Division of Petroleum & Chemical Safety

 

Facility Details

Facility Number: 6032709
Status: Active
Facility Name: Fas Mart #561
Address: 101 W. Cumberland St. Elmo, IL 62458
County: Fayette
Property Parcel:
Facility Type: Attended Self-Service Station
Owner Type: Private
Green Tag Decal: AA001105
Green Tag Issue Date: 7/30/2025
Green Tag Expire Date: 12/31/2027
MFD Type: Self Service

Owner Details

Owner Name: GPM Midwest 18, LLC
Owner Address: 8565 Magellan Pkwy, Ste. 400 Richmond, VA 23227
Owner Status: Current Owner
Purchase Date: 2/18/2016
Type of Financial Responsibility: Surety Bond
Financial Responsibility Reporting Due Date: 4/29/2027

Owner Summary

Click for Facility/Tank Ownership history
Owner Number Owner Name Owner Status Purchase Date
U0038212 GPM Midwest 18, LLC Current Owner 2/18/2016
U0036467 Aving-Rice, LLC Former Owner 2/23/2012
U0033428 SNC JJ St. Elmo, LLC Former Owner 4/10/2006
U0022313 DO NOT USE Former Owner 3/1/1993
U0017339 Niebrugge Oil Company Former Owner

Permits (Unexpired)

Click for permit history

No Active Permits Found

Notice of Violations (Current)

No Notice of Violations Found

IEMA Numbers Associated with the Facility

No IEMA Numbers Found

LUST Fund Eligibility and Deductibility Determinations

No Applications Found

Pay Tank Fees Online

Tank Information



Tank Number 1

Capacity: 6000 Petroleum Use:
Product: Gasoline - Regular CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 11/17/1993 Abandoned Material:
Current Age: 39 Abandoned Date:
Install Date: 8/10/1987 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 8/10/1987

Equipment Information

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Fiberglass Non-Corrosive Not applicable Not applicable
Corrosion Prot - Tank STIP3 Cathodic Protection with Dielectric Coating 1/21/2026 1/21/2029
Leak Detect - Piping European with No Test Req Suction Not applicable Not applicable
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 450 with CSLD 1/21/2026 1/21/2027
Overfill Prev Device Overfill Drop Tube Valve 1/21/2026 1/21/2029
Piping Fiberglass Single Wall Piping Not applicable Not applicable
Piping Not Installed STP/Tanktop Sump Not applicable Not applicable
Spill Contain Device Single Wall Spill Bucket 3/18/2025 3/18/2028
Tank STIP3 Single Wall Not applicable Not applicable
Vent, Riser, Fill Piping Steel risers Not applicable Not applicable

Additional Tests

No Tests Listed




Tank Number 2

Capacity: 6000 Petroleum Use:
Product: Diesel Fuel CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 11/17/1993 Abandoned Material:
Current Age: 39 Abandoned Date:
Install Date: 8/10/1987 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 8/10/1987

Equipment Information

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Fiberglass Non-Corrosive Not applicable Not applicable
Corrosion Prot - Tank STIP3 Cathodic Protection with Dielectric Coating 1/21/2026 1/21/2029
Leak Detect - Piping European with No Test Req Suction Not applicable Not applicable
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 450 with CSLD 1/21/2026 1/21/2027
Overfill Prev Device Overfill Drop Tube Valve 1/21/2026 1/21/2029
Piping Fiberglass Single Wall Piping Not applicable Not applicable
Piping Not Installed STP/Tanktop Sump Not applicable Not applicable
Spill Contain Device Single Wall Spill Bucket 3/18/2025 3/18/2028
Tank STIP3 Single Wall Not applicable Not applicable
Vent, Riser, Fill Piping Steel risers Not applicable Not applicable

Additional Tests

No Tests Listed


Failed test = the latest test has failed.

Not applicable = a test does not apply to this equipment type or configuration.

No passing test found = a passing test is expected but was not found from the source data.


Dispenser Information



Name\ID 1/2

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump Not applicable Not applicable
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Required Not applicable Not applicable



Name\ID 3/4

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump Not applicable Not applicable
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Required Not applicable Not applicable

Failed test = the latest test has failed.

Not applicable = a test does not apply to this equipment type or configuration.

No passing test found = a passing test is expected but was not found from the source data.


MFD Motorfuel Dispensing Forms

No Forms Found