Division of Petroleum & Chemical Safety

 

Facility Details

Facility Number: 5039109
Status: Active
Facility Name: Meijer Store #176
Address: 2700 Prairie Crossing Drive Springfield, IL 62711
County: Sangamon
Property Parcel: 22-19.0-104-001
Facility Type: Attended Self-Service Station
Owner Type: Private
Green Tag Decal: Z000531
Green Tag Issue Date: 6/11/2024
Green Tag Expiration Date: 12/31/2026

Owner Details

Owner Name: Meijer Great Lakes Limited Partnership
Owner Address: 2929 Walker Avenue, NW Grand Rapids, MI 495449428
Owner Status: Current Owner
Purchase Date: 11/5/1999
Type of Financial Responsibility: Self-Insurance
Financial Responsibility Reporting Due Date: 11/2/2026

Motor Fuel Dispensing Permits

MFD Permit Type Issue Date Expiration Date
Self Service 6/11/2024 12/31/2026

Owner Summary

Click for Facility/Tank Ownership history
Owner Number Owner Name Owner Status Purchase Date
U0023695 Meijer Great Lakes Limited Partnership Current Owner 11/5/1999

Permits (Unexpired)

Click for permit history

No Active Permits Found

Notice of Violatlions (Current)

NOV Number: E0020252961 (Pending)    Issue Date: 11/5/2025    Expiration Date: 1/4/2026    View NOV Form

Tanks Violations
5 Line leak detection equipment in alarm or failed test, must repair or replace. - Sump sensor failed test 9/4/2025.

IEMA Numbers Associated with the Facility

No IEMA Numbers Found

LUST Fund Eligibility and Deductibility Determinations

No Applications Found

Pay Tank Fees Online

Tank Information



Tank Number 1

Capacity: 9000 Petroleum Use:
Product: Gasoline - Regular CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 3/30/2000 Abandoned Material:
Current Age: 25 Abandoned Date:
Install Date: 11/5/1999 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 3/15/2000

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Fiberglass Non-Corrosive N/A N/A
Corrosion Prot - Tank Fiberglass Non-Corrosive N/A N/A
Leak Detect - Piping Siphon Bar N/A N/A
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 350 9/4/2025 9/4/2026
Leak Detect - Tank Hydrostatic Reservoir Interstitial Monitoring Sensors 9/4/2025 9/4/2026
Overfill Prev Device Overfill Alarm 11/25/2024 11/25/2027
Overfill Prev Device Overfill Drop Tube Valve 9/23/2024 9/23/2027
Piping Fiberglass Double Wall Ameron N/A N/A
Piping Single Wall STP/Tanktop Sump 10/30/2024 10/30/2027
Leak Detect - Piping Sump Sensor 9/4/2025 9/4/2026
Spill Contain Device Single Wall Spill Bucket 10/30/2024 10/30/2027
Tank Fiberglass Brine Filled Double Wall XERXES N/A N/A
Vent, Riser, Fill Piping Steel risers N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date
Leak Detect - Piping Siphon Bar Functional Pass 9/23/2024



Tank Number 2

Capacity: 8000 Petroleum Use:
Product: Gasoline - Regular CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 3/30/2000 Abandoned Material:
Current Age: 25 Abandoned Date:
Install Date: 11/5/1999 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 3/15/2000

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Fiberglass Non-Corrosive N/A N/A
Corrosion Prot - Tank Fiberglass Non-Corrosive N/A N/A
Leak Detect - Piping Electronic Pressurized Line Leak Detection 9/4/2025 9/4/2026
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 350 9/4/2025 9/4/2026
Leak Detect - Tank Hydrostatic Reservoir Interstitial Monitoring Sensors 9/4/2025 9/4/2026
Overfill Prev Device Overfill Alarm 11/25/2024 11/25/2027
Overfill Prev Device Overfill Drop Tube Valve 9/23/2024 9/23/2027
Piping Fiberglass Double Wall Ameron N/A N/A
Piping Single Wall STP/Tanktop Sump 10/30/2024 10/30/2027
Leak Detect - Piping Sump Sensor 9/4/2025 9/4/2026
Spill Contain Device Single Wall Spill Bucket 10/30/2024 10/30/2027
Tank Fiberglass Brine Filled Double Wall XERXES N/A N/A
Vent, Riser, Fill Piping Steel risers N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date



Tank Number 3

Capacity: 9000 Petroleum Use:
Product: Gasoline - Premium CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 3/30/2000 Abandoned Material:
Current Age: 25 Abandoned Date:
Install Date: 11/5/1999 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 3/15/2000

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Fiberglass Non-Corrosive N/A N/A
Corrosion Prot - Tank Fiberglass Non-Corrosive N/A N/A
Leak Detect - Piping Electronic Pressurized Line Leak Detection 9/4/2025 9/4/2026
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 350 9/4/2025 9/4/2026
Leak Detect - Tank Hydrostatic Reservoir Interstitial Monitoring Sensors 9/4/2025 9/4/2026
Overfill Prev Device Overfill Alarm 11/25/2024 11/25/2027
Overfill Prev Device Overfill Drop Tube Valve 9/23/2024 9/23/2027
Piping Fiberglass Double Wall Ameron N/A N/A
Piping Single Wall STP/Tanktop Sump 10/30/2024 10/30/2027
Leak Detect - Piping Sump Sensor 9/23/2024 9/23/2025
Leak Detect - Piping Sump Sensor with positive shutdown 9/4/2025 9/4/2026
Spill Contain Device Single Wall Spill Bucket 10/30/2024 10/30/2027
Tank Fiberglass Brine Filled Double Wall XERXES N/A N/A
Vent, Riser, Fill Piping Steel risers N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date



Tank Number 4

Capacity: 6000 Petroleum Use:
Product: Diesel Fuel CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 3/30/2000 Abandoned Material:
Current Age: 25 Abandoned Date:
Install Date: 11/5/1999 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 3/15/2000

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Fiberglass Non-Corrosive N/A N/A
Corrosion Prot - Tank Fiberglass Non-Corrosive N/A N/A
Leak Detect - Piping Electronic Pressurized Line Leak Detection 9/4/2025 9/4/2026
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 350 9/4/2025 9/4/2026
Leak Detect - Tank Hydrostatic Reservoir Interstitial Monitoring Sensors 9/4/2025 9/4/2026
Overfill Prev Device Overfill Alarm 11/25/2024 11/25/2027
Overfill Prev Device Overfill Drop Tube Valve 9/23/2024 9/23/2027
Piping Fiberglass Double Wall Ameron N/A N/A
Piping Single Wall STP/Tanktop Sump 10/30/2024 10/30/2027
Leak Detect - Piping Non-Discriminating Sump Sensor 12/10/2019 12/10/2020
Leak Detect - Piping Sump Sensor 9/4/2025 9/4/2026
Spill Contain Device Single Wall Spill Bucket 10/30/2024 10/30/2027
Tank Fiberglass Brine Filled Double Wall XERXES N/A N/A
Vent, Riser, Fill Piping Steel risers N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date



Tank Number 5

Capacity: 3000 Petroleum Use:
Product: Gasoline - Non Ethanol CERCLA Substance:
Status: Currently in use CAS Code:
Regulated Status: Federal Removed Date:
OSFM First Notify Date: 3/30/2000 Abandoned Material:
Current Age: 25 Abandoned Date:
Install Date: 11/5/1999 Red Tag Issue Date:
Last Used Date: Fee Due: $0.00
Product Date: 3/15/2000

Equipment

Equipment Type Equipment Last Passing Date Test Expire Date
Corrosion Prot - Piping Fiberglass Non-Corrosive N/A N/A
Corrosion Prot - Tank Fiberglass Non-Corrosive N/A N/A
Leak Detect - Piping Electronic Pressurized Line Leak Detection 11/11/2025 11/11/2026
Leak Detect - Tank Automatic Tank Gauging Veeder Root TLS 350 9/4/2025 9/4/2026
Leak Detect - Tank Hydrostatic Reservoir Interstitial Monitoring Sensors 9/4/2025 9/4/2026
Overfill Prev Device Overfill Alarm 11/25/2024 11/25/2027
Overfill Prev Device Overfill Drop Tube Valve 10/17/2024 10/17/2027
Piping Fiberglass Double Wall Ameron N/A N/A
Piping Single Wall STP/Tanktop Sump 10/30/2024 10/30/2027
Leak Detect - Piping Sump Sensor 9/23/2024 9/4/2025
Spill Contain Device Single Wall Spill Bucket 10/30/2024 10/30/2027
Tank Fiberglass Brine Filled Double Wall XERXES N/A N/A
Vent, Riser, Fill Piping Steel risers N/A N/A

Additional Tests

Equipment Type Equipment Test Type Test Result Test Date

Dispenser Information



Name\ID 1/2

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Required N/A N/A



Name\ID 11/12

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump 10/30/2024 10/30/2027
Leak Detect - Piping Sump Sensor with positive shutdown 9/4/2025 9/4/2026



Name\ID 3/4

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Required N/A N/A



Name\ID 5/6

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Required N/A N/A



Name\ID 7/8

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Required N/A N/A



Name\ID 9/10

Status: Active
Equipment Type Equipment Last Passing Date Test Expire Date
Dispenser Single Wall UDC Sump
Leak Detect - Piping Piping Sump Sensors Not Regulated Not Required N/A N/A

MFD Motorfuel Dispensing Forms

No Forms Found