Facility Details
Facility Number:
6025431
Status:
Closed
Facility Name:
IDOT East St. Louis (851)
Address:
728 Exchange Ave East St. Louis, IL 62201
County:
St. Clair
Property Parcel:
00000000
Facility Type:
State
Owner Type:
State
Green Tag Decal:
Y004542
Green Tag Issue Date:
8/17/2023
Green Tag Expiration Date:
6/9/2025
Owner Details
Owner Name:
Illinois Department of Transportation
Owner Address:
2300 S. Dirksen Parkway Springfield, IL 62764
Owner Status:
Current Owner
Purchase Date:
Type of Financial Responsibility:
Self-Insurance
Financial Responsibility Reporting Due Date:
3/31/2026
Motor Fuel Dispensing Permits
MFD Permit Type
Issue Date
Expiration Date
Fleet
8/17/2023
12/31/2025
Owner Summary
Click for Facility/Tank Ownership history
Owner Number
Owner Name
Owner Status
Purchase Date
U0021798
Illinois Department of Transportation
Current Owner
U0021057
IL Dept of Transportation
Former Owner
U0007345
IL Dept. of Transportation Dist. 8
Former Owner
Permits (Unexpired)
Click for permit history
Permit Number
Type
Status
OSFM Receive Date
Issue Date
Expiration Date
Documents
00607-2025REM
Removal
Approved / Issued
5/8/2025
5/16/2025
11/18/2025
Documents
Notice of Violatlions (Current)
No Notice of Violations Found
IEMA Numbers Associated with the Facility
IEMA Number
Inspection Date
Inspection Type
Permit Number
2025-0390
5/30/2025
Removal Log
00607-2025REM
LUST
Fund Eligibility and Deductibility Determinations
No Applications Found
Pay Tank Fees Online
Tank Information
Tank Number 1
Capacity:
2500
Petroleum Use:
Product:
Diesel Fuel
CERCLA Substance:
Status:
Removed
CAS Code:
Regulated Status:
Federal
Removed Date:
3/15/1991
OSFM
First Notify Date:
4/4/1990
Abandoned Material:
Current Age:
8
Abandoned Date:
Install Date:
1/1/1983
Red Tag Issue Date:
Last Used Date:
2/15/1991
Fee Due:
$0.00
Product Date:
1/1/1983
Equipment
Equipment Type
Equipment
Last Passing Date
Test Expire Date
Additional Tests
Equipment Type
Equipment
Test Type
Test Result
Test Date
Tank Number 2
Capacity:
10000
Petroleum Use:
Product:
Diesel Fuel
CERCLA Substance:
Status:
Removed
CAS Code:
Regulated Status:
Federal
Removed Date:
5/30/2025
OSFM
First Notify Date:
11/13/1992
Abandoned Material:
Current Age:
34
Abandoned Date:
Install Date:
3/1/1991
Red Tag Issue Date:
Last Used Date:
Fee Due:
$0.00
Product Date:
3/6/1991
Equipment
Equipment Type
Equipment
Last Passing Date
Test Expire Date
Corrosion Prot - Piping
Isolation Boots Flex Connector
N/A
N/A
Corrosion Prot - Piping
Fiberglass Non-Corrosive
N/A
N/A
Corrosion Prot - Tank
Fiberglass Non-Corrosive
N/A
N/A
Leak Detect - Piping
Mechanical Pressurized Line Leak Detection
6/17/2024
6/17/2025
Leak Detect - Tank
Automatic Tank Gauging Veeder Root TLS 350 with CSLD
6/17/2024
6/17/2025
Overfill Prev Device
Overfill Drop Tube Valve
7/1/2022
7/1/2025
Piping
Fiberglass Single Wall Piping
N/A
N/A
Piping
Not Installed STP/Tanktop Sump
N/A
N/A
Spill Contain Device
Single Wall Spill Bucket
7/1/2022
7/1/2025
Tank
Fiberglass Single Wall
N/A
N/A
Vent, Riser, Fill Piping
Steel risers
N/A
N/A
Additional Tests
Equipment Type
Equipment
Test Type
Test Result
Test Date
Piping
Fiberglass Single Wall Piping
Precision Test (Piping)
Pass
6/17/2024
Tank Number 3
Capacity:
2000
Petroleum Use:
Product:
Diesel Fuel
CERCLA Substance:
Status:
Removed
CAS Code:
Regulated Status:
Federal
Removed Date:
5/11/2011
OSFM
First Notify Date:
11/13/1992
Abandoned Material:
Current Age:
20
Abandoned Date:
Install Date:
3/1/1991
Red Tag Issue Date:
Last Used Date:
Fee Due:
$0.00
Product Date:
3/6/1991
Equipment
Equipment Type
Equipment
Last Passing Date
Test Expire Date
Corrosion Prot - Piping
Fiberglass Non-Corrosive
N/A
N/A
Corrosion Prot - Tank
Fiberglass Non-Corrosive
N/A
N/A
Leak Detect - Piping
Pressurized Line Leak Detection
Leak Detect - Tank
Automatic Tank Gauging Veeder Root TLS 350 with CSLD
Overfill Prev Device
Overfill Drop Tube Valve
Piping
Fiberglass Single Wall Piping
N/A
N/A
Spill Contain Device
Manhole Field Constructed
Tank
Fiberglass Single Wall
N/A
N/A
Additional Tests
Equipment Type
Equipment
Test Type
Test Result
Test Date
Dispenser Information
Name\ID 1/2
Status:
Active
Equipment Type
Equipment
Last Passing Date
Test Expire Date
Dispenser
Not Installed UDC Sump
N/A
N/A
MFD
Motorfuel Dispensing Forms
No Forms Found