Division of Petroleum & Chemical Safety

 

Facility Details

Facility Number: 6000699
Status: Active
Facility Name: Little Nashville Truck Stop, LLC d/b/a Little Nashville Truck Stop
Address: 11700 State Route 127 Nashville, IL 62263
County: Washington
Property Parcel: 02-13-06-100-011
Facility Type: Attended Self-Service Station
Owner Type: Private
Green Tag Decal: Z001792
Green Tag Issue Date: 9/10/2024
Green Tag Expiration Date: 12/31/2026

Owner Details

Owner Name: Waif Rackley Land Investment, LLC
Owner Address: P.O. Box 100 West Alton, MO 63386
Owner Status: Current Owner
Purchase Date: 3/22/2017
Type of Financial Responsibility: Designated Savings Account
Financial Responsibility Reporting Due Date: 8/25/2026

Motor Fuel Dispensing Permits

MFD Permit Type Issue Date Expiration Date
Self Service 9/10/2024 12/31/2026

Owner Summary

Click for Facility/Tank Ownership history
Owner Number Owner Name Owner Status Purchase Date
U0038772 Waif Rackley Land Investment, LLC Current Owner 3/22/2017
U0009254 Little Nashville, Inc. Former Owner 6/1/1984
U0009254 Little Nashville, Inc. Former Owner 6/1/1984

Permits (Unexpired)

Click for permit history

No Active Permits Found

Notice of Violatlions (Current)

No Notice of Violations Found

IEMA Numbers Associated with the Facility

IEMA Number Inspection Date Inspection Type Permit Number
08-0816 6/9/2008 Removal Log 00560-2008REM

LUST Fund Eligibility and Deductibility Determinations

IEMA Number Status OSFM Received Date OSFM Response Date Deductible Letter
08-0284 Eligible 3/11/2008 4/1/2008 $10,000
Pay Tank Fees Online

Tank Information



Tank Number 1

Capacity: 6000 Petroleum Use:
Product: Gasoline CERCLA Substance:
Status: Removed CAS Code:
Regulated Status: Federal Removed Date: 6/9/2008
OSFM First Notify Date: 1/31/1986 Abandoned Material:
Current Age: 24 Abandoned Date:
Install Date: 6/10/1984 Red Tag Issue Date:
Last Used Date: 2/25/2008 Fee Due: $0.00
Product Date: 6/12/1984

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Tank Lining Materials Internal

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date



Tank Number 2

Capacity: 12000 Petroleum Use:
Product: Gasoline CERCLA Substance:
Status: Removed CAS Code:
Regulated Status: Federal Removed Date: 6/9/2008
OSFM First Notify Date: 1/31/1986 Abandoned Material:
Current Age: 24 Abandoned Date:
Install Date: 6/10/1984 Red Tag Issue Date:
Last Used Date: 2/25/2008 Fee Due: $0.00
Product Date: 6/12/1984

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Tank Lining Materials Internal

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date



Tank Number 3

Capacity: 12000 Petroleum Use:
Product: Diesel Fuel CERCLA Substance:
Status: Removed CAS Code:
Regulated Status: Federal Removed Date: 6/9/2008
OSFM First Notify Date: 1/31/1986 Abandoned Material:
Current Age: 24 Abandoned Date:
Install Date: 6/10/1984 Red Tag Issue Date:
Last Used Date: 2/25/2008 Fee Due: $0.00
Product Date: 6/12/1984

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Tank Lining Materials Internal

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date



Tank Number 4

Capacity: 12000 Petroleum Use:
Product: Diesel Fuel CERCLA Substance:
Status: Removed CAS Code:
Regulated Status: Federal Removed Date: 6/9/2008
OSFM First Notify Date: 1/31/1986 Abandoned Material:
Current Age: 24 Abandoned Date:
Install Date: 6/10/1984 Red Tag Issue Date:
Last Used Date: 2/25/2008 Fee Due: $0.00
Product Date: 6/12/1984

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Tank Lining Materials Internal

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date



Tank Number 5

Capacity: 10000 Petroleum Use:
Product: Gasoline - Regular CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 9/15/2008 Abandoned Material:
Current Age: 17 Abandoned Date:
Install Date: 6/17/2008 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 6/17/2008

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Isolation Boots Flex Connector N/A N/A
Corrosion Prot - Piping Fiberglass Non-Corrosive N/A N/A
Corrosion Prot - Tank Fiberglass Non-Corrosive N/A N/A
Leak Detect - Piping Mechanical Pressurized Line Leak Detection 2/6/2025 2/6/2026
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 350 with CSLD 2/6/2025 2/6/2026
Leak Detect - Tank Non-Discriminating Interstitial Monitoring Sensors 2/6/2025 2/6/2026
Overfill Prev Device Ball Float Vent Valve OPW 53V 2/6/2025 2/6/2028
Piping Fiberglass Single Wall Piping N/A N/A
Piping Not Installed STP/Tanktop Sump N/A N/A
Spill Contain Device Single Wall Spill Bucket 2/6/2025 2/6/2028
Tank Fiberglass Double Wall Containment Solutions N/A N/A
Vent, Riser, Fill Piping Steel risers N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Fiberglass Single Wall Piping Precision Test (Piping) Pass 5/7/2025



Tank Number 6

Capacity: 10000 Petroleum Use:
Product: B-11 CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 9/15/2008 Abandoned Material:
Current Age: 17 Abandoned Date:
Install Date: 6/17/2008 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 6/17/2008

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Isolation Boots Flex Connector N/A N/A
Corrosion Prot - Piping Fiberglass Non-Corrosive N/A N/A
Corrosion Prot - Tank Fiberglass Non-Corrosive N/A N/A
Leak Detect - Piping Electronic Pressurized Line Leak Detection 2/6/2025 2/6/2026
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 350 with CSLD 2/6/2025 2/6/2026
Leak Detect - Tank Non-Discriminating Interstitial Monitoring Sensors 2/6/2025 2/6/2026
Overfill Prev Device Ball Float Vent Valve OPW 53V 2/6/2025 2/6/2028
Piping Fiberglass Single Wall Piping N/A N/A
Piping Not Installed STP/Tanktop Sump N/A N/A
Spill Contain Device Double Wall Spill Bucket 4/22/2025 4/22/2028
Tank Fiberglass Double Wall Containment Solutions N/A N/A
Vent, Riser, Fill Piping Steel risers N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date



Tank Number 7

Capacity: 10000 Petroleum Use:
Product: B-11 CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 9/15/2008 Abandoned Material:
Current Age: 17 Abandoned Date:
Install Date: 6/17/2008 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 6/17/2008

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Isolation Boots Flex Connector N/A N/A
Corrosion Prot - Piping Fiberglass Non-Corrosive N/A N/A
Corrosion Prot - Tank Fiberglass Non-Corrosive N/A N/A
Leak Detect - Piping Mechanical Other Non-vented check valve N/A N/A
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 350 with CSLD 2/6/2025 2/6/2026
Leak Detect - Tank Non-Discriminating Interstitial Monitoring Sensors 2/6/2025 2/6/2026
Overfill Prev Device Overfill Drop Tube Valve 2/6/2025 2/6/2028
Piping Fiberglass Single Wall Piping N/A N/A
Piping Not Installed STP/Tanktop Sump N/A N/A
Spill Contain Device Single Wall Spill Bucket 2/6/2025 2/6/2028
Tank Fiberglass Double Wall Containment Solutions N/A N/A
Vent, Riser, Fill Piping Steel risers N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date



Tank Number 8

Capacity: 4000 Petroleum Use:
Product: Gasoline - Premium CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 9/15/2008 Abandoned Material:
Current Age: 17 Abandoned Date:
Install Date: 6/17/2008 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 6/17/2008

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Isolation Boots Flex Connector N/A N/A
Corrosion Prot - Piping Fiberglass Non-Corrosive N/A N/A
Corrosion Prot - Tank Fiberglass Non-Corrosive N/A N/A
Leak Detect - Piping Mechanical Pressurized Line Leak Detection 2/6/2025 2/6/2026
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 350 with CSLD 2/6/2025 2/6/2026
Leak Detect - Tank Non-Discriminating Interstitial Monitoring Sensors 2/6/2025 2/6/2026
Overfill Prev Device Overfill Drop Tube Valve 2/6/2025 2/6/2028
Piping Fiberglass Single Wall Piping N/A N/A
Piping Not Installed STP/Tanktop Sump N/A N/A
Spill Contain Device Single Wall Spill Bucket 2/6/2025 2/6/2028
Tank Fiberglass Double Wall Containment Solutions N/A N/A
Vent, Riser, Fill Piping Steel risers N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Fiberglass Single Wall Piping Precision Test (Piping) Pass 2/6/2025

Dispenser Information



Name\ID 1/2

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Not Installed UDC Sump N/A N/A



Name\ID 3/4

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Not Installed UDC Sump N/A N/A



Name\ID 5/6

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Required N/A N/A



Name\ID 6 Slave

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Not Installed UDC Sump N/A N/A



Name\ID 7

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Required N/A N/A



Name\ID 7 Slave

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Not Installed UDC Sump N/A N/A



Name\ID 8

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Required N/A N/A



Name\ID 8 Slave

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Required N/A N/A

MFD Motorfuel Dispensing Forms

No Forms Found