Division of Petroleum & Chemical Safety

 

Facility Details

Facility Number: 5043941
Status: Exempt
Facility Name: Sunrise Ag Service Co.
Address: 20735 Il. Rt. 125 P.O. Box 108 Virginia, IL 62691
County: Cass
Property Parcel:
Facility Type: Bulk Plant
Owner Type: Private
Green Tag Decal:
Green Tag Issue Date:
Green Tag Expire Date:
MFD Type: N/A

Owner Details

Owner Name: Sunrise Ag. Service Company
Owner Address: 20735 Illinois Route 125 P.O. Box 108 Virginia, IL 62691
Owner Status: Current Owner
Purchase Date:
Type of Financial Responsibility: Self-Insurance
Financial Responsibility Reporting Due Date: 9/3/2009

Owner Summary

Click for Facility/Tank Ownership history
Owner Number Owner Name Owner Status Purchase Date
U0031126 Sunrise Ag. Service Company Current Owner
U0035971 BPS Retail Fuels, Inc Former Owner 10/6/2010

Permits (Unexpired)

Click for permit history

No Active Permits Found

Notice of Violations (Current)

No Notice of Violations Found

IEMA Numbers Associated with the Facility

No IEMA Numbers Found

LUST Fund Eligibility and Deductibility Determinations

No Applications Found

Pay Tank Fees Online

Tank Information



Tank Number 1

Capacity: 20000 Petroleum Use:
Product: 100% Soy Oil (Non-Regulated) CERCLA Substance:
Status: Unknown CAS Code:
Regulated Status: Non-Regulated Removed Date:
OSFM First Notify Date: 9/3/2008 Abandoned Material:
Current Age: 17 Abandoned Date:
Install Date: 8/1/2008 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 8/1/2008

Equipment Information

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Fiberglass Non-Corrosive Not applicable Not applicable
Corrosion Prot - Tank Fiberglass Non-Corrosive Not applicable Not applicable
Leak Detect - Piping Mechanical Pressurized Line Leak Detection No passing test found No passing test found
Leak Detect - Piping Sump Sensor No passing test found No passing test found
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 350 No passing test found No passing test found
Overfill Prev Device Overfill Drop Tube Valve No passing test found No passing test found
Piping Fiberglass Double Wall Ameron Dualoy 3000/LCX Not applicable Not applicable
Spill Contain Device Single Wall Spill Bucket No passing test found No passing test found
Tank Fiberglass Single Wall Containment Solutions Not applicable Not applicable

Additional Tests

No Tests Listed


Failed test = the latest test has failed.

Not applicable = a test does not apply to this equipment type or configuration.

No passing test found = a passing test is expected but was not found from the source data.


Dispenser Information




Failed test = the latest test has failed.

Not applicable = a test does not apply to this equipment type or configuration.

No passing test found = a passing test is expected but was not found from the source data.


MFD Motorfuel Dispensing Forms

No Forms Found