Owner Summary
Click for Facility/Tank Ownership history
| Owner Number |
Owner Name |
Owner Status |
Purchase Date |
| U0030116 |
Bluejay Junction, Inc. |
Current Owner |
8/31/1998 |
| U0005466 |
Freesen, Inc. |
Former Owner |
3/1/1988 |
Permits (Unexpired)
Click for permit history
| Permit Number |
Type |
Status |
OSFM Receive Date |
Issue Date |
Expiration Date |
Documents |
| 00858-2026INS |
Install |
Approved / Issued |
7/16/2026 |
7/22/2026 |
1/22/2027 |
Documents |
| 00854-2026REM |
Removal |
Approved / Issued |
7/22/2026 |
7/22/2026 |
1/22/2027 |
Documents |
Notice of Violations (Current)
No Notice of Violations Found
IEMA Numbers Associated with the Facility
| IEMA Number |
Inspection Date |
Inspection Type |
Permit Number |
| 2026-0611 |
8/5/2026 |
Removal Log |
00854-2026REM |
| 2026-0611 |
8/6/2026 |
Removal Log |
00854-2026REM |
LUST
Fund Eligibility and Deductibility Determinations
| IEMA Number |
Status |
OSFM Received Date |
OSFM Response Date |
Deductible |
Letter |
| 20260611 |
Eligible |
9/15/2026
|
10/2/2026
|
$5,000
|
Letter
|
Tank Number 1
| Capacity: |
10000 |
|
Petroleum Use: |
|
| Product: |
Gasoline - Regular |
|
CERCLA Substance: |
|
| Status: |
Removed |
|
CAS Code: |
|
| Regulated Status: |
Federal |
|
Removed Date: |
8/5/2026 |
|
OSFM
First Notify Date: |
4/27/1995 |
|
Abandoned Material: |
|
| Current Age: |
38 |
|
Abandoned Date: |
|
| Install Date: |
3/28/1988 |
|
Red Tag Issue Date: |
|
| Last Used Date: |
8/15/2023 |
|
Fee Due: |
$0.00 |
| Product Date: |
3/28/1988 |
|
|
|
Equipment Information
| Equipment Type |
Equipment |
Last Passing Date |
Test Expire Date |
|
Corrosion Prot - Piping
|
Isolation Boots Flex Connector |
Not applicable |
Not applicable |
|
Corrosion Prot - Piping
|
Fiberglass Non-Corrosive |
Not applicable |
Not applicable |
|
Corrosion Prot - Tank
|
Impressed Current Cathodic Protection |
5/3/2024 |
5/3/2025 |
|
Leak Detect - Piping
|
Mechanical Pressurized Line Leak Detection |
5/12/2023 |
5/12/2024 |
|
Leak Detect - Tank
|
Automatic Tank Gauging Veeder Root TLS 350 with CSLD |
5/12/2023 |
5/12/2024 |
|
Overfill Prev Device
|
Overfill Drop Tube Valve |
5/12/2022 |
5/12/2025 |
|
Piping
|
Flex Connector Steel |
Not applicable |
Not applicable |
|
Piping
|
Fiberglass Single Wall Piping |
Not applicable |
Not applicable |
|
Piping
|
Not Installed STP/Tanktop Sump |
Not applicable |
Not applicable |
Leak Detect - Piping
|
Piping Sump Sensors Not Regulated Not Required |
Not applicable |
Not applicable |
|
Spill Contain Device
|
Single Wall Spill Bucket |
5/12/2022 |
5/12/2025 |
|
Tank
|
Steel Single Wall |
Not applicable |
Not applicable |
|
Vent, Riser, Fill Piping
|
Steel risers |
Not applicable |
Not applicable |
Additional Tests
| Equipment Type |
Equipment |
Test Type |
Test Result |
Test Date |
|
Piping
|
Fiberglass Single Wall Piping
|
Precision Test (Piping)
|
Pass
|
5/12/2023
|
Tank Number 2
| Capacity: |
10000 |
|
Petroleum Use: |
|
| Product: |
Gasoline - Premium |
|
CERCLA Substance: |
|
| Status: |
Removed |
|
CAS Code: |
|
| Regulated Status: |
Federal |
|
Removed Date: |
8/6/2026 |
|
OSFM
First Notify Date: |
4/27/1995 |
|
Abandoned Material: |
|
| Current Age: |
38 |
|
Abandoned Date: |
|
| Install Date: |
3/28/1988 |
|
Red Tag Issue Date: |
|
| Last Used Date: |
|
|
Fee Due: |
$0.00 |
| Product Date: |
3/28/1988 |
|
|
|
Equipment Information
| Equipment Type |
Equipment |
Last Passing Date |
Test Expire Date |
|
Corrosion Prot - Piping
|
Isolation Boots Flex Connector |
Not applicable |
Not applicable |
|
Corrosion Prot - Piping
|
Fiberglass Non-Corrosive |
Not applicable |
Not applicable |
|
Corrosion Prot - Tank
|
Impressed Current Cathodic Protection |
5/7/2026 |
5/7/2027 |
|
Leak Detect - Piping
|
Mechanical Pressurized Line Leak Detection |
5/7/2026 |
5/7/2027 |
|
Leak Detect - Tank
|
Automatic Tank Gauging Veeder Root TLS 350 with CSLD |
5/7/2026 |
5/7/2027 |
|
Overfill Prev Device
|
Overfill Drop Tube Valve |
5/8/2025 |
5/8/2028 |
|
Piping
|
Flex Connector Steel |
Not applicable |
Not applicable |
|
Piping
|
Fiberglass Single Wall Piping |
Not applicable |
Not applicable |
|
Piping
|
Not Installed STP/Tanktop Sump |
Not applicable |
Not applicable |
Leak Detect - Piping
|
Piping Sump Sensors Not Regulated Not Required |
Not applicable |
Not applicable |
|
Spill Contain Device
|
Single Wall Spill Bucket |
5/8/2025 |
5/8/2028 |
|
Tank
|
Steel Single Wall |
Not applicable |
Not applicable |
|
Vent, Riser, Fill Piping
|
Steel risers |
Not applicable |
Not applicable |
Additional Tests
| Equipment Type |
Equipment |
Test Type |
Test Result |
Test Date |
|
Piping
|
Fiberglass Single Wall Piping
|
Precision Test (Piping)
|
Pass
|
5/7/2026
|
Tank Number 3
| Capacity: |
10000 |
|
Petroleum Use: |
None |
| Product: |
Diesel Fuel |
|
CERCLA Substance: |
|
| Status: |
Removed |
|
CAS Code: |
|
| Regulated Status: |
Federal |
|
Removed Date: |
8/6/2026 |
|
OSFM
First Notify Date: |
4/27/1995 |
|
Abandoned Material: |
|
| Current Age: |
38 |
|
Abandoned Date: |
|
| Install Date: |
3/28/1988 |
|
Red Tag Issue Date: |
|
| Last Used Date: |
|
|
Fee Due: |
$0.00 |
| Product Date: |
3/28/1988 |
|
|
|
Equipment Information
| Equipment Type |
Equipment |
Last Passing Date |
Test Expire Date |
|
Corrosion Prot - Piping
|
Isolation Boots Flex Connector |
Not applicable |
Not applicable |
|
Corrosion Prot - Piping
|
Sacrificial Anode Flex Connector |
5/8/2025 |
5/8/2028 |
|
Corrosion Prot - Piping
|
Fiberglass Non-Corrosive |
Not applicable |
Not applicable |
|
Corrosion Prot - Tank
|
Impressed Current Cathodic Protection |
5/7/2026 |
5/7/2027 |
|
Leak Detect - Piping
|
Mechanical Pressurized Line Leak Detection |
5/7/2026 |
5/7/2027 |
|
Leak Detect - Tank
|
Automatic Tank Gauging Veeder Root TLS 350 with CSLD |
5/7/2026 |
5/7/2027 |
|
Overfill Prev Device
|
Overfill Drop Tube Valve |
5/8/2025 |
5/8/2028 |
|
Piping
|
Flex Connector Steel |
Not applicable |
Not applicable |
|
Piping
|
Fiberglass Single Wall Piping |
Not applicable |
Not applicable |
|
Piping
|
Not Installed STP/Tanktop Sump |
Not applicable |
Not applicable |
Leak Detect - Piping
|
Piping Sump Sensors Not Regulated Not Required |
Not applicable |
Not applicable |
|
Spill Contain Device
|
Single Wall Spill Bucket |
5/8/2025 |
5/8/2028 |
|
Tank
|
Steel Single Wall |
Not applicable |
Not applicable |
|
Vent, Riser, Fill Piping
|
Steel risers |
Not applicable |
Not applicable |
Additional Tests
| Equipment Type |
Equipment |
Test Type |
Test Result |
Test Date |
|
Piping
|
Fiberglass Single Wall Piping
|
Precision Test (Piping)
|
Pass
|
5/7/2026
|
Tank Number 4
| Capacity: |
4000 |
|
Petroleum Use: |
None |
| Product: |
Diesel Fuel |
|
CERCLA Substance: |
|
| Status: |
Removed |
|
CAS Code: |
|
| Regulated Status: |
Federal |
|
Removed Date: |
8/5/2026 |
|
OSFM
First Notify Date: |
4/27/1995 |
|
Abandoned Material: |
|
| Current Age: |
38 |
|
Abandoned Date: |
|
| Install Date: |
3/28/1988 |
|
Red Tag Issue Date: |
|
| Last Used Date: |
|
|
Fee Due: |
$0.00 |
| Product Date: |
3/28/1988 |
|
|
|
Equipment Information
| Equipment Type |
Equipment |
Last Passing Date |
Test Expire Date |
|
Corrosion Prot - Piping
|
Isolation Boots Flex Connector |
Not applicable |
Not applicable |
|
Corrosion Prot - Piping
|
Sacrificial Anode Flex Connector |
5/8/2025 |
5/8/2028 |
|
Corrosion Prot - Piping
|
Fiberglass Non-Corrosive |
Not applicable |
Not applicable |
|
Corrosion Prot - Tank
|
Impressed Current Cathodic Protection |
5/7/2026 |
5/7/2027 |
|
Leak Detect - Piping
|
Mechanical Pressurized Line Leak Detection |
5/7/2026 |
5/7/2027 |
|
Leak Detect - Tank
|
Automatic Tank Gauging Veeder Root TLS 350 with CSLD |
5/7/2026 |
5/7/2027 |
|
Overfill Prev Device
|
Overfill Drop Tube Valve |
5/8/2025 |
5/8/2028 |
|
Piping
|
Flex Connector Steel |
Not applicable |
Not applicable |
|
Piping
|
Fiberglass Single Wall Piping |
Not applicable |
Not applicable |
|
Piping
|
Not Installed STP/Tanktop Sump |
Not applicable |
Not applicable |
Leak Detect - Piping
|
Piping Sump Sensors Not Regulated Not Required |
Not applicable |
Not applicable |
|
Spill Contain Device
|
Single Wall Spill Bucket |
5/8/2025 |
5/8/2028 |
|
Tank
|
Steel Single Wall |
Not applicable |
Not applicable |
|
Vent, Riser, Fill Piping
|
Steel risers |
Not applicable |
Not applicable |
Additional Tests
| Equipment Type |
Equipment |
Test Type |
Test Result |
Test Date |
|
Piping
|
Fiberglass Single Wall Piping
|
Precision Test (Piping)
|
Pass
|
5/7/2026
|
Tank Number 5
| Capacity: |
2000 |
|
Petroleum Use: |
|
| Product: |
Gasoline - Non Ethanol |
|
CERCLA Substance: |
|
| Status: |
Removed |
|
CAS Code: |
|
| Regulated Status: |
Federal |
|
Removed Date: |
8/5/2026 |
|
OSFM
First Notify Date: |
4/27/1995 |
|
Abandoned Material: |
|
| Current Age: |
38 |
|
Abandoned Date: |
|
| Install Date: |
3/28/1988 |
|
Red Tag Issue Date: |
|
| Last Used Date: |
|
|
Fee Due: |
$0.00 |
| Product Date: |
3/28/1988 |
|
|
|
Equipment Information
| Equipment Type |
Equipment |
Last Passing Date |
Test Expire Date |
|
Corrosion Prot - Piping
|
Isolation Boots Flex Connector |
Not applicable |
Not applicable |
|
Corrosion Prot - Piping
|
Fiberglass Non-Corrosive |
Not applicable |
Not applicable |
|
Corrosion Prot - Tank
|
Impressed Current Cathodic Protection |
5/7/2026 |
5/7/2027 |
|
Leak Detect - Piping
|
Mechanical Pressurized Line Leak Detection |
5/7/2026 |
5/7/2027 |
|
Leak Detect - Tank
|
Automatic Tank Gauging Veeder Root TLS 350 with CSLD |
5/7/2026 |
5/7/2027 |
|
Overfill Prev Device
|
Overfill Drop Tube Valve |
5/8/2025 |
5/8/2028 |
|
Piping
|
Flex Connector Steel |
Not applicable |
Not applicable |
|
Piping
|
Fiberglass Single Wall Piping |
Not applicable |
Not applicable |
|
Piping
|
Not Installed STP/Tanktop Sump |
Not applicable |
Not applicable |
Leak Detect - Piping
|
Piping Sump Sensors Not Regulated Not Required |
Not applicable |
Not applicable |
|
Spill Contain Device
|
Single Wall Spill Bucket |
5/8/2025 |
5/8/2028 |
|
Tank
|
Steel Single Wall |
Not applicable |
Not applicable |
|
Vent, Riser, Fill Piping
|
Steel risers |
Not applicable |
Not applicable |
Additional Tests
| Equipment Type |
Equipment |
Test Type |
Test Result |
Test Date |
|
Piping
|
Fiberglass Single Wall Piping
|
Precision Test (Piping)
|
Pass
|
5/7/2026
|
Tank Number 6
| Capacity: |
10000 |
|
Petroleum Use: |
|
| Product: |
Gasoline - Regular |
|
CERCLA Substance: |
|
| Status: |
Currently in use |
|
CAS Code: |
|
| Regulated Status: |
Federal |
|
Removed Date: |
|
|
OSFM
First Notify Date: |
9/8/2026 |
|
Abandoned Material: |
|
| Current Age: |
0 |
|
Abandoned Date: |
|
| Install Date: |
8/18/2026 |
|
Red Tag Issue Date: |
|
| Last Used Date: |
|
|
Fee Due: |
$0.00 |
| Product Date: |
|
|
|
|
Equipment Information
| Equipment Type |
Equipment |
Last Passing Date |
Test Expire Date |
|
Corrosion Prot - Piping
|
Fiberglass Non-Corrosive |
Not applicable |
Not applicable |
|
Corrosion Prot - Tank
|
Fiberglass Non-Corrosive |
Not applicable |
Not applicable |
|
Leak Detect - Piping
|
Mechanical Pressurized Line Leak Detection |
9/25/2026 |
9/25/2027 |
|
Leak Detect - Tank
|
Non-Discriminating Interstitial Monitoring Sensors |
9/25/2026 |
9/25/2027 |
|
Overfill Prev Device
|
Overfill Drop Tube Valve |
9/25/2026 |
9/25/2029 |
|
Piping
|
Fiberglass Double Wall Ameron Dualoy 3000/LCX |
Not applicable |
Not applicable |
|
Piping
|
Flex Connector Steel |
Not applicable |
Not applicable |
|
Piping
|
Fiberglass Single Wall Piping Ameron Dualoy 3000/L |
Not applicable |
Not applicable |
|
Piping
|
Single Wall STP/Tanktop Sump |
9/2/2026 |
9/2/2029 |
Leak Detect - Piping
|
Sump Sensor with positive shutdown |
9/2/2026 |
9/2/2029 |
|
Piping
|
Tank Steel Riser |
Not applicable |
Not applicable |
|
Piping
|
Extractor Fitting Valves |
Not applicable |
Not applicable |
|
Spill Contain Device
|
Double Wall Spill Bucket |
9/2/2026 |
9/2/2029 |
|
Tank
|
Fiberglass Double Wall KBK Industries |
Not applicable |
Not applicable |
Additional Tests
| Equipment Type |
Equipment |
Test Type |
Test Result |
Test Date |
|
Piping
|
Fiberglass Double Wall Ameron Dualoy 3000/LCX
|
Precision Test (Piping)
|
Pass
|
9/25/2026
|
|
Piping
|
Fiberglass Single Wall Piping Ameron Dualoy 3000/L
|
Precision Test (Piping)
|
Pass
|
9/25/2026
|
|
Piping
|
Tank Steel Riser
|
Precision Test (Piping)
|
Pass
|
9/25/2026
|
|
Tank
|
Fiberglass Double Wall KBK Industries
|
Precision Test (Tank)
|
Pass
|
9/25/2026
|
Tank Number 7
| Capacity: |
8000 |
|
Petroleum Use: |
Consumptive Use on Premises for Heating |
| Product: |
Diesel Fuel |
|
CERCLA Substance: |
|
| Status: |
Currently in use |
|
CAS Code: |
|
| Regulated Status: |
Federal |
|
Removed Date: |
|
|
OSFM
First Notify Date: |
9/8/2026 |
|
Abandoned Material: |
|
| Current Age: |
0 |
|
Abandoned Date: |
|
| Install Date: |
8/18/2026 |
|
Red Tag Issue Date: |
|
| Last Used Date: |
|
|
Fee Due: |
$0.00 |
| Product Date: |
|
|
|
|
Equipment Information
| Equipment Type |
Equipment |
Last Passing Date |
Test Expire Date |
|
Corrosion Prot - Piping
|
Fiberglass Non-Corrosive |
Not applicable |
Not applicable |
|
Corrosion Prot - Tank
|
Fiberglass Non-Corrosive |
Not applicable |
Not applicable |
|
Leak Detect - Piping
|
Mechanical Pressurized Line Leak Detection |
9/25/2026 |
9/25/2027 |
|
Leak Detect - Tank
|
Non-Discriminating Interstitial Monitoring Sensors |
9/25/2026 |
9/25/2027 |
|
Overfill Prev Device
|
Overfill Drop Tube Valve |
9/25/2026 |
9/25/2029 |
|
Piping
|
Fiberglass Double Wall Ameron Dualoy 3000/LCX |
Not applicable |
Not applicable |
|
Piping
|
Flex Connector Steel |
Not applicable |
Not applicable |
|
Piping
|
Fiberglass Single Wall Piping Ameron Dualoy 3000/L |
Not applicable |
Not applicable |
|
Piping
|
Single Wall STP/Tanktop Sump |
9/2/2026 |
9/2/2029 |
Leak Detect - Piping
|
Sump Sensor with positive shutdown |
9/2/2026 |
9/2/2029 |
|
Piping
|
Tank Steel Riser |
Not applicable |
Not applicable |
|
Piping
|
Extractor Fitting Valves |
Not applicable |
Not applicable |
|
Spill Contain Device
|
Double Wall Spill Bucket |
9/2/2026 |
9/2/2029 |
|
Tank
|
Fiberglass Double Wall KBK Industries |
Not applicable |
Not applicable |
Additional Tests
| Equipment Type |
Equipment |
Test Type |
Test Result |
Test Date |
|
Piping
|
Fiberglass Double Wall Ameron Dualoy 3000/LCX
|
Precision Test (Piping)
|
Pass
|
9/25/2026
|
|
Piping
|
Fiberglass Single Wall Piping Ameron Dualoy 3000/L
|
Precision Test (Piping)
|
Pass
|
9/25/2026
|
|
Piping
|
Tank Steel Riser
|
Precision Test (Piping)
|
Pass
|
9/25/2026
|
|
Tank
|
Fiberglass Double Wall KBK Industries
|
Precision Test (Tank)
|
Pass
|
9/25/2026
|
Tank Number 8
| Capacity: |
4000 |
|
Petroleum Use: |
Dispensing |
| Product: |
Diesel Fuel |
|
CERCLA Substance: |
|
| Status: |
Currently in use |
|
CAS Code: |
|
| Regulated Status: |
Federal |
|
Removed Date: |
|
|
OSFM
First Notify Date: |
9/8/2026 |
|
Abandoned Material: |
|
| Current Age: |
0 |
|
Abandoned Date: |
|
| Install Date: |
8/18/2026 |
|
Red Tag Issue Date: |
|
| Last Used Date: |
|
|
Fee Due: |
$0.00 |
| Product Date: |
|
|
|
|
Equipment Information
| Equipment Type |
Equipment |
Last Passing Date |
Test Expire Date |
|
Corrosion Prot - Piping
|
Fiberglass Non-Corrosive |
Not applicable |
Not applicable |
|
Corrosion Prot - Tank
|
Fiberglass Non-Corrosive |
Not applicable |
Not applicable |
|
Leak Detect - Piping
|
Mechanical Pressurized Line Leak Detection |
9/25/2026 |
9/25/2027 |
|
Leak Detect - Tank
|
Non-Discriminating Interstitial Monitoring Sensors |
9/25/2026 |
9/25/2027 |
|
Overfill Prev Device
|
Overfill Drop Tube Valve |
9/25/2026 |
9/25/2029 |
|
Piping
|
Fiberglass Double Wall Ameron Dualoy 3000/LCX |
Not applicable |
Not applicable |
|
Piping
|
Flex Connector Steel |
Not applicable |
Not applicable |
|
Piping
|
Fiberglass Single Wall Piping Ameron Dualoy 3000/L |
Not applicable |
Not applicable |
|
Piping
|
Single Wall STP/Tanktop Sump |
9/2/2026 |
9/2/2029 |
Leak Detect - Piping
|
Sump Sensor with positive shutdown |
9/2/2026 |
9/2/2029 |
|
Piping
|
Tank Steel Riser |
Not applicable |
Not applicable |
|
Piping
|
Extractor Fitting Valves |
Not applicable |
Not applicable |
|
Spill Contain Device
|
Double Wall Spill Bucket |
9/2/2026 |
9/2/2029 |
|
Tank
|
Fiberglass Double Wall KBK Industries |
Not applicable |
Not applicable |
Additional Tests
| Equipment Type |
Equipment |
Test Type |
Test Result |
Test Date |
|
Piping
|
Fiberglass Double Wall Ameron Dualoy 3000/LCX
|
Precision Test (Piping)
|
Pass
|
9/25/2026
|
|
Piping
|
Fiberglass Single Wall Piping Ameron Dualoy 3000/L
|
Precision Test (Piping)
|
Pass
|
9/25/2026
|
|
Piping
|
Tank Steel Riser
|
Precision Test (Piping)
|
Pass
|
9/25/2026
|
|
Tank
|
Fiberglass Double Wall KBK Industries
|
Precision Test (Tank)
|
Pass
|
9/25/2026
|
Tank Number 9
| Capacity: |
6000 |
|
Petroleum Use: |
|
| Product: |
Gasoline - Non Ethanol |
|
CERCLA Substance: |
|
| Status: |
Currently in use |
|
CAS Code: |
|
| Regulated Status: |
Federal |
|
Removed Date: |
|
|
OSFM
First Notify Date: |
9/8/2026 |
|
Abandoned Material: |
|
| Current Age: |
0 |
|
Abandoned Date: |
|
| Install Date: |
8/18/2026 |
|
Red Tag Issue Date: |
|
| Last Used Date: |
|
|
Fee Due: |
$0.00 |
| Product Date: |
|
|
|
|
Equipment Information
| Equipment Type |
Equipment |
Last Passing Date |
Test Expire Date |
|
Corrosion Prot - Piping
|
Fiberglass Non-Corrosive |
Not applicable |
Not applicable |
|
Corrosion Prot - Tank
|
Fiberglass Non-Corrosive |
Not applicable |
Not applicable |
|
Leak Detect - Piping
|
Mechanical Pressurized Line Leak Detection |
9/25/2026 |
9/25/2027 |
|
Leak Detect - Tank
|
Non-Discriminating Interstitial Monitoring Sensors |
9/25/2026 |
9/25/2027 |
|
Overfill Prev Device
|
Overfill Drop Tube Valve |
9/25/2026 |
9/25/2029 |
|
Piping
|
Fiberglass Double Wall Ameron Dualoy 3000/LCX |
Not applicable |
Not applicable |
|
Piping
|
Flex Connector Steel |
Not applicable |
Not applicable |
|
Piping
|
Fiberglass Single Wall Piping Ameron Dualoy 3000/L |
Not applicable |
Not applicable |
|
Piping
|
Single Wall STP/Tanktop Sump |
9/2/2026 |
9/2/2029 |
Leak Detect - Piping
|
Sump Sensor with positive shutdown |
9/2/2026 |
9/2/2029 |
|
Piping
|
Tank Steel Riser |
Not applicable |
Not applicable |
|
Piping
|
Extractor Fitting Valves |
Not applicable |
Not applicable |
|
Spill Contain Device
|
Double Wall Spill Bucket |
9/2/2026 |
9/2/2029 |
|
Tank
|
Fiberglass Double Wall KBK Industries |
Not applicable |
Not applicable |
Additional Tests
| Equipment Type |
Equipment |
Test Type |
Test Result |
Test Date |
|
Piping
|
Fiberglass Double Wall Ameron Dualoy 3000/LCX
|
Precision Test (Piping)
|
Pass
|
9/25/2026
|
|
Piping
|
Fiberglass Single Wall Piping Ameron Dualoy 3000/L
|
Precision Test (Piping)
|
Pass
|
9/25/2026
|
|
Piping
|
Tank Steel Riser
|
Precision Test (Piping)
|
Pass
|
9/25/2026
|
|
Tank
|
Fiberglass Double Wall KBK Industries
|
Precision Test (Tank)
|
Pass
|
9/25/2026
|
Failed test = the latest test has failed.
Not applicable = a test does not apply to this equipment type or configuration.
No passing test found = a passing test is expected but was not found from the source data.
Dispenser Information
Name\ID 1/2
| Status: |
Active |
|
| Equipment Type |
Equipment |
Last Passing Date |
Test Expire Date |
|
Dispenser
|
Single Wall UDC Sump |
9/2/2026
|
9/2/2029
|
Leak Detect - Piping
|
Sump Sensor with positive shutdown |
9/25/2026
|
9/25/2027
|
Name\ID 3/4
| Status: |
Active |
|
| Equipment Type |
Equipment |
Last Passing Date |
Test Expire Date |
|
Dispenser
|
Single Wall UDC Sump |
9/2/2026
|
9/2/2029
|
Leak Detect - Piping
|
Sump Sensor with positive shutdown |
9/25/2026
|
9/25/2027
|
Name\ID 5/6
| Status: |
Active |
|
| Equipment Type |
Equipment |
Last Passing Date |
Test Expire Date |
|
Dispenser
|
Single Wall UDC Sump |
9/2/2026
|
9/2/2029
|
Leak Detect - Piping
|
Sump Sensor with positive shutdown |
9/25/2026
|
9/25/2027
|
Failed test = the latest test has failed.
Not applicable = a test does not apply to this equipment type or configuration.
No passing test found = a passing test is expected but was not found from the source data.
MFD
Motorfuel Dispensing Forms
| Facility Number |
Name |
City |
Received Date |
Letter |
|
5034052
|
Bluejay Junction, Inc.
|
Bluffs
|
07/16/2026
|
Letter
Form
|