Facility Details
Facility Number:
7001633
Status:
Active
Facility Name:
Fast Stop Thomas Liquor & Gas
Address:
527 East Vine Vienna, IL 62995
County:
Johnson
Property Parcel:
08-04-401-021
Facility Type:
Attended Self-Service Station
Owner Type:
Private
Green Tag Decal:
AA00666
Green Tag Issue Date:
9/5/2025
Green Tag Expiration Date:
12/31/2027
Owner Details
Owner Name:
Jeff Mathis and Linda Mathis
Owner Address:
527 East Vine Vienna, IL 62995
Owner Status:
Current Owner
Purchase Date:
8/27/1985
Type of Financial Responsibility:
Designated Savings Account
Financial Responsibility Reporting Due Date:
9/5/2026
Motor Fuel Dispensing Permits
MFD Permit Type
Issue Date
Expiration Date
Self Service
9/5/2025
12/31/2027
Owner Summary
Click for Facility/Tank Ownership history
Owner Number
Owner Name
Owner Status
Purchase Date
U0041594
Jeff Mathis and Linda Mathis
Current Owner
8/27/1985
U0034044
Alchemist USA, LLC
Former Owner
4/1/1999
U0015667
Veach Oil Company
Former Owner
1/22/1987
Permits (Unexpired)
Click for permit history
Permit Number
Type
Status
OSFM Receive Date
Issue Date
Expiration Date
Documents
01118-2025CAT
Cathodic Protection
Approved / Issued
8/26/2025
8/26/2025
2/26/2026
Documents
Notice of Violatlions (Current)
No Notice of Violations Found
IEMA Numbers Associated with the Facility
No IEMA Numbers Found
LUST
Fund Eligibility and Deductibility Determinations
No Applications Found
Pay Tank Fees Online
Tank Information
Tank Number 1
Capacity:
8000
Petroleum Use:
Product:
Gasoline - Regular
CERCLA Substance:
Status:
Currently in use
CAS Code:
Regulated Status:
Federal
Removed Date:
OSFM
First Notify Date:
3/4/1988
Abandoned Material:
Current Age:
38
Abandoned Date:
Install Date:
1/22/1987
Red Tag Issue Date:
Last Used Date:
Fee Due:
$0.00
Product Date:
1/22/1987
Equipment
Equipment Type
Equipment
Last Passing Date
Test Expire Date
Corrosion Prot - Piping
Sacrificial Anode Cathodic Protection
9/4/2025
9/4/2028
Corrosion Prot - Piping
Flexible Non-Corrosive
N/A
N/A
Corrosion Prot - Tank
STIP3 Cathodic Protection with Dielectric Coating
5/1/2023
5/1/2026
Leak Detect - Piping
Electronic Pressurized Line Leak Detection
5/5/2025
5/5/2026
Leak Detect - Tank
Automatic Tank Gauging Veeder Root TLS 350
5/5/2025
5/5/2026
Overfill Prev Device
Overfill Drop Tube Valve
5/1/2023
5/1/2026
Piping
Flexible Double Wall
N/A
N/A
Piping
Single Wall STP/Tanktop Sump
Leak Detect - Piping
Piping Sump Sensors Not Regulated Not Required
N/A
N/A
Spill Contain Device
Single Wall Spill Bucket
5/1/2023
5/1/2026
Tank
STIP3 Single Wall
N/A
N/A
Additional Tests
Equipment Type
Equipment
Test Type
Test Result
Test Date
Piping
Fiberglass Single Wall Piping
Precision Test (Piping)
Pass
5/5/2025
Tank Number 2
Capacity:
8000
Petroleum Use:
None
Product:
Diesel Fuel
CERCLA Substance:
Status:
Currently in use
CAS Code:
Regulated Status:
Federal
Removed Date:
OSFM
First Notify Date:
3/4/1988
Abandoned Material:
Current Age:
38
Abandoned Date:
Install Date:
1/22/1987
Red Tag Issue Date:
Last Used Date:
Fee Due:
$0.00
Product Date:
1/22/1987
Equipment
Equipment Type
Equipment
Last Passing Date
Test Expire Date
Corrosion Prot - Piping
Sacrificial Anode Cathodic Protection
9/4/2025
9/4/2028
Corrosion Prot - Piping
Flexible Non-Corrosive
N/A
N/A
Corrosion Prot - Tank
STIP3 Cathodic Protection with Dielectric Coating
5/1/2023
5/1/2026
Leak Detect - Piping
Electronic Pressurized Line Leak Detection
5/5/2025
5/5/2026
Leak Detect - Tank
Automatic Tank Gauging Veeder Root TLS 350
5/5/2025
5/5/2026
Overfill Prev Device
Overfill Drop Tube Valve
5/1/2023
5/1/2026
Piping
Flexible Double Wall
N/A
N/A
Piping
Single Wall STP/Tanktop Sump
Leak Detect - Piping
Piping Sump Sensors Not Regulated Not Required
N/A
N/A
Spill Contain Device
Single Wall Spill Bucket
5/1/2023
5/1/2026
Tank
STIP3 Single Wall
N/A
N/A
Additional Tests
Equipment Type
Equipment
Test Type
Test Result
Test Date
Piping
Fiberglass Single Wall Piping
Precision Test (Piping)
Pass
5/5/2025
Dispenser Information
Name\ID 1/2
Status:
Active
Equipment Type
Equipment
Last Passing Date
Test Expire Date
Dispenser
Single Wall UDC Sump
Leak Detect - Piping
Piping Sump Sensors Not Regulated Not Required
N/A
N/A
Name\ID 3/4
Status:
Active
Equipment Type
Equipment
Last Passing Date
Test Expire Date
Dispenser
Single Wall UDC Sump
Leak Detect - Piping
Piping Sump Sensors Not Regulated Not Required
N/A
N/A
MFD
Motorfuel Dispensing Forms
No Forms Found