
|
Single Wall Spill Bucket |
No passing test found |
No passing test found |
|
Tank
|
Composite Single Wall ACT 100 |
Not applicable |
Not applicable |
Additional Tests
No Tests Listed
Tank Number 9
| Capacity: |
5000 |
|
Petroleum Use: |
|
| Product: |
Gasoline |
|
CERCLA Substance: |
|
| Status: |
Removed |
|
CAS Code: |
|
| Regulated Status: |
Federal |
|
Removed Date: |
2/6/2006 |
|
OSFM
First Notify Date: |
3/21/2006 |
|
Abandoned Material: |
|
| Current Age: |
0 |
|
Abandoned Date: |
|
| Install Date: |
1/25/2006 |
|
Red Tag Issue Date: |
|
| Last Used Date: |
|
|
Fee Due: |
$0.00 |
| Product Date: |
1/25/2006 |
|
|
|
Equipment Information
| Equipment Type |
Equipment |
Last Passing Date |
Test Expire Date |
|
Corrosion Prot - Piping
|
Flexible Non-Corrosive |
Not applicable |
Not applicable |
|
Corrosion Prot - Tank
|
Composite Non-Corrosive |
Not applicable |
Not applicable |
|
Leak Detect - Piping
|
Electronic Pressurized Line Leak Detection |
No passing test found |
No passing test found |
|
Leak Detect - Tank
|
Automatic Tank Gauging Veeder Root TLS 350R |
No passing test found |
No passing test found |
|
Overfill Prev Device
|
Overfill Drop Tube Valve |
No passing test found |
No passing test found |
|
Piping
|
Flexible Double Wall A.P.T. Poly Tech P150SC |
Not applicable |
Not applicable |
|
Spill Contain Device
|
Single Wall Spill Bucket |
No passing test found |
No passing test found |
|
Tank
|
Composite Single Wall ACT 100 |
Not applicable |
Not applicable |
Additional Tests
No Tests Listed
Tank Number 10
| Capacity: |
15000 |
|
Petroleum Use: |
|
| Product: |
Diesel Fuel |
|
CERCLA Substance: |
|
| Status: |
Removed |
|
CAS Code: |
|
| Regulated Status: |
Federal |
|
Removed Date: |
2/6/2006 |
|
OSFM
First Notify Date: |
3/21/2006 |
|
Abandoned Material: |
|
| Current Age: |
0 |
|
Abandoned Date: |
|
| Install Date: |
1/25/2006 |
|
Red Tag Issue Date: |
|
| Last Used Date: |
|
|
Fee Due: |
$0.00 |
| Product Date: |
1/25/2006 |
|
|
|
Equipment Information
| Equipment Type |
Equipment |
Last Passing Date |
Test Expire Date |
|
Corrosion Prot - Piping
|
Flexible Non-Corrosive |
Not applicable |
Not applicable |
|
Corrosion Prot - Tank
|
Composite Non-Corrosive |
Not applicable |
Not applicable |
|
Leak Detect - Piping
|
Electronic Pressurized Line Leak Detection |
No passing test found |
No passing test found |
|
Leak Detect - Tank
|
Automatic Tank Gauging Veeder Root TLS 350R |
No passing test found |
No passing test found |
|
Overfill Prev Device
|
Overfill Drop Tube Valve |
No passing test found |
No passing test found |
|
Piping
|
Flexible Double Wall A.P.T. Poly Tech P150SC |
Not applicable |
Not applicable |
|
Spill Contain Device
|
Single Wall Spill Bucket |
No passing test found |
No passing test found |
|
Tank
|
Composite Single Wall ACT 100 |
Not applicable |
Not applicable |
Additional Tests
No Tests Listed
Tank Number 11
| Capacity: |
20000 |
|
Petroleum Use: |
|
| Product: |
Gasoline - Regular |
|
CERCLA Substance: |
|
| Status: |
Currently in use |
|
CAS Code: |
|
| Regulated Status: |
Federal |
|
Removed Date: |
|
|
OSFM
First Notify Date: |
3/21/2006 |
|
Abandoned Material: |
|
| Current Age: |
20 |
|
Abandoned Date: |
|
| Install Date: |
3/17/2006 |
|
Red Tag Issue Date: |
|
| Last Used Date: |
|
|
Fee Due: |
$0.00 |
| Product Date: |
3/17/2006 |
|
|
|
Equipment Information
| Equipment Type |
Equipment |
Last Passing Date |
Test Expire Date |
|
Corrosion Prot - Piping
|
Flexible Non-Corrosive |
Not applicable |
Not applicable |
|
Corrosion Prot - Tank
|
Composite Non-Corrosive |
Not applicable |
Not applicable |
|
Leak Detect - Piping
|
Electronic Pressurized Line Leak Detection |
7/20/2026 |
7/20/2027 |
|
Leak Detect - Tank
|
Automatic Tank Gauging Veeder Root TLS 350R |
7/14/2026 |
7/14/2027 |
|
Overfill Prev Device
|
Overfill Drop Tube Valve |
10/3/2024 |
10/3/2027 |
|
Piping
|
Flexible Double Wall A.P.T. Poly Tech P150SC |
Not applicable |
Not applicable |
|
Piping
|
Single Wall STP/Tanktop Sump |
10/3/2024 |
10/3/2027 |
Leak Detect - Piping
|
Sump Sensor with positive shutdown |
10/3/2024 |
10/3/2027 |
|
Piping
|
Single Wall STP/Tanktop Sump |
10/3/2024 |
10/3/2027 |
Leak Detect - Piping
|
Sump Sensor with positive shutdown |
10/3/2024 |
10/3/2027 |
|
Spill Contain Device
|
Single Wall Spill Bucket |
10/3/2024 |
10/3/2027 |
|
Tank
|
Composite Single Wall ACT 100 |
Not applicable |
Not applicable |
Additional Tests
| Equipment Type |
Equipment |
Test Type |
Test Result |
Test Date |
|
Piping
|
Flexible Double Wall A.P.T. Poly Tech P150SC
|
Precision Test (Piping)
|
Pass
|
3/3/2022
|
Tank Number 12
| Capacity: |
5000 |
|
Petroleum Use: |
|
| Product: |
Gasoline - Premium |
|
CERCLA Substance: |
|
| Status: |
Currently in use |
|
CAS Code: |
|
| Regulated Status: |
Federal |
|
Removed Date: |
|
|
OSFM
First Notify Date: |
3/21/2006 |
|
Abandoned Material: |
|
| Current Age: |
20 |
|
Abandoned Date: |
|
| Install Date: |
3/17/2006 |
|
Red Tag Issue Date: |
|
| Last Used Date: |
|
|
Fee Due: |
$0.00 |
| Product Date: |
3/17/2006 |
|
|
|
Equipment Information
| Equipment Type |
Equipment |
Last Passing Date |
Test Expire Date |
|
Corrosion Prot - Piping
|
Flexible Non-Corrosive |
Not applicable |
Not applicable |
|
Corrosion Prot - Tank
|
Composite Non-Corrosive |
Not applicable |
Not applicable |
|
Leak Detect - Piping
|
Electronic Pressurized Line Leak Detection |
7/14/2026 |
7/14/2027 |
|
Leak Detect - Tank
|
Automatic Tank Gauging Veeder Root TLS 350R |
7/14/2026 |
7/14/2027 |
|
Overfill Prev Device
|
Overfill Drop Tube Valve |
10/3/2024 |
10/3/2027 |
|
Piping
|
Flexible Double Wall A.P.T. Poly Tech P150SC |
Not applicable |
Not applicable |
|
Piping
|
Single Wall STP/Tanktop Sump |
10/3/2024 |
10/3/2027 |
Leak Detect - Piping
|
Sump Sensor with positive shutdown |
10/3/2024 |
10/3/2027 |
|
Spill Contain Device
|
Single Wall Spill Bucket |
10/3/2024 |
10/3/2027 |
|
Tank
|
Composite Single Wall ACT 100 |
Not applicable |
Not applicable |
Additional Tests
No Tests Listed
Tank Number 13
| Capacity: |
15000 |
|
Petroleum Use: |
|
| Product: |
Diesel Fuel |
|
CERCLA Substance: |
|
| Status: |
Currently in use |
|
CAS Code: |
|
| Regulated Status: |
Federal |
|
Removed Date: |
|
|
OSFM
First Notify Date: |
3/21/2006 |
|
Abandoned Material: |
|
| Current Age: |
20 |
|
Abandoned Date: |
|
| Install Date: |
3/17/2006 |
|
Red Tag Issue Date: |
|
| Last Used Date: |
|
|
Fee Due: |
$0.00 |
| Product Date: |
3/17/2006 |
|
|
|
Equipment Information
| Equipment Type |
Equipment |
Last Passing Date |
Test Expire Date |
|
Corrosion Prot - Piping
|
Flexible Non-Corrosive |
Not applicable |
Not applicable |
|
Corrosion Prot - Tank
|
Composite Non-Corrosive |
Not applicable |
Not applicable |
|
Leak Detect - Piping
|
Electronic Pressurized Line Leak Detection |
7/14/2026 |
7/14/2027 |
|
Leak Detect - Tank
|
Automatic Tank Gauging Veeder Root TLS 350R |
7/14/2026 |
7/14/2027 |
|
Overfill Prev Device
|
Overfill Drop Tube Valve |
10/3/2024 |
10/3/2027 |
|
Piping
|
Flexible Double Wall A.P.T. Poly Tech P150SC |
Not applicable |
Not applicable |
|
Piping
|
Single Wall STP/Tanktop Sump |
10/3/2024 |
10/3/2027 |
Leak Detect - Piping
|
Sump Sensor with positive shutdown |
10/3/2024 |
10/3/2027 |
|
Spill Contain Device
|
Single Wall Spill Bucket |
10/3/2024 |
10/3/2027 |
|
Tank
|
Composite Single Wall ACT 100 |
Not applicable |
Not applicable |
Additional Tests
No Tests Listed
Failed test = the latest test has failed.
Not applicable = a test does not apply to this equipment type or configuration.
No passing test found = a passing test is expected but was not found from the source data.
MFD
Motorfuel Dispensing Forms
No Forms Found