Division of Petroleum & Chemical Safety

 

Facility Details

Facility Number: 5046834
Status: Active
Facility Name: Speedway #3961
Address: 4895 Dinius Rd.
Williamsville, IL 62693
County: Sangamon
Property Parcel: 02-32.0-400-009
Facility Type: Attended Self-Service Station
Owner Type: Private
Green Tag Decal: Y000754
Green Tag Issue Date: 2/17/2023
Green Tag Expiration Date: 12/31/2025

Owner Details

Owner Name: Speedway, LLC
Owner Address: P.O. Box 1500
Springfield, OH 45501
Owner Status: Current Owner
Purchase Date:
Type of Financial Responsibility: Commercial Insurance
Financial Responsibility Reporting Due Date: 12/13/2024

Motor Fuel Dispensing Permits

MFD Permit Type Issue Date Expiration Date
Self Service 2/17/2023 12/31/2025

Owner Summary

Click for Facility/Tank Ownership history
Owner Number Owner Name Owner Status Purchase Date
U0026552 Speedway, LLC Current Owner

Permits (Unexpired)

Click for permit history

No Active Permits Found

Deficiencies (Current)

No Deficiencies Found

IEMA Numbers Associated with the Facility

No IEMA Numbers Found

LUST Fund Eligibility and Deductibility Determinations

No Applications Found

Pay Tank Fees Online

Tank Information



Tank Number 1

Capacity: 6000 Petroleum Use:
Product: Gasoline - Premium CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 10/15/2019 Abandoned Material:
Current Age: 4 Abandoned Date:
Install Date: 5/23/2019 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date:

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Flexible Non-Corrosive N/A N/A
Corrosion Prot - Tank Fiberglass Non-Corrosive N/A N/A
Leak Detect - Piping Electronic Pressurized Line Leak Detection 9/25/2023 9/25/2024
Leak Detect - Tank Automatic Tank Gauging Incon TS 550 Evo 9/25/2023 9/25/2024
Leak Detect - Tank Non-Discriminating Interstitial Monitoring Sensors 9/25/2023 9/25/2024
Overfill Prev Device Overfill Drop Tube Valve 9/26/2022 9/26/2025
Piping Flexible Double Wall Franklin Fueling Systems UPP N/A N/A
Piping Single Wall STP/Tanktop Sump 6/9/2022 6/9/2025
Leak Detect - Piping Sump Sensor with positive shutdown 9/25/2023 9/25/2024
Spill Contain Device Single Wall Spill Bucket 6/9/2022 6/9/2025
Tank Fiberglass Double Wall Containment Solutions N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Flexible Double Wall Franklin Fueling Systems UPP Precision Test Pass 10/8/2019
Tank Fiberglass Double Wall Containment Solutions Precision Test (Tank) Pass 10/8/2019



Tank Number 2

Capacity: 6000 Petroleum Use:
Product: E85 CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 10/15/2019 Abandoned Material:
Current Age: 4 Abandoned Date:
Install Date: 5/23/2019 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date:

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Flexible Non-Corrosive N/A N/A
Corrosion Prot - Tank Fiberglass Non-Corrosive N/A N/A
Leak Detect - Piping Electronic Pressurized Line Leak Detection 9/25/2023 9/25/2024
Leak Detect - Tank Automatic Tank Gauging Incon TS 550 Evo 9/25/2023 9/25/2024
Leak Detect - Tank Non-Discriminating Interstitial Monitoring Sensors 9/25/2023 9/25/2024
Overfill Prev Device Overfill Drop Tube Valve 9/26/2022 9/26/2025
Piping Flexible Double Wall Franklin Fueling Systems UPP N/A N/A
Piping Single Wall STP/Tanktop Sump 6/9/2022 6/9/2025
Leak Detect - Piping Sump Sensor with positive shutdown 9/25/2023 9/25/2024
Spill Contain Device Single Wall Spill Bucket 6/9/2022 6/9/2025
Tank Fiberglass Double Wall Containment Solutions N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Flexible Double Wall Franklin Fueling Systems UPP Precision Test Pass 10/8/2019
Tank Fiberglass Double Wall Containment Solutions Precision Test (Tank) Pass 10/8/2019



Tank Number 3

Capacity: 12000 Petroleum Use: None
Product: B-11 CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 10/15/2019 Abandoned Material:
Current Age: 4 Abandoned Date:
Install Date: 5/23/2019 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date:

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Flexible Non-Corrosive N/A N/A
Corrosion Prot - Tank Fiberglass Non-Corrosive N/A N/A
Leak Detect - Piping Electronic Pressurized Line Leak Detection 9/25/2023 9/25/2024
Leak Detect - Tank Automatic Tank Gauging Incon TS 550 Evo 9/25/2023 9/25/2024
Leak Detect - Tank Non-Discriminating Interstitial Monitoring Sensors 9/25/2023 9/25/2024
Overfill Prev Device Overfill Drop Tube Valve 9/26/2022 9/26/2025
Piping Flexible Double Wall Franklin Fueling Systems UPP N/A N/A
Piping Single Wall STP/Tanktop Sump 6/9/2022 6/9/2025
Leak Detect - Piping Sump Sensor with positive shutdown 9/25/2023 9/25/2024
Spill Contain Device Single Wall Spill Bucket 6/9/2022 6/9/2025
Tank Fiberglass Double Wall Containment Solutions N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Flexible Double Wall Franklin Fueling Systems UPP Precision Test Pass 10/8/2019
Tank Fiberglass Double Wall Containment Solutions Precision Test (Tank) Pass 10/8/2019



Tank Number 4

Capacity: 20000 Petroleum Use:
Product: Gasoline - Regular CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 10/15/2019 Abandoned Material:
Current Age: 4 Abandoned Date:
Install Date: 5/23/2019 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date:

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Flexible Non-Corrosive N/A N/A
Corrosion Prot - Tank Fiberglass Non-Corrosive N/A N/A
Leak Detect - Piping Electronic Pressurized Line Leak Detection 9/25/2023 9/25/2024
Leak Detect - Tank Automatic Tank Gauging Incon TS 550 Evo 9/25/2023 9/25/2024
Leak Detect - Tank Non-Discriminating Interstitial Monitoring Sensors 9/25/2023 9/25/2024
Overfill Prev Device Overfill Drop Tube Valve 9/26/2022 9/26/2025
Piping Flexible Double Wall Franklin Fueling Systems UPP N/A N/A
Piping Single Wall STP/Tanktop Sump 6/9/2022 6/9/2025
Leak Detect - Piping Sump Sensor with positive shutdown 9/25/2023 9/25/2024
Spill Contain Device Single Wall Spill Bucket 6/9/2022 6/9/2025
Tank Fiberglass Double Wall Containment Solutions N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Flexible Double Wall Franklin Fueling Systems UPP Precision Test Pass 10/8/2019
Tank Fiberglass Double Wall Containment Solutions Precision Test (Tank) Pass 10/8/2019



Tank Number 5

Capacity: 20000 Petroleum Use: None
Product: B-11 CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 10/15/2019 Abandoned Material:
Current Age: 4 Abandoned Date:
Install Date: 5/23/2019 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date:

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Flexible Non-Corrosive N/A N/A
Corrosion Prot - Tank Fiberglass Non-Corrosive N/A N/A
Leak Detect - Piping Mechanical Other Non-vented check valve N/A N/A
Leak Detect - Tank Automatic Tank Gauging Incon TS 550 Evo 9/25/2023 9/25/2024
Leak Detect - Tank Non-Discriminating Interstitial Monitoring Sensors 9/25/2023 9/25/2024
Overfill Prev Device Overfill Drop Tube Valve 9/26/2022 9/26/2025
Piping Flexible Double Wall A.P.T. Poly Tech P150SC N/A N/A
Piping Steel Single Wall Piping N/A N/A
Piping Single Wall STP/Tanktop Sump 6/9/2022 6/9/2025
Leak Detect - Piping Sump Sensor with positive shutdown 9/25/2023 9/25/2024
Spill Contain Device Single Wall Spill Bucket 6/9/2022 6/9/2025
Tank Fiberglass Double Wall Containment Solutions N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Flexible Double Wall A.P.T. Poly Tech P150SC Precision Test Pass 2/17/2023
Piping Flexible Double Wall Franklin Fueling Systems UPP Precision Test Pass 10/8/2019
Piping Steel Single Wall Piping Precision Test Pass 2/17/2023
Tank Fiberglass Double Wall Containment Solutions Precision Test (Tank) Pass 10/8/2019



Tank Number 6

Capacity: 20000 Petroleum Use: None
Product: B-11 CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 10/15/2019 Abandoned Material:
Current Age: 4 Abandoned Date:
Install Date: 5/23/2019 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date:

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Flexible Non-Corrosive N/A N/A
Corrosion Prot - Tank Fiberglass Non-Corrosive N/A N/A
Leak Detect - Piping Electronic Pressurized Line Leak Detection 9/25/2023 9/25/2024
Leak Detect - Tank Automatic Tank Gauging Incon TS 550 Evo 9/25/2023 9/25/2024
Leak Detect - Tank Non-Discriminating Interstitial Monitoring Sensors 9/25/2023 9/25/2024
Overfill Prev Device Overfill Drop Tube Valve 9/26/2022 9/26/2025
Piping Flexible Double Wall Franklin Fueling Systems UPP N/A N/A
Piping Single Wall STP/Tanktop Sump 6/9/2022 6/9/2025
Leak Detect - Piping Sump Sensor with positive shutdown 9/25/2023 9/25/2024
Spill Contain Device Single Wall Spill Bucket 6/9/2022 6/9/2025
Tank Fiberglass Double Wall Containment Solutions N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Flexible Double Wall Franklin Fueling Systems UPP Precision Test Pass 10/8/2019
Tank Fiberglass Double Wall Containment Solutions Precision Test (Tank) Pass 10/8/2019



Tank Number 7

Capacity: 10000 Petroleum Use: None
Product: Diesel Exhaust Fluid (Non-Regulated) CERCLA Substance:
Status: Unknown CAS Code:
Regulated Status: Non-Regulated Removed Date:
OSFM First Notify Date: 10/15/2019 Abandoned Material:
Current Age: 4 Abandoned Date:
Install Date: 5/23/2019 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date:

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date

Dispenser Information



Name\ID 1/2

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 6/9/2022 6/9/2025
Leak Detect - Piping Sump Sensor with positive shutdown 9/25/2023 9/25/2024



Name\ID 11/12

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 6/9/2022 6/9/2025
Leak Detect - Piping Sump Sensor with positive shutdown 9/25/2023 9/25/2024



Name\ID 13/14

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 6/9/2022 6/9/2025
Leak Detect - Piping Sump Sensor with positive shutdown 9/25/2023 9/25/2024



Name\ID 15/16

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 6/9/2022 6/9/2025
Leak Detect - Piping Sump Sensor with positive shutdown 9/25/2023 9/25/2024



Name\ID 17 Satelite

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 6/9/2022 6/9/2025
Leak Detect - Piping Sump Sensor with positive shutdown 9/25/2023 9/25/2024



Name\ID 17/18

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 6/9/2022 6/9/2025
Leak Detect - Piping Sump Sensor with positive shutdown 9/25/2023 9/25/2024



Name\ID 18/19

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 6/9/2022 6/9/2025
Leak Detect - Piping Sump Sensor with positive shutdown 9/25/2023 9/25/2024



Name\ID 19 Satelite

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 6/9/2022 6/9/2025
Leak Detect - Piping Sump Sensor with positive shutdown 9/25/2023 9/25/2024



Name\ID 3/4

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 6/9/2022 6/9/2025
Leak Detect - Piping Sump Sensor with positive shutdown 9/25/2023 9/25/2024



Name\ID 5/6

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 6/9/2022 6/9/2025
Leak Detect - Piping Sump Sensor with positive shutdown 9/25/2023 9/25/2024



Name\ID 7/8

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 6/9/2022 6/9/2025
Leak Detect - Piping Sump Sensor with positive shutdown 9/25/2023 9/25/2024



Name\ID 9/10

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 6/9/2022 6/9/2025
Leak Detect - Piping Sump Sensor with positive shutdown 9/25/2023 9/25/2024

MFD Motorfuel Dispensing Forms

Facility Number Name City Received Date Letter
5046834 Speedway #3961 Williamsville 10/08/2019 Letter Form