Division of Petroleum & Chemical Safety

 

Facility Details

Facility Number: 6027680
Status: Closed
Facility Name: Prairie Farms Dairy, Inc.
Address: 1800 Adams St. Granite City, IL 62040
County: Madison
Property Parcel: 22-2-19-24-07-201-002
Facility Type: Industrial / Manufacturing
Owner Type: Private
Green Tag Decal: X003666
Green Tag Issue Date: 2/16/2023
Green Tag Expiration Date: 4/12/2024

Owner Details

Owner Name: Prairie Farms Dairy, Inc.
Owner Address: 1100 North Broadway, PO Box 499 Carlinville, IL 62626
Owner Status: Current Owner
Purchase Date: 9/20/1964
Type of Financial Responsibility: Surety Bond
Financial Responsibility Reporting Due Date: 4/24/2024

Motor Fuel Dispensing Permits

MFD Permit Type Issue Date Expiration Date
Fleet 8/2/2022 12/31/2024

Owner Summary

Click for Facility/Tank Ownership history
Owner Number Owner Name Owner Status Purchase Date
U0012103 Prairie Farms Dairy, Inc. Current Owner 9/20/1964

Permits (Unexpired)

Click for permit history

No Active Permits Found

Notice of Violatlions (Current)

No Notice of Violations Found

IEMA Numbers Associated with the Facility

IEMA Number Inspection Date Inspection Type Permit Number
2024-0228 4/10/2024 Removal Log 00328-2024REM
2024-0228 4/11/2024 Removal Log 00328-2024REM

LUST Fund Eligibility and Deductibility Determinations

IEMA Number Status OSFM Received Date OSFM Response Date Deductible Letter
20240228 Eligible 5/24/2024 6/12/2024 $5,000 Letter
Pay Tank Fees Online

Tank Information



Tank Number 1

Capacity: 10000 Petroleum Use:
Product: Diesel Fuel CERCLA Substance:
Status: Abandoned in place CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 6/25/1991 Abandoned Material: Inert material mixed with portland cement
Current Age: Abandoned Date: 12/14/2000
Install Date: Red Tag Issue Date:
Last Used Date: 7/27/1998 Fee Due: $0.00
Product Date:

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date



Tank Number 2

Capacity: 8000 Petroleum Use:
Product: Gasoline CERCLA Substance:
Status: Removed CAS Code:
Regulated Status: Federal Removed Date: 10/20/1997
OSFM First Notify Date: 6/25/1991 Abandoned Material:
Current Age: Abandoned Date:
Install Date: Red Tag Issue Date:
Last Used Date: 3/1/1990 Fee Due: $0.00
Product Date:

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date



Tank Number 3

Capacity: 15000 Petroleum Use: None
Product: Diesel Fuel CERCLA Substance:
Status: Removed CAS Code:
Regulated Status: Federal Removed Date: 4/10/2024
OSFM First Notify Date: 6/25/1991 Abandoned Material:
Current Age: 37 Abandoned Date:
Install Date: 6/24/1986 Red Tag Issue Date:
Last Used Date: 10/10/2022 Fee Due: $0.00
Product Date:

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Isolation Boots Flex Connector N/A N/A
Corrosion Prot - Piping Fiberglass Non-Corrosive N/A N/A
Corrosion Prot - Tank Composite Non-Corrosive N/A N/A
Leak Detect - Piping Electronic Pressurized Line Leak Detection 9/7/2022 9/7/2023
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 350 with CSLD 9/7/2022 9/7/2023
Overfill Prev Device Ball Float Vent Valve 9/7/2022 9/7/2025
Piping Flex Connector Steel N/A N/A
Piping Fiberglass Single Wall Piping N/A N/A
Piping Not Installed STP/Tanktop Sump N/A N/A
Spill Contain Device Single Wall Spill Bucket 9/7/2022 9/7/2025
Tank Composite Single Wall N/A N/A
Vent, Riser, Fill Piping Steel risers N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Fiberglass Single Wall Piping Precision Test (Piping) Fail 9/7/2022



Tank Number 4

Capacity: 10000 Petroleum Use: None
Product: Diesel Fuel CERCLA Substance:
Status: Removed CAS Code:
Regulated Status: Federal Removed Date: 4/11/2024
OSFM First Notify Date: 11/17/1998 Abandoned Material:
Current Age: 25 Abandoned Date:
Install Date: 7/27/1998 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 7/27/1998

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Sacrificial Anode Cathodic Protection 9/7/2022 9/7/2025
Corrosion Prot - Piping Isolation Boots Flex Connector N/A N/A
Corrosion Prot - Piping Fiberglass Non-Corrosive N/A N/A
Corrosion Prot - Tank STIP3 Cathodic Protection with Dielectric Coating 9/7/2022 9/7/2025
Leak Detect - Piping Electronic Pressurized Line Leak Detection 9/19/2023 9/19/2024
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 350 with CSLD 9/19/2023 9/19/2024
Overfill Prev Device Overfill Drop Tube Valve 12/28/2022 12/28/2025
Piping Flex Connector Steel N/A N/A
Piping Fiberglass Single Wall Piping N/A N/A
Piping Not Installed STP/Tanktop Sump N/A N/A
Spill Contain Device Single Wall Spill Bucket 12/28/2022 12/28/2025
Tank STIP3 Single Wall N/A N/A
Vent, Riser, Fill Piping Steel risers N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Fiberglass Single Wall Piping Precision Test (Piping) Pass 9/19/2023



Tank Number 5

Capacity: 10000 Petroleum Use:
Product: Diesel Fuel CERCLA Substance:
Status: Removed CAS Code:
Regulated Status: Exempt Removed Date: 9/22/1986
OSFM First Notify Date: Abandoned Material:
Current Age: Abandoned Date:
Install Date: Red Tag Issue Date:
Last Used Date: 9/22/1985 Fee Due:
Product Date:

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date

Dispenser Information



Name\ID 1/2

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Not Installed UDC Sump N/A N/A



Name\ID 3.4

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Not Installed UDC Sump N/A N/A

MFD Motorfuel Dispensing Forms

No Forms Found