Division of Petroleum & Chemical Safety

 

Facility Details

Facility Number: 6024460
Status: Active
Facility Name: CC Food Mart
Address: Route 161 & White Oaks Drive New Baden, IL 62265
County: Clinton
Property Parcel: 10-13.0-203-017
Facility Type: Attended Self-Service Station
Owner Type: Private
Green Tag Decal: AA01111
Green Tag Issue Date: 8/8/2025
Green Tag Expiration Date: 12/31/2027

Owner Details

Owner Name: Clinton County Oil Company, Inc.
Owner Address: P.O. Box 155 Breese, IL 62230
Owner Status: Current Owner
Purchase Date:
Type of Financial Responsibility: Letter of Credit
Financial Responsibility Reporting Due Date: 1/15/2026

Motor Fuel Dispensing Permits

MFD Permit Type Issue Date Expiration Date
Self Service 8/8/2025 12/31/2027

Owner Summary

Click for Facility/Tank Ownership history
Owner Number Owner Name Owner Status Purchase Date
U0003121 Clinton County Oil Company, Inc. Current Owner

Permits (Unexpired)

Click for permit history

No Active Permits Found

Notice of Violatlions (Current)

No Notice of Violations Found

IEMA Numbers Associated with the Facility

No IEMA Numbers Found

LUST Fund Eligibility and Deductibility Determinations

No Applications Found

Pay Tank Fees Online

Tank Information



Tank Number 1

Capacity: 10000 Petroleum Use:
Product: Gasoline - Premium CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 10/7/1988 Abandoned Material:
Current Age: 36 Abandoned Date:
Install Date: 10/7/1988 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date:

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Isolation Boots Flex Connector N/A N/A
Corrosion Prot - Piping Fiberglass Non-Corrosive N/A N/A
Corrosion Prot - Tank STIP3 Cathodic Protection with Dielectric Coating 11/23/2022 11/23/2025
Leak Detect - Piping Electronic Pressurized Line Leak Detection 4/8/2025 4/8/2026
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 350j with CSLD 4/8/2025 4/8/2026
Overfill Prev Device Overfill Drop Tube Valve 4/8/2025 4/8/2028
Piping Fiberglass Double Wall N/A N/A
Piping Not Installed STP/Tanktop Sump N/A N/A
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Installed N/A N/A
Spill Contain Device Single Wall Spill Bucket 4/8/2025 4/8/2028
Tank STIP3 Single Wall N/A N/A
Vent, Riser, Fill Piping Steel risers N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date



Tank Number 2

Capacity: 10000 Petroleum Use:
Product: Gasoline - Regular CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 10/7/1988 Abandoned Material:
Current Age: 36 Abandoned Date:
Install Date: 10/7/1988 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date:

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Isolation Boots Flex Connector N/A N/A
Corrosion Prot - Piping Fiberglass Non-Corrosive N/A N/A
Corrosion Prot - Tank STIP3 Cathodic Protection with Dielectric Coating 11/23/2022 11/23/2025
Leak Detect - Piping Electronic Pressurized Line Leak Detection 4/8/2025 4/8/2026
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 350j with CSLD 4/8/2025 4/8/2026
Overfill Prev Device Overfill Drop Tube Valve 4/8/2025 4/8/2028
Piping Fiberglass Double Wall N/A N/A
Piping Not Installed STP/Tanktop Sump N/A N/A
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Installed N/A N/A
Spill Contain Device Single Wall Spill Bucket 4/8/2025 4/8/2028
Tank STIP3 Single Wall N/A N/A
Vent, Riser, Fill Piping Steel risers N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date



Tank Number 3

Capacity: 12000 Petroleum Use:
Product: Gasoline - Regular CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 10/7/1988 Abandoned Material:
Current Age: 36 Abandoned Date:
Install Date: 10/7/1988 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date:

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Isolation Boots Flex Connector N/A N/A
Corrosion Prot - Piping Fiberglass Non-Corrosive N/A N/A
Corrosion Prot - Tank STIP3 Cathodic Protection with Dielectric Coating 11/23/2022 11/23/2025
Leak Detect - Piping Electronic Pressurized Line Leak Detection 5/12/2025 5/12/2026
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 350j with CSLD 4/8/2025 4/8/2026
Overfill Prev Device Overfill Drop Tube Valve 4/8/2025 4/8/2028
Piping Fiberglass Double Wall N/A N/A
Piping Not Installed STP/Tanktop Sump N/A N/A
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Installed N/A N/A
Spill Contain Device Single Wall Spill Bucket 4/8/2025 4/8/2028
Tank STIP3 Single Wall N/A N/A
Vent, Riser, Fill Piping Steel risers N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date



Tank Number 4

Capacity: 12000 Petroleum Use:
Product: B-11 CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 10/7/1988 Abandoned Material:
Current Age: 36 Abandoned Date:
Install Date: 10/7/1988 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date:

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Isolation Boots Flex Connector N/A N/A
Corrosion Prot - Piping Fiberglass Non-Corrosive N/A N/A
Corrosion Prot - Tank STIP3 Cathodic Protection with Dielectric Coating 11/23/2022 11/23/2025
Leak Detect - Piping Electronic Pressurized Line Leak Detection 4/8/2025 4/8/2026
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 350j with CSLD 4/8/2025 4/8/2026
Overfill Prev Device Overfill Drop Tube Valve 4/8/2025 4/8/2028
Piping Fiberglass Double Wall N/A N/A
Piping Not Installed STP/Tanktop Sump N/A N/A
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Installed N/A N/A
Spill Contain Device Single Wall Spill Bucket 4/8/2025 4/8/2028
Tank STIP3 Single Wall N/A N/A
Vent, Riser, Fill Piping Steel risers N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date

Dispenser Information



Name\ID 1/2

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Not Installed UDC Sump N/A N/A
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Installed N/A N/A



Name\ID 3/4

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Not Installed UDC Sump N/A N/A
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Installed N/A N/A



Name\ID 5/6

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Not Installed UDC Sump N/A N/A
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Installed N/A N/A



Name\ID 7/8 Diesel

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Not Installed UDC Sump N/A N/A
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Installed N/A N/A

MFD Motorfuel Dispensing Forms

No Forms Found