Information
JB Pritzker, Governor
James A. Rivera, State Fire Marshal
Division of Petroleum & Chemical Safety
State of Illinois
Employment Opportunities
Ready Illinois
Find us on Facebook
UST
Search
Contractor Search
Permit Search
Disclaimer & Rules/Statutes
Disclaimer
Rules
Statutes
Statistics & Reports
Statistics
Red Tag Tanks
Blended Fuel Tanks
Federal Energy Act Reports
Help
Division of Petroleum & Chemical Safety
Facility Details
Facility Number:
6005850
Status:
Closed
Facility Name:
Parkash K, LLC
Address:
609 East 15th Street
Centralia, IL 62801
County:
Marion
Property Parcel:
14-19-200-012
Facility Type:
Attended Self-Service Station
Owner Type:
Private
Green Tag Decal:
O00317
Green Tag Issue Date:
7/30/2013
Green Tag Expiration Date:
12/31/2015
Owner Details
Owner Name:
Parkash K, LLC
Owner Address:
609 East 15th Street
Centralia, IL 62801
Owner Status:
Current Owner
Purchase Date:
9/21/2017
Type of Financial Responsibility:
Commercial Insurance
Financial Responsibility Reporting Due Date:
10/11/2018
Motor Fuel Dispensing Permits
MFD Permit Type
Issue Date
Expiration Date
Self Service
7/30/2013
12/31/2015
Owner Summary
Click for Facility/Tank Ownership history
Owner Number
Owner Name
Owner Status
Purchase Date
U0038943
Parkash K, LLC
Current Owner
9/21/2017
U0038871
Singh, Gurwinder
Former Owner
8/8/2017
U0021645
HCTK, Inc.
Former Owner
7/1/1996
U0010603
Morgon Land Co Inc
Former Owner
12/31/1967
Permits (Unexpired)
Click for permit history
No Active Permits Found
Notice of Violations (Current)
No Notice of Violations Found
IEMA Numbers Associated with the Facility
IEMA Number
Inspection Date
Inspection Type
Permit Number
17-0840
10/31/2017
Removal Log
01230-2017REM
17-0840
11/1/2017
Removal Log
01230-2017REM
LUST
Fund Eligibility and Deductibility Determinations
IEMA Number
Status
OSFM Received Date
OSFM Response Date
Deductible
Letter
20170840
Eligible
1/16/2018
1/19/2018
$5,000
Letter
Pay Tank Fees Online
Tank Information
Tank Number 1
Capacity:
10000
Petroleum Use:
Product:
Gasoline
CERCLA Substance:
Status:
Removed
CAS Code:
Regulated Status:
Federal
Removed Date:
10/31/2017
OSFM
First Notify Date:
9/5/1987
Abandoned Material:
Current Age:
30
Abandoned Date:
Install Date:
9/14/1987
Red Tag Issue Date:
Last Used Date:
1/12/2015
Fee Due:
$0.00
Product Date:
Equipment
Equipment Type
Equipment
Last Passing Date
Test Expire Date
Corrosion Prot - Piping
Sacrificial Anode Cathodic Protection
7/23/2013
7/23/2016
Corrosion Prot - Piping
Fiberglass Non-Corrosive
N/A
N/A
Corrosion Prot - Tank
STIP3 Cathodic Protection with Dielectric Coating
7/23/2013
7/23/2016
Leak Detect - Piping
Mechanical Pressurized Line Leak Detection
7/23/2013
7/23/2014
Leak Detect - Tank
Automatic Tank Gauging Veeder Root TLS 300
Overfill Prev Device
Overfill Drop Tube Valve
Piping
Fiberglass Single Wall Piping
N/A
N/A
Spill Contain Device
Single Wall Spill Bucket
Tank
STIP3 Single Wall
N/A
N/A
Vent, Riser, Fill Piping
Steel risers
N/A
N/A
Additional Tests
Equipment Type
Equipment
Test Type
Test Result
Test Date
Tank Number 2
Capacity:
10000
Petroleum Use:
Product:
Gasoline
CERCLA Substance:
Status:
Removed
CAS Code:
Regulated Status:
Federal
Removed Date:
11/1/2017
OSFM
First Notify Date:
9/5/1987
Abandoned Material:
Current Age:
30
Abandoned Date:
Install Date:
9/14/1987
Red Tag Issue Date:
Last Used Date:
1/12/2015
Fee Due:
$0.00
Product Date:
Equipment
Equipment Type
Equipment
Last Passing Date
Test Expire Date
Corrosion Prot - Piping
Sacrificial Anode Cathodic Protection
7/23/2013
7/23/2016
Corrosion Prot - Piping
Fiberglass Non-Corrosive
N/A
N/A
Corrosion Prot - Tank
STIP3 Cathodic Protection with Dielectric Coating
7/23/2013
7/23/2016
Leak Detect - Piping
Mechanical Pressurized Line Leak Detection
7/23/2013
7/23/2014
Leak Detect - Tank
Automatic Tank Gauging Veeder Root TLS 300
Overfill Prev Device
Overfill Drop Tube Valve
Piping
Fiberglass Single Wall Piping
N/A
N/A
Spill Contain Device
Single Wall Spill Bucket
Tank
STIP3 Single Wall
N/A
N/A
Vent, Riser, Fill Piping
Steel risers
N/A
N/A
Additional Tests
Equipment Type
Equipment
Test Type
Test Result
Test Date
Tank Number 3
Capacity:
10000
Petroleum Use:
Consumptive Use on Premises for Heating
Product:
Diesel Fuel
CERCLA Substance:
Status:
Removed
CAS Code:
Regulated Status:
State
Removed Date:
11/1/2017
OSFM
First Notify Date:
9/5/1987
Abandoned Material:
Current Age:
30
Abandoned Date:
Install Date:
9/14/1987
Red Tag Issue Date:
Last Used Date:
1/12/2015
Fee Due:
$0.00
Product Date:
Equipment
Equipment Type
Equipment
Last Passing Date
Test Expire Date
Corrosion Prot - Piping
Sacrificial Anode Cathodic Protection
7/23/2013
7/23/2016
Corrosion Prot - Piping
Fiberglass Non-Corrosive
N/A
N/A
Corrosion Prot - Tank
STIP3 Cathodic Protection with Dielectric Coating
7/23/2013
7/23/2016
Leak Detect - Piping
Mechanical Pressurized Line Leak Detection
7/23/2013
7/23/2014
Leak Detect - Tank
Automatic Tank Gauging Veeder Root TLS 300
Overfill Prev Device
Overfill Drop Tube Valve
Piping
Fiberglass Single Wall Piping
N/A
N/A
Spill Contain Device
Single Wall Spill Bucket
Tank
STIP3 Single Wall
N/A
N/A
Vent, Riser, Fill Piping
Steel risers
N/A
N/A
Additional Tests
Equipment Type
Equipment
Test Type
Test Result
Test Date
Dispenser Information
MFD
Motorfuel Dispensing Forms
No Forms Found