Division of Petroleum & Chemical Safety

 

Facility Details

Facility Number: 5046190
Status: Active
Facility Name: Love's Travel Stop #687
Address: 228 Moeller Rd.
South Jacksonville, IL 62650
County: Morgan
Property Parcel: 13-05-202-001
Facility Type: Attended Self-Service Station
Owner Type: Private
Green Tag Decal: Z000511
Green Tag Issue Date: 5/13/2024
Green Tag Expiration Date: 12/31/2026

Owner Details

Owner Name: Love's Travel Stops & Country Stores, Inc.
Owner Address: 10601 N. Penn
P.O. Box 26210
Oklahoma City, OK 73120
Owner Status: Current Owner
Purchase Date:
Type of Financial Responsibility: Self-Insurance
Financial Responsibility Reporting Due Date: 6/29/2026

Motor Fuel Dispensing Permits

MFD Permit Type Issue Date Expiration Date
Self Service 5/13/2024 12/31/2026

Owner Summary

Click for Facility/Tank Ownership history
Owner Number Owner Name Owner Status Purchase Date
U0030965 Love's Travel Stops & Country Stores, Inc. Current Owner
U0032130 Love's Travel Stop & Country Stores - DO NOT USE THIS OWNER ID Former Owner

Permits (Unexpired)

Click for permit history

No Active Permits Found

Notice of Violations (Current)

No Notice of Violations Found

IEMA Numbers Associated with the Facility

No IEMA Numbers Found

LUST Fund Eligibility and Deductibility Determinations

No Applications Found

Pay Tank Fees Online

Tank Information



Tank Number 1

Capacity: 20000 Petroleum Use:
Product: Gasoline - Regular CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 12/29/2016 Abandoned Material:
Current Age: 8 Abandoned Date:
Install Date: 7/27/2016 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date:

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Fiberglass Non-Corrosive N/A N/A
Corrosion Prot - Tank Fiberglass Non-Corrosive N/A N/A
Leak Detect - Piping Electronic Pressurized Line Leak Detection 9/11/2024 9/11/2025
Leak Detect - Tank Automatic Tank Gauging Incon TS 5000 with SCALD 9/11/2024 9/11/2025
Leak Detect - Tank Non-Discriminating Interstitial Monitoring Sensors 9/11/2024 9/11/2025
Overfill Prev Device Overfill Alarm 9/28/2022 9/28/2025
Overfill Prev Device Overfill Drop Tube Valve 10/6/2022 10/6/2025
Piping Fiberglass Double Wall Ameron Dualoy 3000/LCX N/A N/A
Piping Single Wall STP/Tanktop Sump 7/28/2023 7/28/2026
Leak Detect - Piping Sump Sensor with positive shutdown 9/11/2024 9/11/2025
Spill Contain Device Double Wall Spill Bucket 7/28/2023 7/28/2026
Tank Fiberglass Double Wall XERXES N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Fiberglass Double Wall Ameron Dualoy 3000/LCX Precision Test (Piping) Pass 9/28/2022



Tank Number 2

Capacity: 12000 Petroleum Use:
Product: Diesel Fuel CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 12/29/2016 Abandoned Material:
Current Age: 8 Abandoned Date:
Install Date: 7/27/2016 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date:

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Fiberglass Non-Corrosive N/A N/A
Corrosion Prot - Tank Fiberglass Non-Corrosive N/A N/A
Leak Detect - Piping Electronic Pressurized Line Leak Detection 9/11/2024 9/11/2025
Leak Detect - Tank Automatic Tank Gauging Incon TS 5000 with SCALD 9/11/2024 9/11/2025
Leak Detect - Tank Non-Discriminating Interstitial Monitoring Sensors 9/11/2024 9/11/2025
Overfill Prev Device Overfill Alarm 9/28/2022 9/28/2025
Overfill Prev Device Overfill Drop Tube Valve 10/6/2022 10/6/2025
Piping Fiberglass Double Wall Ameron Dualoy 3000/LCX N/A N/A
Piping Single Wall STP/Tanktop Sump 7/28/2023 7/28/2026
Leak Detect - Piping Sump Sensor with positive shutdown 9/11/2024 9/11/2025
Spill Contain Device Double Wall Spill Bucket 7/28/2023 7/28/2026
Tank Fiberglass Double Wall XERXES N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Fiberglass Double Wall Ameron Dualoy 3000/LCX Precision Test (Piping) Pass 9/28/2022



Tank Number 3

Capacity: 8000 Petroleum Use:
Product: Gasoline - Premium CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 12/29/2016 Abandoned Material:
Current Age: 8 Abandoned Date:
Install Date: 7/27/2016 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date:

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Fiberglass Non-Corrosive N/A N/A
Corrosion Prot - Tank Fiberglass Non-Corrosive N/A N/A
Leak Detect - Piping Electronic Pressurized Line Leak Detection 9/11/2024 9/11/2025
Leak Detect - Tank Automatic Tank Gauging Incon TS 5000 with SCALD 9/11/2024 9/11/2025
Leak Detect - Tank Non-Discriminating Interstitial Monitoring Sensors 9/11/2024 9/11/2025
Overfill Prev Device Overfill Alarm 9/28/2022 9/28/2025
Overfill Prev Device Overfill Drop Tube Valve 9/28/2022 9/28/2025
Piping Fiberglass Double Wall Ameron Dualoy 3000/LCX N/A N/A
Piping Single Wall STP/Tanktop Sump 7/28/2023 7/28/2026
Leak Detect - Piping Sump Sensor with positive shutdown 9/11/2024 9/11/2025
Spill Contain Device Double Wall Spill Bucket 7/28/2023 7/28/2026
Tank Fiberglass Double Wall XERXES N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Fiberglass Double Wall Ameron Dualoy 3000/LCX Precision Test (Piping) Pass 9/28/2022



Tank Number 4

Capacity: 30000 Petroleum Use:
Product: Diesel Fuel CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 12/29/2016 Abandoned Material:
Current Age: 8 Abandoned Date:
Install Date: 8/4/2016 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date:

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Fiberglass Non-Corrosive N/A N/A
Corrosion Prot - Tank Fiberglass Non-Corrosive N/A N/A
Leak Detect - Piping Electronic Pressurized Line Leak Detection 10/8/2024 10/8/2025
Leak Detect - Tank Automatic Tank Gauging Incon TS 5000 with SCALD 9/11/2024 9/11/2025
Leak Detect - Tank Non-Discriminating Interstitial Monitoring Sensors 9/11/2024 9/11/2025
Overfill Prev Device Overfill Alarm 9/28/2022 9/28/2025
Overfill Prev Device Overfill Drop Tube Valve 10/6/2022 10/6/2025
Piping Fiberglass Double Wall Ameron Dualoy 3000/LCX N/A N/A
Piping Single Wall STP/Tanktop Sump 7/28/2023 7/28/2026
Leak Detect - Piping Sump Sensor with positive shutdown 9/11/2024 9/11/2025
Piping Single Wall Transition Sump 7/28/2023 7/28/2026
Leak Detect - Piping Sump Sensor with positive shutdown 9/11/2024 9/11/2025
Spill Contain Device Single Wall Spill Bucket 7/28/2023 7/28/2026
Tank Fiberglass Double Wall XERXES N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Fiberglass Double Wall Ameron Dualoy 3000/LCX Precision Test (Piping) Pass 9/28/2022



Tank Number 5

Capacity: 30000 Petroleum Use:
Product: Diesel Fuel CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 12/29/2016 Abandoned Material:
Current Age: 8 Abandoned Date:
Install Date: 8/4/2016 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date:

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Fiberglass Non-Corrosive N/A N/A
Corrosion Prot - Tank Fiberglass Non-Corrosive N/A N/A
Leak Detect - Piping Electronic Pressurized Line Leak Detection 10/8/2024 10/8/2025
Leak Detect - Tank Automatic Tank Gauging Incon TS 5000 with SCALD 9/11/2024 9/11/2025
Leak Detect - Tank Non-Discriminating Interstitial Monitoring Sensors 9/11/2024 9/11/2025
Overfill Prev Device Overfill Alarm 9/28/2022 9/28/2025
Overfill Prev Device Overfill Drop Tube Valve 10/6/2022 10/6/2025
Piping Fiberglass Double Wall Ameron Dualoy 3000/LCX N/A N/A
Piping Single Wall STP/Tanktop Sump 7/28/2023 7/28/2026
Leak Detect - Piping Sump Sensor with positive shutdown 9/11/2024 9/11/2025
Piping Single Wall Transition Sump 7/28/2023 7/28/2026
Leak Detect - Piping Sump Sensor with positive shutdown 9/11/2024 9/11/2025
Spill Contain Device Single Wall Spill Bucket 7/28/2023 7/28/2026
Tank Fiberglass Double Wall XERXES N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Fiberglass Double Wall Ameron Dualoy 3000/LCX Precision Test (Piping) Pass 6/21/2023



Tank Number 6

Capacity: 20000 Petroleum Use:
Product: B-99 CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 12/29/2016 Abandoned Material:
Current Age: 8 Abandoned Date:
Install Date: 8/4/2016 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date:

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Fiberglass Non-Corrosive N/A N/A
Corrosion Prot - Tank Fiberglass Non-Corrosive N/A N/A
Leak Detect - Piping Electronic Pressurized Line Leak Detection 9/11/2024 9/11/2025
Leak Detect - Tank Automatic Tank Gauging Incon TS 5000 with SCALD 9/11/2024 9/11/2025
Leak Detect - Tank Non-Discriminating Interstitial Monitoring Sensors 9/11/2024 9/11/2025
Overfill Prev Device Overfill Alarm 9/28/2022 9/28/2025
Overfill Prev Device Overfill Drop Tube Valve 9/28/2022 9/28/2025
Piping Fiberglass Double Wall A.O. Smith N/A N/A
Piping Single Wall STP/Tanktop Sump 7/28/2023 7/28/2026
Leak Detect - Piping Sump Sensor with positive shutdown 9/11/2024 9/11/2025
Piping Single Wall Transition Sump 7/28/2023 7/28/2026
Leak Detect - Piping Sump Sensor with positive shutdown 9/11/2024 9/11/2025
Spill Contain Device Single Wall Spill Bucket 7/28/2023 7/28/2026
Tank Fiberglass Double Wall XERXES N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Piping Fiberglass Double Wall A.O. Smith Precision Test (Piping) Pass 9/11/2024



Tank Number 7

Capacity: 20000 Petroleum Use:
Product: Diesel Exhaust Fluid (Non-Regulated) CERCLA Substance:
Status: Unknown CAS Code:
Regulated Status: Non-Regulated Removed Date:
OSFM First Notify Date: 12/29/2016 Abandoned Material:
Current Age: 8 Abandoned Date:
Install Date: 7/28/2016 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 12/1/2016

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date

Dispenser Information



Name\ID 1/2

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 7/28/2023 7/28/2026
Leak Detect - Piping Sump Sensor with positive shutdown 9/11/2024 9/11/2025



Name\ID 17M

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 7/28/2023 7/28/2026
Leak Detect - Piping Sump Sensor with positive shutdown 9/11/2024 9/11/2025



Name\ID 17S/18M

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 7/28/2023 7/28/2026
Leak Detect - Piping Sump Sensor with positive shutdown 9/11/2024 9/11/2025



Name\ID 18S/19M

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 7/28/2023 7/28/2026
Leak Detect - Piping Sump Sensor with positive shutdown 9/11/2024 9/11/2025



Name\ID 19S/20M

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 7/28/2023 7/28/2026
Leak Detect - Piping Sump Sensor with positive shutdown 9/11/2024 9/11/2025



Name\ID 20S/21M

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 7/28/2023 7/28/2026
Leak Detect - Piping Sump Sensor with positive shutdown 9/11/2024 9/11/2025



Name\ID 21S.22M

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 7/28/2023 7/28/2026
Leak Detect - Piping Sump Sensor with positive shutdown 9/11/2024 9/11/2025



Name\ID 22S

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 7/28/2023 7/28/2026
Leak Detect - Piping Sump Sensor with positive shutdown 9/11/2024 9/11/2025



Name\ID 3/4

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 7/28/2023 7/28/2026
Leak Detect - Piping Sump Sensor with positive shutdown 9/11/2024 9/11/2025



Name\ID 5/6

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 7/28/2023 7/28/2026
Leak Detect - Piping Sump Sensor with positive shutdown 9/11/2024 9/11/2025



Name\ID 7/8

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 7/28/2023 7/28/2026
Leak Detect - Piping Sump Sensor with positive shutdown 9/11/2024 9/11/2025

MFD Motorfuel Dispensing Forms

Facility Number Name City Received Date Letter
5046190 Love's Travel Stop #687 South Jacksonville 11/07/2016 Letter Form
5046190 Love's Travel Stop #687 South Jacksonville 11/07/2016 Letter Form