Facility Details
Facility Number:
5040566
Status:
Active
Facility Name:
Murphy USA #6734
Address:
2740 North Dirksen Parkway
Springfield, IL 62702
County:
Sangamon
Property Parcel:
14-13.0-200-049
Facility Type:
Attended Self-Service Station
Owner Type:
Private
Green Tag Decal:
AA01431
Green Tag Issue Date:
1/16/2025
Green Tag Expiration Date:
12/31/2027
Owner Details
Owner Name:
Murphy Oil USA, Inc.
Owner Address:
200 E. Peach Street
El Dorado, AR 71730
Owner Status:
Current Owner
Purchase Date:
7/2/2001
Type of Financial Responsibility:
Self-Insurance
Financial Responsibility Reporting Due Date:
6/28/2025
Motor Fuel Dispensing Permits
MFD Permit Type
Issue Date
Expiration Date
Self Service
1/16/2025
12/31/2027
Owner Summary
Click for Facility/Tank Ownership history
Owner Number
Owner Name
Owner Status
Purchase Date
U0029289
Murphy Oil USA, Inc.
Current Owner
7/2/2001
Permits (Unexpired)
Click for permit history
No Active Permits Found
Notice of Violations (Current)
No Notice of Violations Found
IEMA Numbers Associated with the Facility
No IEMA Numbers Found
LUST
Fund Eligibility and Deductibility Determinations
IEMA Number
Status
OSFM Received Date
OSFM Response Date
Deductible
Letter
20170386
Eligible
7/14/2017
7/18/2017
$5,000
Letter
Pay Tank Fees Online
Tank Information
Tank Number 1
Capacity:
7000
Petroleum Use:
Product:
Gasoline - Premium
CERCLA Substance:
Status:
Currently in use
CAS Code:
Regulated Status:
Federal
Removed Date:
OSFM
First Notify Date:
9/5/2001
Abandoned Material:
Current Age:
23
Abandoned Date:
Install Date:
7/27/2001
Red Tag Issue Date:
Last Used Date:
Fee Due:
$0.00
Product Date:
9/10/2001
Equipment
Equipment Type
Equipment
Last Passing Date
Test Expire Date
Corrosion Prot - Piping
Flexible Non-Corrosive
N/A
N/A
Corrosion Prot - Tank
Fiberglass Non-Corrosive
N/A
N/A
Leak Detect - Piping
Mechanical Pressurized Line Leak Detection
7/18/2024
7/18/2025
Leak Detect - Tank
Automatic Tank Gauging Veeder Root TLS 350 with CSLD
11/1/2024
11/1/2025
Leak Detect - Tank
Non-Discriminating Interstitial Monitoring Sensors
8/8/2024
8/8/2025
Overfill Prev Device
Overfill Drop Tube Valve
7/18/2024
7/18/2027
Piping
Flexible Double Wall Environ Geo Flex
N/A
N/A
Piping
Single Wall STP/Tanktop Sump
1/26/2024
1/26/2027
Leak Detect - Piping
Sump Sensor
7/18/2024
7/18/2025
Spill Contain Device
Single Wall Spill Bucket
8/3/2023
8/3/2026
Tank
Fiberglass Double Wall XERXES
N/A
N/A
Vent, Riser, Fill Piping
Steel risers
N/A
N/A
Additional Tests
Equipment Type
Equipment
Test Type
Test Result
Test Date
Piping
Flexible Double Wall Environ Geo Flex
Precision Test (Piping)
Pass
7/18/2024
Tank Number 2
Capacity:
14000
Petroleum Use:
Product:
Gasoline - Regular
CERCLA Substance:
Status:
Currently in use
CAS Code:
Regulated Status:
Federal
Removed Date:
OSFM
First Notify Date:
9/5/2001
Abandoned Material:
Current Age:
23
Abandoned Date:
Install Date:
7/27/2001
Red Tag Issue Date:
Last Used Date:
Fee Due:
$0.00
Product Date:
9/10/2001
Equipment
Equipment Type
Equipment
Last Passing Date
Test Expire Date
Corrosion Prot - Piping
Flexible Non-Corrosive
N/A
N/A
Corrosion Prot - Tank
Fiberglass Non-Corrosive
N/A
N/A
Leak Detect - Piping
Mechanical Pressurized Line Leak Detection
11/1/2024
11/1/2025
Leak Detect - Tank
Automatic Tank Gauging Veeder Root TLS 350 with CSLD
11/1/2024
11/1/2025
Leak Detect - Tank
Non-Discriminating Interstitial Monitoring Sensors
8/8/2024
8/8/2025
Overfill Prev Device
Overfill Drop Tube Valve
10/1/2024
10/1/2027
Piping
Flexible Double Wall Environ Geo Flex
N/A
N/A
Piping
Single Wall STP/Tanktop Sump
9/22/2023
9/22/2026
Leak Detect - Piping
Sump Sensor
7/18/2024
7/18/2025
Spill Contain Device
Double Wall Spill Bucket
10/1/2024
10/1/2027
Tank
Fiberglass Double Wall XERXES
N/A
N/A
Vent, Riser, Fill Piping
Steel risers
N/A
N/A
Additional Tests
Equipment Type
Equipment
Test Type
Test Result
Test Date
Piping
Flexible Double Wall Environ Geo Flex
Precision Test (Piping)
Pass
7/18/2024
Tank Number 3
Capacity:
7000
Petroleum Use:
Product:
Diesel Fuel
CERCLA Substance:
Status:
Currently in use
CAS Code:
Regulated Status:
Federal
Removed Date:
OSFM
First Notify Date:
9/5/2001
Abandoned Material:
Current Age:
23
Abandoned Date:
Install Date:
7/27/2001
Red Tag Issue Date:
Last Used Date:
Fee Due:
$0.00
Product Date:
9/10/2001
Equipment
Equipment Type
Equipment
Last Passing Date
Test Expire Date
Corrosion Prot - Piping
Flexible Non-Corrosive
N/A
N/A
Corrosion Prot - Tank
Fiberglass Non-Corrosive
N/A
N/A
Leak Detect - Piping
Mechanical Pressurized Line Leak Detection
7/18/2024
7/18/2025
Leak Detect - Tank
Automatic Tank Gauging Veeder Root TLS 350 with CSLD
11/1/2024
11/1/2025
Leak Detect - Tank
Non-Discriminating Interstitial Monitoring Sensors
7/18/2024
7/18/2025
Overfill Prev Device
Overfill Drop Tube Valve
7/18/2024
7/18/2027
Piping
Flexible Double Wall Environ Geo Flex
N/A
N/A
Piping
Single Wall STP/Tanktop Sump
11/1/2024
11/1/2027
Leak Detect - Piping
Sump Sensor
7/18/2024
7/18/2025
Spill Contain Device
Single Wall Spill Bucket
8/8/2024
8/8/2027
Tank
Fiberglass Double Wall XERXES
N/A
N/A
Vent, Riser, Fill Piping
Steel risers
N/A
N/A
Additional Tests
Equipment Type
Equipment
Test Type
Test Result
Test Date
Piping
Flexible Double Wall Environ Geo Flex
Precision Test (Piping)
Pass
7/18/2024
Tank Number 4
Capacity:
14000
Petroleum Use:
Product:
Gasoline - Regular
CERCLA Substance:
Status:
Currently in use
CAS Code:
Regulated Status:
Federal
Removed Date:
OSFM
First Notify Date:
9/5/2001
Abandoned Material:
Current Age:
23
Abandoned Date:
Install Date:
7/27/2001
Red Tag Issue Date:
Last Used Date:
Fee Due:
$0.00
Product Date:
9/10/2001
Equipment
Equipment Type
Equipment
Last Passing Date
Test Expire Date
Corrosion Prot - Piping
Flexible Non-Corrosive
N/A
N/A
Corrosion Prot - Tank
Fiberglass Non-Corrosive
N/A
N/A
Leak Detect - Piping
Mechanical Pressurized Line Leak Detection
11/1/2024
11/1/2025
Leak Detect - Tank
Automatic Tank Gauging Veeder Root TLS 350 with CSLD
11/1/2024
11/1/2025
Leak Detect - Tank
Non-Discriminating Interstitial Monitoring Sensors
7/18/2024
7/18/2025
Overfill Prev Device
Overfill Drop Tube Valve
7/18/2024
7/18/2027
Piping
Flexible Double Wall Environ Geo Flex
N/A
N/A
Piping
Single Wall STP/Tanktop Sump
9/22/2023
9/22/2026
Leak Detect - Piping
Sump Sensor
7/18/2024
7/18/2025
Spill Contain Device
Double Wall Spill Bucket
11/16/2023
11/16/2026
Tank
Fiberglass Double Wall XERXES
N/A
N/A
Vent, Riser, Fill Piping
Steel risers
N/A
N/A
Additional Tests
Equipment Type
Equipment
Test Type
Test Result
Test Date
Piping
Flexible Double Wall Environ Geo Flex
Precision Test (Piping)
Pass
7/18/2024
Dispenser Information
Name\ID 1/2
Status:
Active
Equipment Type
Equipment
Last Passing Date
Test Expire Date
Dispenser
Single Wall UDC Sump
9/22/2023
9/22/2026
Leak Detect - Piping
Sump Sensor
7/18/2024
7/18/2025
Name\ID 3/4
Status:
Active
Equipment Type
Equipment
Last Passing Date
Test Expire Date
Dispenser
Single Wall UDC Sump
9/22/2023
9/22/2026
Leak Detect - Piping
Sump Sensor
7/18/2024
7/18/2025
Name\ID 5/6
Status:
Active
Equipment Type
Equipment
Last Passing Date
Test Expire Date
Dispenser
Single Wall UDC Sump
9/22/2023
9/22/2026
Leak Detect - Piping
Sump Sensor
7/18/2024
7/18/2025
Name\ID 7/8
Status:
Active
Equipment Type
Equipment
Last Passing Date
Test Expire Date
Dispenser
Single Wall UDC Sump
9/22/2023
9/22/2026
Leak Detect - Piping
Sump Sensor
7/18/2024
7/18/2025
MFD
Motorfuel Dispensing Forms
No Forms Found