Division of Petroleum & Chemical Safety

 

Facility Details

Facility Number: 6043957
Status: Closed
Facility Name: The Plaza
Address: 9221 Beller Road Mascoutah, IL 62258
County: St. Clair
Property Parcel:
Facility Type: Attended Self-Service Station
Owner Type: Private
Green Tag Decal: T002287
Green Tag Issue Date: 9/12/2018
Green Tag Expire Date: 12/31/2020
MFD Type: N/A

Owner Details

Owner Name: Hayden Petroleum, LLC
Owner Address: 138 Lincoln Place Court, Suite 102 Belleville, IL 62221
Owner Status: Current Owner
Purchase Date: 6/21/2008
Type of Financial Responsibility: Certificate of Deposit
Financial Responsibility Reporting Due Date: 8/2/2019

Owner Summary

Click for Facility/Tank Ownership history
Owner Number Owner Name Owner Status Purchase Date
U0034617 Hayden Petroleum, LLC Current Owner 6/21/2008

Permits (Unexpired)

Click for permit history

No Active Permits Found

Notice of Violations (Current)

No Notice of Violations Found

IEMA Numbers Associated with the Facility

IEMA Number Inspection Date Inspection Type Permit Number
20-0099 2/18/2020 Removal Log 00184-2020REM
20-0099 2/20/2020 Removal Log 00184-2020REM

LUST Fund Eligibility and Deductibility Determinations

IEMA Number Status OSFM Received Date OSFM Response Date Deductible Letter
20200099 Eligible 5/8/2020 5/12/2020 $5,000 Letter
Pay Tank Fees Online

Tank Information



Tank Number 1

Capacity: 20000 Petroleum Use:
Product: Gasoline - Regular CERCLA Substance:
Status: Removed CAS Code:
Regulated Status: Federal Removed Date: 2/20/2020
OSFM First Notify Date: 9/3/2008 Abandoned Material:
Current Age: 11 Abandoned Date:
Install Date: 8/29/2008 Red Tag Issue Date:
Last Used Date: 10/31/2018 Fee Due: $0.00
Product Date: 8/26/2008

Equipment Information

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Flexible Non-Corrosive Not applicable Not applicable
Corrosion Prot - Tank Composite Non-Corrosive Not applicable Not applicable
Leak Detect - Piping Electronic Pressurized Line Leak Detection 11/21/2017 11/21/2018
Leak Detect - Piping Sump Sensor 11/21/2017 11/21/2018
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 350 Plus No passing test found No passing test found
Leak Detect - Tank Non-Discriminating Interstitial Monitoring Sensors 11/21/2017 11/21/2018
Overfill Prev Device Overfill Drop Tube Valve No passing test found No passing test found
Piping Flexible Double Wall Not applicable Not applicable
Spill Contain Device Single Wall Spill Bucket No passing test found No passing test found
Tank Composite Double Wall Modern Welding Glasteel II Not applicable Not applicable
Vent, Riser, Fill Piping Steel risers Not applicable Not applicable

Additional Tests

No Tests Listed




Tank Number 2

Capacity: 12000 Petroleum Use:
Product: Gasoline - Premium CERCLA Substance:
Status: Removed CAS Code:
Regulated Status: Federal Removed Date: 2/18/2020
OSFM First Notify Date: 9/3/2008 Abandoned Material:
Current Age: 11 Abandoned Date:
Install Date: 8/29/2008 Red Tag Issue Date:
Last Used Date: 10/31/2018 Fee Due: $0.00
Product Date: 8/26/2008

Equipment Information

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Flexible Non-Corrosive Not applicable Not applicable
Corrosion Prot - Tank Composite Non-Corrosive Not applicable Not applicable
Leak Detect - Piping Electronic Pressurized Line Leak Detection 11/21/2017 11/21/2018
Leak Detect - Piping Sump Sensor 11/21/2017 11/21/2018
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 350 Plus No passing test found No passing test found
Leak Detect - Tank Non-Discriminating Interstitial Monitoring Sensors 11/21/2017 11/21/2018
Overfill Prev Device Overfill Drop Tube Valve No passing test found No passing test found
Piping Flexible Double Wall Not applicable Not applicable
Spill Contain Device Single Wall Spill Bucket No passing test found No passing test found
Tank Composite Double Wall Modern Welding Glasteel II Not applicable Not applicable
Vent, Riser, Fill Piping Steel risers Not applicable Not applicable

Additional Tests

No Tests Listed




Tank Number 3

Capacity: 8000 Petroleum Use: None
Product: Diesel Fuel CERCLA Substance:
Status: Removed CAS Code:
Regulated Status: Federal Removed Date: 2/18/2020
OSFM First Notify Date: 9/3/2008 Abandoned Material:
Current Age: 11 Abandoned Date:
Install Date: 8/29/2008 Red Tag Issue Date:
Last Used Date: 10/31/2018 Fee Due: $0.00
Product Date: 8/26/2008

Equipment Information

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Flexible Non-Corrosive Not applicable Not applicable
Corrosion Prot - Tank Composite Non-Corrosive Not applicable Not applicable
Leak Detect - Piping Electronic Pressurized Line Leak Detection 11/21/2017 11/21/2018
Leak Detect - Piping Sump Sensor 11/21/2017 11/21/2018
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 350 Plus No passing test found No passing test found
Leak Detect - Tank Non-Discriminating Interstitial Monitoring Sensors 11/21/2017 11/21/2018
Overfill Prev Device Overfill Drop Tube Valve No passing test found No passing test found
Piping Flexible Double Wall Not applicable Not applicable
Spill Contain Device Single Wall Spill Bucket No passing test found No passing test found
Tank Composite Double Wall Modern Welding Glasteel II Not applicable Not applicable
Vent, Riser, Fill Piping Steel risers Not applicable Not applicable

Additional Tests

No Tests Listed


Failed test = the latest test has failed.

Not applicable = a test does not apply to this equipment type or configuration.

No passing test found = a passing test is expected but was not found from the source data.


Dispenser Information




Failed test = the latest test has failed.

Not applicable = a test does not apply to this equipment type or configuration.

No passing test found = a passing test is expected but was not found from the source data.


MFD Motorfuel Dispensing Forms

Facility Number Name City Received Date Letter
6043957 The Plaza Mascoutah 02/01/2017 Letter Form