Division of Petroleum & Chemical Safety

 

Facility Details

Facility Number: 6044327
Status: Active
Facility Name: FKG Oil Company
Address: 409 South Illinois Route 3 Waterloo, IL 62298
County: Monroe
Property Parcel: 07-25-338-001
Facility Type: Attended Self-Service/Unattended Self-Service
Owner Type: Private
Green Tag Decal: AA01716
Green Tag Issue Date: 5/22/2025
Green Tag Expiration Date: 12/31/2027

Owner Details

Owner Name: Moto, Inc.
Owner Address: 721 W. Main Street Belleville, IL 62222
Owner Status: Current Owner
Purchase Date: 3/28/2023
Type of Financial Responsibility: Self-Insurance
Financial Responsibility Reporting Due Date: 10/1/2026

Motor Fuel Dispensing Permits

MFD Permit Type Issue Date Expiration Date
Self Service 5/22/2025 12/31/2027
Unattended Self Service 6/3/2021 12/31/2023

Owner Summary

Click for Facility/Tank Ownership history
Owner Number Owner Name Owner Status Purchase Date
U0010647 Moto, Inc. Current Owner 3/28/2023
U0017720 Gateway FS, Inc. Former Owner 4/23/2009
U0035280 Gateway Fast Stop Former Owner

Permits (Unexpired)

Click for permit history
Permit Number Type Status OSFM Receive Date Issue Date Expiration Date Documents
00797-2025UPG Upgrade Approved / Issued 6/25/2025 6/26/2025 12/27/2025 Documents
00796-2025ENT Tank Entry Approved / Issued 6/26/2025 6/26/2025 12/27/2025 Documents

Notice of Violatlions (Current)

No Notice of Violations Found

IEMA Numbers Associated with the Facility

No IEMA Numbers Found

LUST Fund Eligibility and Deductibility Determinations

No Applications Found

Pay Tank Fees Online

Tank Information



Tank Number 1

Capacity: 12000 Petroleum Use:
Product: Diesel Fuel CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 10/6/2009 Abandoned Material:
Current Age: 16 Abandoned Date:
Install Date: 6/12/2009 Red Tag Issue Date:
Last Used Date: Fee Due:
Product Date: 6/12/2009

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Flexible Non-Corrosive N/A N/A
Corrosion Prot - Tank Composite Non-Corrosive N/A N/A
Leak Detect - Piping Electronic Pressurized Line Leak Detection 5/22/2025 5/22/2026
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 350 with CSLD 5/22/2025 5/22/2026
Leak Detect - Tank Non-Discriminating Interstitial Monitoring Sensors 5/22/2025 5/22/2026
Overfill Prev Device Overfill Drop Tube Valve 7/17/2025 7/17/2028
Piping Flexible Double Wall A.P.T. Poly Tech P150SC N/A N/A
Piping Single Wall STP/Tanktop Sump 7/17/2025 7/17/2028
Leak Detect - Piping Sump Sensor 5/22/2025 5/22/2026
Spill Contain Device Double Wall Spill Bucket 7/17/2025 7/17/2028
Tank Composite Double Wall Modern Welding Glasteel II N/A N/A
Vent, Riser, Fill Piping Steel risers N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Flexible Double Wall A.P.T. Poly Tech P150SC Precision Test (Piping) Pass 6/6/2022
Tank Composite Double Wall Modern Welding Glasteel II Precision Test (Tank) Pass 7/17/2025



Tank Number 2

Capacity: 8000 Petroleum Use:
Product: E85 CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 10/6/2009 Abandoned Material:
Current Age: 16 Abandoned Date:
Install Date: 6/12/2009 Red Tag Issue Date:
Last Used Date: Fee Due:
Product Date: 6/12/2009

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Flexible Non-Corrosive N/A N/A
Corrosion Prot - Tank Composite Non-Corrosive N/A N/A
Leak Detect - Piping Electronic Pressurized Line Leak Detection 5/22/2025 5/22/2026
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 350 with CSLD 5/22/2025 5/22/2026
Leak Detect - Tank Non-Discriminating Interstitial Monitoring Sensors 5/22/2025 5/22/2026
Overfill Prev Device Ball Float Vent Valve EBW 308 7/17/2025 7/17/2028
Piping Flexible Double Wall A.P.T. Poly Tech P150SC N/A N/A
Piping Single Wall STP/Tanktop Sump 7/17/2025 7/17/2028
Leak Detect - Piping Sump Sensor 5/22/2025 5/22/2026
Spill Contain Device Single Wall Spill Bucket Insert 7/17/2025 7/17/2028
Tank Composite Double Wall Modern Welding Glasteel II N/A N/A
Vent, Riser, Fill Piping Steel risers N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Flexible Double Wall A.P.T. Poly Tech P150SC Precision Test (Piping) Pass 6/6/2022



Tank Number 3

Capacity: 15000 Petroleum Use:
Product: Gasoline - Regular CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 10/6/2009 Abandoned Material:
Current Age: 16 Abandoned Date:
Install Date: 6/12/2009 Red Tag Issue Date:
Last Used Date: Fee Due:
Product Date: 6/12/2009

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Flexible Non-Corrosive N/A N/A
Corrosion Prot - Tank Composite Non-Corrosive N/A N/A
Leak Detect - Piping Electronic Pressurized Line Leak Detection 5/22/2025 5/22/2026
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 350 with CSLD 5/22/2025 5/22/2026
Leak Detect - Tank Non-Discriminating Interstitial Monitoring Sensors 5/22/2025 5/22/2026
Overfill Prev Device Overfill Drop Tube Valve 7/17/2025 7/17/2028
Piping Flexible Double Wall A.P.T. Poly Tech P150SC N/A N/A
Piping Single Wall STP/Tanktop Sump 7/17/2025 7/17/2028
Leak Detect - Piping Sump Sensor 5/22/2025 5/22/2026
Spill Contain Device Single Wall Spill Bucket Insert 7/17/2025 7/17/2028
Tank Composite Double Wall Modern Welding Glasteel II N/A N/A
Vent, Riser, Fill Piping Steel risers N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Flexible Double Wall A.P.T. Poly Tech P150SC Precision Test (Piping) Pass 6/6/2022



Tank Number 4

Capacity: 5000 Petroleum Use:
Product: Gasoline - Premium CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 10/6/2009 Abandoned Material:
Current Age: 16 Abandoned Date:
Install Date: 6/12/2009 Red Tag Issue Date:
Last Used Date: Fee Due:
Product Date: 6/12/2009

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Flexible Non-Corrosive N/A N/A
Corrosion Prot - Tank Composite Non-Corrosive N/A N/A
Leak Detect - Piping Electronic Pressurized Line Leak Detection 5/22/2025 5/22/2026
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 350 with CSLD 5/22/2025 5/22/2026
Leak Detect - Tank Non-Discriminating Interstitial Monitoring Sensors 5/22/2025 5/22/2026
Overfill Prev Device Ball Float Vent Valve EBW 308 7/17/2025 7/17/2028
Piping Flexible Double Wall A.P.T. Poly Tech P150SC N/A N/A
Piping Single Wall STP/Tanktop Sump 7/17/2025 7/17/2028
Leak Detect - Piping Sump Sensor 5/22/2025 5/22/2026
Spill Contain Device Single Wall Spill Bucket 7/17/2025 7/17/2028
Tank Composite Double Wall Modern Welding Glasteel II N/A N/A
Vent, Riser, Fill Piping Steel risers N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Flexible Double Wall A.P.T. Poly Tech P150SC Precision Test (Piping) Pass 6/6/2022

Dispenser Information



Name\ID 1/2

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 7/17/2025 7/17/2028
Leak Detect - Piping Sump Sensor with positive shutdown 5/22/2025 5/22/2026



Name\ID 11/12

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 7/17/2025 7/17/2028
Leak Detect - Piping Sump Sensor with positive shutdown 5/22/2025 5/22/2026



Name\ID 13/14

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 7/17/2025 7/17/2028
Leak Detect - Piping Sump Sensor with positive shutdown 5/22/2025 5/22/2026



Name\ID 14 Satellite

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 7/17/2025 7/17/2028
Leak Detect - Piping Sump Sensor with positive shutdown 5/22/2025 5/22/2026



Name\ID 3/4

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 7/17/2025 7/17/2028
Leak Detect - Piping Sump Sensor with positive shutdown 5/22/2025 5/22/2026



Name\ID 5/6

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 7/17/2025 7/17/2028
Leak Detect - Piping Sump Sensor with positive shutdown 5/22/2025 5/22/2026



Name\ID 7/8

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 7/17/2025 7/17/2028
Leak Detect - Piping Sump Sensor with positive shutdown 5/22/2025 5/22/2026



Name\ID 9/10

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 7/17/2025 7/17/2028
Leak Detect - Piping Sump Sensor with positive shutdown 5/22/2025 5/22/2026

MFD Motorfuel Dispensing Forms

No Forms Found