Division of Petroleum & Chemical Safety

 

Facility Details

Facility Number: 6024132
Status: Closed
Facility Name: PAK-AGS, Inc.
Address: 2526 Nameoki Road
Granite City, IL 62040
County: Madison
Property Parcel:
Facility Type: Attended Self-Service Station
Owner Type: Private
Green Tag Decal: G002006
Green Tag Issue Date: 1/4/2006
Green Tag Expiration Date: 12/31/2008

Owner Details

Owner Name: PAK-AGS, Inc.
Owner Address: 2526 Nameoki Rd.
Granite City, IL 62040
Owner Status: Current Owner
Purchase Date: 3/1/2007
Type of Financial Responsibility: Commercial Insurance
Financial Responsibility Reporting Due Date: 2/10/2012

Motor Fuel Dispensing Permits

MFD Permit Type Issue Date Expiration Date
Self Service 3/25/2004 4/1/2005

Owner Summary

Click for Facility/Tank Ownership history
Owner Number Owner Name Owner Status Purchase Date
U0036055 PAK-AGS, Inc. Current Owner 3/1/2007
U0033623 N and S Service, Inc. Former Owner 12/21/2005
U0003444 T C L S Inc. dba/Corner Liquor Store Former Owner

Permits (Unexpired)

Click for permit history

No Active Permits Found

Notice of Violations (Current)

No Notice of Violations Found

IEMA Numbers Associated with the Facility

IEMA Number Inspection Date Inspection Type Permit Number
11-0945 10/5/2011 Removal Log 00914-2011REM
11-0945 10/6/2011 Removal Log 00914-2011REM

LUST Fund Eligibility and Deductibility Determinations

IEMA Number Status OSFM Received Date OSFM Response Date Deductible Letter
05-0545 Returned 9/7/2011 11/2/2011 $Not Selected
11-0945 Eligible 2/14/2012 3/23/2012 $5,000
Pay Tank Fees Online

Tank Information



Tank Number 1

Capacity: 10000 Petroleum Use:
Product: Gasoline CERCLA Substance:
Status: Removed CAS Code:
Regulated Status: Federal Removed Date: 10/5/2011
OSFM First Notify Date: 4/14/1987 Abandoned Material:
Current Age: 25 Abandoned Date:
Install Date: 1/1/1986 Red Tag Issue Date:
Last Used Date: 9/22/2008 Fee Due: $0.00
Product Date:

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Impressed Current Cathodic Protection 1/1/1999 1/1/2000
Corrosion Prot - Tank Impressed Current Cathodic Protection 1/1/1999 1/1/2000
Leak Detect - Piping Mechanical Pressurized Line Leak Detection 1/1/1999 1/1/2000
Leak Detect - Tank Monthly Inv Ctrl and Prec Tight Testing 1/1/1999 1/1/2000
Overfill Prev Device Ball Float Vent Valve
Piping Steel Single Wall Piping N/A N/A
Spill Contain Device Single Wall Spill Bucket
Tank Steel Single Wall N/A N/A
Vent, Riser, Fill Piping Steel risers N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date



Tank Number 2

Capacity: 10000 Petroleum Use:
Product: Gasoline CERCLA Substance:
Status: Removed CAS Code:
Regulated Status: Federal Removed Date: 10/6/2011
OSFM First Notify Date: 4/14/1987 Abandoned Material:
Current Age: 34 Abandoned Date:
Install Date: 4/1/1977 Red Tag Issue Date:
Last Used Date: 9/22/2008 Fee Due: $0.00
Product Date:

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Impressed Current Cathodic Protection 1/1/1999 1/1/2000
Corrosion Prot - Tank Impressed Current Cathodic Protection 1/1/1999 1/1/2000
Leak Detect - Piping Mechanical Pressurized Line Leak Detection 1/1/1999 1/1/2000
Leak Detect - Tank Monthly Inv Ctrl and Prec Tight Testing 1/1/1999 1/1/2000
Overfill Prev Device Ball Float Vent Valve
Piping Steel Single Wall Piping N/A N/A
Spill Contain Device Single Wall Spill Bucket
Tank Steel Single Wall N/A N/A
Vent, Riser, Fill Piping Steel risers N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date



Tank Number 3

Capacity: 10000 Petroleum Use:
Product: Gasoline CERCLA Substance:
Status: Removed CAS Code:
Regulated Status: Federal Removed Date: 10/6/2011
OSFM First Notify Date: 4/14/1987 Abandoned Material:
Current Age: 34 Abandoned Date:
Install Date: 4/1/1977 Red Tag Issue Date:
Last Used Date: 9/22/2008 Fee Due: $0.00
Product Date:

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Impressed Current Cathodic Protection 1/1/1999 1/1/2000
Corrosion Prot - Tank Impressed Current Cathodic Protection 1/1/1999 1/1/2000
Leak Detect - Piping Mechanical Pressurized Line Leak Detection 1/1/1999 1/1/2000
Leak Detect - Tank Monthly Inv Ctrl and Prec Tight Testing 1/1/1999 1/1/2000
Overfill Prev Device Ball Float Vent Valve
Piping Steel Single Wall Piping N/A N/A
Spill Contain Device Single Wall Spill Bucket
Tank Steel Single Wall N/A N/A
Vent, Riser, Fill Piping Steel risers N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date

Dispenser Information



MFD Motorfuel Dispensing Forms

No Forms Found