Facility Details
Facility Number:
6001337
Status:
Closed
Facility Name:
Gas-N-Go
Address:
110 E. Harris
Greenville, IL 62246
County:
Bond
Property Parcel:
Facility Type:
Attended Self-Service Station
Owner Type:
Private
Green Tag Decal:
F002624
Green Tag Issue Date:
10/25/2004
Green Tag Expiration Date:
12/31/2007
Owner Details
Owner Name:
Green Oil Company
Owner Address:
2007 North Kickapoo
PO Box 800
Lincoln, IL 62656
Owner Status:
Current Owner
Purchase Date:
Type of Financial Responsibility:
Self-Insurance
Financial Responsibility Reporting Due Date:
11/5/2010
Motor Fuel Dispensing Permits
No MFD Permits Found
Owner Summary
Click for Facility/Tank Ownership history
Owner Number
Owner Name
Owner Status
Purchase Date
U0006126
Green Oil Company
Current Owner
U0032508
Sam Carpenter Enterprises, Inc.
Former Owner
10/26/2004
U0006126
Green Oil Company
Former Owner
1/1/1990
U0008410
Kerr Mcgee Refining Corp
Former Owner
12/31/1967
Permits (Unexpired)
Click for permit history
No Active Permits Found
Notice of Violations (Current)
No Notice of Violations Found
IEMA Numbers Associated with the Facility
IEMA Number
Inspection Date
Inspection Type
Permit Number
10-0879
9/14/2010
Removal Log
00966-2010REM
LUST
Fund Eligibility and Deductibility Determinations
IEMA Number
Status
OSFM Received Date
OSFM Response Date
Deductible
Letter
89-2025
Eligible
3/3/1997
3/24/1997
$10,000
06-0067
Eligible
7/3/2006
8/2/2006
$10,000
10-0879
Eligible
8/19/2010
9/28/2010
$5,000
Pay Tank Fees Online
Tank Information
Tank Number 4
Capacity:
10000
Petroleum Use:
Product:
Gasoline
CERCLA Substance:
Status:
Removed
CAS Code:
Regulated Status:
Federal
Removed Date:
9/14/2010
OSFM
First Notify Date:
12/15/1989
Abandoned Material:
Current Age:
20
Abandoned Date:
Install Date:
11/1/1989
Red Tag Issue Date:
Last Used Date:
6/5/2007
Fee Due:
$0.00
Product Date:
Equipment
Equipment Type
Equipment
Last Passing Date
Test Expire Date
Corrosion Prot - Piping
Fiberglass Non-Corrosive
N/A
N/A
Corrosion Prot - Tank
Fiberglass Non-Corrosive
N/A
N/A
Leak Detect - Piping
Pressurized Line Leak Detection
Leak Detect - Tank
Automatic Tank Gauging Incon TS 750
Overfill Prev Device
Ball Float Vent Valve
Piping
Fiberglass Single Wall Piping
N/A
N/A
Spill Contain Device
Manhole Field Constructed
Tank
Fiberglass Single Wall
N/A
N/A
Additional Tests
Equipment Type
Equipment
Test Type
Test Result
Test Date
Tank Number 5
Capacity:
10000
Petroleum Use:
Product:
Gasoline
CERCLA Substance:
Status:
Removed
CAS Code:
Regulated Status:
Federal
Removed Date:
9/14/2010
OSFM
First Notify Date:
12/15/1989
Abandoned Material:
Current Age:
20
Abandoned Date:
Install Date:
11/1/1989
Red Tag Issue Date:
Last Used Date:
1/13/2006
Fee Due:
$0.00
Product Date:
Equipment
Equipment Type
Equipment
Last Passing Date
Test Expire Date
Corrosion Prot - Piping
Fiberglass Non-Corrosive
N/A
N/A
Corrosion Prot - Tank
Fiberglass Non-Corrosive
N/A
N/A
Leak Detect - Piping
Pressurized Line Leak Detection
Leak Detect - Tank
Automatic Tank Gauging Incon TS 750
Overfill Prev Device
Ball Float Vent Valve
Piping
Fiberglass Single Wall Piping
N/A
N/A
Spill Contain Device
Manhole Field Constructed
Tank
Fiberglass Single Wall
N/A
N/A
Additional Tests
Equipment Type
Equipment
Test Type
Test Result
Test Date
Tank Number 6
Capacity:
10000
Petroleum Use:
Product:
Gasoline
CERCLA Substance:
Status:
Removed
CAS Code:
Regulated Status:
Federal
Removed Date:
10/12/1989
OSFM
First Notify Date:
3/3/1986
Abandoned Material:
Current Age:
14
Abandoned Date:
Install Date:
1/1/1975
Red Tag Issue Date:
Last Used Date:
10/1/1989
Fee Due:
$0.00
Product Date:
1/1/1975
Equipment
Equipment Type
Equipment
Last Passing Date
Test Expire Date
Additional Tests
Equipment Type
Equipment
Test Type
Test Result
Test Date
Tank Number 7
Capacity:
6000
Petroleum Use:
Product:
Gasoline
CERCLA Substance:
Status:
Removed
CAS Code:
Regulated Status:
Federal
Removed Date:
10/12/1989
OSFM
First Notify Date:
3/3/1986
Abandoned Material:
Current Age:
14
Abandoned Date:
Install Date:
1/1/1975
Red Tag Issue Date:
Last Used Date:
10/1/1989
Fee Due:
$0.00
Product Date:
1/1/1975
Equipment
Equipment Type
Equipment
Last Passing Date
Test Expire Date
Additional Tests
Equipment Type
Equipment
Test Type
Test Result
Test Date
Tank Number 8
Capacity:
300
Petroleum Use:
Product:
Used Oil
CERCLA Substance:
Status:
Removed
CAS Code:
Regulated Status:
Federal
Removed Date:
10/13/1989
OSFM
First Notify Date:
3/3/1986
Abandoned Material:
Current Age:
14
Abandoned Date:
Install Date:
1/1/1975
Red Tag Issue Date:
Last Used Date:
10/1/1989
Fee Due:
$0.00
Product Date:
1/1/1975
Equipment
Equipment Type
Equipment
Last Passing Date
Test Expire Date
Additional Tests
Equipment Type
Equipment
Test Type
Test Result
Test Date
Dispenser Information
MFD
Motorfuel Dispensing Forms
No Forms Found