Owner Summary
Click for Facility/Tank Ownership history
| Owner Number |
Owner Name |
Owner Status |
Purchase Date |
| U0038688 |
Shiv Tora, LLC |
Current Owner |
11/27/2004 |
| U0032581 |
Shivam Murphysboro, Inc. |
Former Owner |
11/27/2004 |
| U0006126 |
Green Oil Company |
Former Owner |
10/17/1988 |
| U0021101 |
Kerr Mcgee Refining Corp |
Former Owner |
12/31/1967 |
Notice of Violations (Current)
No Notice of Violations Found
IEMA Numbers Associated with the Facility
| IEMA Number |
Inspection Date |
Inspection Type |
Permit Number |
| 17-0148 |
3/23/2017 |
Removal Log |
00229-2017REM |
LUST
Fund Eligibility and Deductibility Determinations
| IEMA Number |
Status |
OSFM Received Date |
OSFM Response Date |
Deductible |
Letter |
| 20170148 |
Eligible |
4/13/2017
|
4/14/2017
|
$5,000
|
Letter
|
| 20170148 |
Eligible |
8/1/2019
|
8/1/2019
|
$5,000
|
Letter
|
Tank Number 1
| Capacity: |
6000 |
|
Petroleum Use: |
|
| Product: |
Gasoline |
|
CERCLA Substance: |
|
| Status: |
Removed |
|
CAS Code: |
|
| Regulated Status: |
Federal |
|
Removed Date: |
3/23/2017 |
|
OSFM
First Notify Date: |
3/3/1986 |
|
Abandoned Material: |
|
| Current Age: |
38 |
|
Abandoned Date: |
|
| Install Date: |
6/1/1978 |
|
Red Tag Issue Date: |
|
| Last Used Date: |
10/1/2014 |
|
Fee Due: |
$0.00 |
| Product Date: |
6/1/1978 |
|
|
|
Equipment Information
| Equipment Type |
Equipment |
Last Passing Date |
Test Expire Date |
|
Corrosion Prot - Piping
|
Impressed Current Cathodic Protection |
8/6/2012 |
8/6/2013 |
|
Corrosion Prot - Tank
|
Impressed Current Cathodic Protection |
8/6/2012 |
8/6/2013 |
|
Corrosion Prot - Tank
|
Lining Materials Internal |
10/5/2010 |
10/5/2015 |
|
Leak Detect - Piping
|
Mechanical Pressurized Line Leak Detection |
9/12/2012 |
9/12/2013 |
|
Leak Detect - Tank
|
Automatic Tank Gauging Veeder Root TLS 350j with CSLD |
No passing test found |
No passing test found |
|
Overfill Prev Device
|
Overfill Drop Tube Valve |
No passing test found |
No passing test found |
|
Piping
|
Steel Single Wall Piping |
Not applicable |
Not applicable |
|
Spill Contain Device
|
Single Wall Spill Bucket |
No passing test found |
No passing test found |
|
Tank
|
Steel Single Wall |
Not applicable |
Not applicable |
Additional Tests
No Tests Listed
Tank Number 2
| Capacity: |
4000 |
|
Petroleum Use: |
|
| Product: |
Gasoline |
|
CERCLA Substance: |
|
| Status: |
Removed |
|
CAS Code: |
|
| Regulated Status: |
Federal |
|
Removed Date: |
3/23/2017 |
|
OSFM
First Notify Date: |
3/3/1986 |
|
Abandoned Material: |
|
| Current Age: |
38 |
|
Abandoned Date: |
|
| Install Date: |
6/1/1978 |
|
Red Tag Issue Date: |
|
| Last Used Date: |
10/1/2014 |
|
Fee Due: |
$0.00 |
| Product Date: |
6/1/1978 |
|
|
|
Equipment Information
| Equipment Type |
Equipment |
Last Passing Date |
Test Expire Date |
|
Corrosion Prot - Piping
|
Impressed Current Cathodic Protection |
8/6/2012 |
8/6/2013 |
|
Corrosion Prot - Tank
|
Impressed Current Cathodic Protection |
8/6/2012 |
8/6/2013 |
|
Corrosion Prot - Tank
|
Lining Materials Internal |
10/5/2010 |
10/5/2015 |
|
Leak Detect - Piping
|
Mechanical Pressurized Line Leak Detection |
9/12/2012 |
9/12/2013 |
|
Leak Detect - Tank
|
Automatic Tank Gauging Veeder Root TLS 350j with CSLD |
No passing test found |
No passing test found |
|
Overfill Prev Device
|
Overfill Drop Tube Valve |
No passing test found |
No passing test found |
|
Piping
|
Steel Single Wall Piping |
Not applicable |
Not applicable |
|
Spill Contain Device
|
Single Wall Spill Bucket |
No passing test found |
No passing test found |
|
Tank
|
Steel Single Wall |
Not applicable |
Not applicable |
Additional Tests
No Tests Listed
Tank Number 3
| Capacity: |
4000 |
|
Petroleum Use: |
|
| Product: |
Gasoline |
|
CERCLA Substance: |
|
| Status: |
Removed |
|
CAS Code: |
|
| Regulated Status: |
Federal |
|
Removed Date: |
3/23/2017 |
|
OSFM
First Notify Date: |
3/3/1986 |
|
Abandoned Material: |
|
| Current Age: |
38 |
|
Abandoned Date: |
|
| Install Date: |
6/1/1978 |
|
Red Tag Issue Date: |
|
| Last Used Date: |
10/1/2014 |
|
Fee Due: |
$0.00 |
| Product Date: |
6/1/1978 |
|
|
|
Equipment Information
| Equipment Type |
Equipment |
Last Passing Date |
Test Expire Date |
|
Corrosion Prot - Piping
|
Impressed Current Cathodic Protection |
4/15/2014 |
4/15/2015 |
|
Corrosion Prot - Tank
|
Impressed Current Cathodic Protection |
4/15/2014 |
4/15/2015 |
|
Corrosion Prot - Tank
|
Lining Materials Internal |
10/5/2010 |
10/5/2015 |
|
Leak Detect - Piping
|
Siphon Bar |
Not applicable |
Not applicable |
|
Leak Detect - Tank
|
Automatic Tank Gauging Veeder Root TLS 350j with CSLD |
No passing test found |
No passing test found |
|
Overfill Prev Device
|
Overfill Drop Tube Valve |
No passing test found |
No passing test found |
|
Piping
|
Steel Single Wall Piping |
Not applicable |
Not applicable |
|
Spill Contain Device
|
Single Wall Spill Bucket |
No passing test found |
No passing test found |
|
Tank
|
Steel Single Wall |
Not applicable |
Not applicable |
Additional Tests
No Tests Listed
Tank Number 4
| Capacity: |
4000 |
|
Petroleum Use: |
|
| Product: |
Gasoline |
|
CERCLA Substance: |
|
| Status: |
Removed |
|
CAS Code: |
|
| Regulated Status: |
Federal |
|
Removed Date: |
3/23/2017 |
|
OSFM
First Notify Date: |
3/3/1986 |
|
Abandoned Material: |
|
| Current Age: |
38 |
|
Abandoned Date: |
|
| Install Date: |
6/1/1978 |
|
Red Tag Issue Date: |
|
| Last Used Date: |
10/1/2014 |
|
Fee Due: |
$0.00 |
| Product Date: |
6/1/1978 |
|
|
|
Equipment Information
| Equipment Type |
Equipment |
Last Passing Date |
Test Expire Date |
|
Corrosion Prot - Piping
|
Impressed Current Cathodic Protection |
4/15/2014 |
4/15/2015 |
|
Corrosion Prot - Tank
|
Impressed Current Cathodic Protection |
4/15/2014 |
4/15/2015 |
|
Corrosion Prot - Tank
|
Lining Materials Internal |
10/5/2010 |
10/5/2015 |
|
Leak Detect - Piping
|
Mechanical Pressurized Line Leak Detection |
4/15/2014 |
4/15/2015 |
|
Leak Detect - Tank
|
Automatic Tank Gauging Veeder Root TLS 350j with CSLD |
No passing test found |
No passing test found |
|
Overfill Prev Device
|
Overfill Drop Tube Valve |
No passing test found |
No passing test found |
|
Piping
|
Steel Single Wall Piping |
Not applicable |
Not applicable |
|
Spill Contain Device
|
Single Wall Spill Bucket |
No passing test found |
No passing test found |
|
Tank
|
Steel Single Wall |
Not applicable |
Not applicable |
Additional Tests
No Tests Listed
Failed test = the latest test has failed.
Not applicable = a test does not apply to this equipment type or configuration.
No passing test found = a passing test is expected but was not found from the source data.
Dispenser Information
Failed test = the latest test has failed.
Not applicable = a test does not apply to this equipment type or configuration.
No passing test found = a passing test is expected but was not found from the source data.
MFD
Motorfuel Dispensing Forms
No Forms Found